The Use of Ultrasound-Measured Optic Nerve Sheath Diameter to Predict Ventriculoperitoneal Shunt Failure in Children

被引:18
|
作者
Lin, Sophia D. [1 ,2 ]
Kahne, Kimberly R. [3 ]
El Sherif, Amira [3 ]
Mennitt, Kevin [4 ]
Kessler, David [5 ]
Ward, Mary J. [3 ]
Platt, Shari L. [2 ]
机构
[1] Weill Cornell Med Coll, Dept Med, Div Emergency Med, New York, NY USA
[2] Weill Cornell Med Coll, Dept Pediat, Div Pediat Emergency Med, New York, NY USA
[3] Weill Cornell Med Coll, Dept Pediat, New York, NY USA
[4] Weill Cornell Med Coll, Dept Radiol, New York, NY USA
[5] Columbia Coll Phys & Surg, Dept Pediat, Div Pediat Emergency Med, New York, NY USA
关键词
bedside ultrasound; pediatric shunt failure; optic nerve sheath diameter; RAISED INTRACRANIAL-PRESSURE; SONOGRAPHIC MEASUREMENT; COMPUTED-TOMOGRAPHY; SUBARACHNOID SPACE; OCULAR ULTRASOUND; ULTRASONOGRAPHY; HYPERTENSION; ACCURACY; MRI;
D O I
10.1097/PEC.0000000000001034
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective The goal of this study was to assess the accuracy of ultrasound-measured optic nerve sheath diameter (ONSD) as a screen for ventriculoperitoneal shunt failure. Methods We prospectively enrolled a convenience sample of children presenting to the ED with suspected shunt failure. The ONSD was measured by ultrasound and compared with computed tomography/magnetic resonance imaging (CT/MRI) and neurosurgical impression. We defined shunt failure on ultrasound as an ONSD greater than 4.0 mm in infants 12 months and younger or greater than 4.5 mm in children older than 12 months. A single emergency radiologist at our institution read all CTs and MRIs for categorical determination of shunt failure. We defined shunt failure based on neurosurgical impression as a decision to admit and perform shunt revision. We report test characteristics and 95% confidence intervals of ONSD as a predictor for shunt failure. Results We enrolled 32 subjects. The sensitivities of ONSD compared with CT/MRI and neurosurgical impression, 60.0% and 75.0%, respectively, were low. However, the negative predictive values of ONSD compared with CT/MRI and neurosurgical impression were 90.0% and 95.0%, respectively. Conclusions Optic nerve sonography may be a useful tool to identify children presenting with suspected ventriculoperitoneal shunt failure who do not require further imaging. This would reduce the use of CT scan and exposure to ionizing radiation in children with suspected shunt malfunction who do not require neurosurgical intervention. Consideration of additional risk factors and a larger sample size may yield stronger results.
引用
收藏
页码:268 / 272
页数:5
相关论文
共 50 条
  • [31] Optic nerve sheath diameter in children with acute liver failure and hepatic encephalopathy
    Suresh, Varun
    Aggarwal, Anurag
    LIVER INTERNATIONAL, 2021, 41 (01) : 233 - 233
  • [32] Optic nerve sheath diameter measured by point-of-care ocular ultrasound in glaucoma patients
    Kilic, Turgay Yilmaz
    Eyler, Yesim
    Ozen, Bediz
    Yuce, Berna
    Yesilaras, Murat
    Atilla, Ozge Duman
    ANNALS OF CLINICAL AND ANALYTICAL MEDICINE, 2022, 13 (06): : 630 - 634
  • [33] EFFECT OF CERVICAL SYMPATHETIC BLOCK ON OPTIC NERVE SHEATH DIAMETER MEASURED BY ULTRASONOGRAPHY
    Kim, Min-Soo
    Yoon, Kyung Bong
    Yoon, Duck Mi
    Kim, Do-Hyeong
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (06) : 1599 - 1604
  • [34] Prognostic significance of the optic nerve sheath diameter in acute respiratory failure
    Efgan, Mehmet Goktug
    Karakaya, Zeynep
    Yamanoglu, Adnan
    Kayali, Ahmet
    CUKUROVA MEDICAL JOURNAL, 2022, 47 (03): : 1187 - 1196
  • [35] Discussion: Nocturnal Ultrasound Measurements of Optic Nerve Sheath Diameter Correlate with Intracranial Pressure in Children with Craniosynostosis
    Nischal, Ken K.
    Smith, Darren M.
    Losee, Joseph E.
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2012, 130 (03) : 452E - 454E
  • [36] A Unique Model for Ultrasound Assessment of Optic Nerve Sheath Diameter
    Zeiler, Frederick A.
    Unger, Bertram
    Kramer, Andreas H.
    Kirkpatrick, Andrew W.
    Gillman, Lawrence M.
    CANADIAN JOURNAL OF NEUROLOGICAL SCIENCES, 2013, 40 (02) : 225 - 229
  • [37] Correlation between optic nerve sheath diameter measured on imaging with acute pathologies found on computed tomography of trauma patients
    Jenjitranant, Pinporn
    Tunlayadechanont, Padcha
    Prachanukool, Thidathit
    Kaewlai, Rathachai
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 125
  • [38] Effects of prone positioning with neck extension on intracranial pressure according to optic nerve sheath diameter measured using ultrasound in children
    Soo-Bin Yoon
    Sang-Hwan Ji
    Young-Eun Jang
    Ji-Hyun Lee
    Eun-Hee Kim
    Jin-Tae Kim
    Hee-Soo Kim
    Child's Nervous System, 2020, 36 : 1001 - 1007
  • [39] Optic Nerve Sheath Diameter Ultrasound: Optic Nerve Growth Curve and Its Application to Detect Intracranial Hypertension in Children
    Fontanel, Liviana
    Pensiero, Stefano
    Ronfani, Luca
    Rosolen, Valentina
    Barbi, Egidio
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2019, 208 : 421 - 428
  • [40] Normal Sonographic Optic Nerve Sheath Diameter among Children in South Western Nigeria
    Olatunji, Ayodeji Anike
    Bodunde, Olubunmi O.
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2019, 13 (01) : TC18 - TC20