The Use of Ultrasound-Measured Optic Nerve Sheath Diameter to Predict Ventriculoperitoneal Shunt Failure in Children

被引:18
|
作者
Lin, Sophia D. [1 ,2 ]
Kahne, Kimberly R. [3 ]
El Sherif, Amira [3 ]
Mennitt, Kevin [4 ]
Kessler, David [5 ]
Ward, Mary J. [3 ]
Platt, Shari L. [2 ]
机构
[1] Weill Cornell Med Coll, Dept Med, Div Emergency Med, New York, NY USA
[2] Weill Cornell Med Coll, Dept Pediat, Div Pediat Emergency Med, New York, NY USA
[3] Weill Cornell Med Coll, Dept Pediat, New York, NY USA
[4] Weill Cornell Med Coll, Dept Radiol, New York, NY USA
[5] Columbia Coll Phys & Surg, Dept Pediat, Div Pediat Emergency Med, New York, NY USA
关键词
bedside ultrasound; pediatric shunt failure; optic nerve sheath diameter; RAISED INTRACRANIAL-PRESSURE; SONOGRAPHIC MEASUREMENT; COMPUTED-TOMOGRAPHY; SUBARACHNOID SPACE; OCULAR ULTRASOUND; ULTRASONOGRAPHY; HYPERTENSION; ACCURACY; MRI;
D O I
10.1097/PEC.0000000000001034
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective The goal of this study was to assess the accuracy of ultrasound-measured optic nerve sheath diameter (ONSD) as a screen for ventriculoperitoneal shunt failure. Methods We prospectively enrolled a convenience sample of children presenting to the ED with suspected shunt failure. The ONSD was measured by ultrasound and compared with computed tomography/magnetic resonance imaging (CT/MRI) and neurosurgical impression. We defined shunt failure on ultrasound as an ONSD greater than 4.0 mm in infants 12 months and younger or greater than 4.5 mm in children older than 12 months. A single emergency radiologist at our institution read all CTs and MRIs for categorical determination of shunt failure. We defined shunt failure based on neurosurgical impression as a decision to admit and perform shunt revision. We report test characteristics and 95% confidence intervals of ONSD as a predictor for shunt failure. Results We enrolled 32 subjects. The sensitivities of ONSD compared with CT/MRI and neurosurgical impression, 60.0% and 75.0%, respectively, were low. However, the negative predictive values of ONSD compared with CT/MRI and neurosurgical impression were 90.0% and 95.0%, respectively. Conclusions Optic nerve sonography may be a useful tool to identify children presenting with suspected ventriculoperitoneal shunt failure who do not require further imaging. This would reduce the use of CT scan and exposure to ionizing radiation in children with suspected shunt malfunction who do not require neurosurgical intervention. Consideration of additional risk factors and a larger sample size may yield stronger results.
引用
收藏
页码:268 / 272
页数:5
相关论文
共 50 条
  • [21] Optic nerve sheath diameter ultrasound measurement to evaluate cerebral edema in children with diabetic ketoacidosis
    De Bernardo, Maddalena
    Vitiello, Livio
    Rosa, Nicola
    JOURNAL OF PEDIATRIC ENDOCRINOLOGY & METABOLISM, 2019, 32 (11) : 1205 - 1206
  • [22] Determination of ventriculoperitoneal shunt dysfunction using optic nerve sheath diameter measurement on CT scan in pediatric patients with hydrocephalus
    Aydin Ozturk, Pinar
    Asena, Muhammet
    CHILDS NERVOUS SYSTEM, 2021, 37 (06) : 1895 - 1900
  • [23] Determination of ventriculoperitoneal shunt dysfunction using optic nerve sheath diameter measurement on CT scan in pediatric patients with hydrocephalus
    Pınar Aydin Ozturk
    Muhammet Asena
    Child's Nervous System, 2021, 37 : 1895 - 1900
  • [24] Optic nerve sheath diameter as a criterion for endoscopic third ventriculostomy failure in children
    Rolando Jiménez-Guerra
    Child's Nervous System, 2015, 31 : 1217 - 1218
  • [25] Bedside measurement of the optic nerve sheath diameter with ultrasound in cerebrovascular disorders
    Yuzbasioglu, Yucel
    Yuzbasioglu, Sema
    Coskun, Selcuk
    Icme, Ferhat
    Oz, Tolga
    Kunt, Refik
    Becel, Sinan
    Akcay, Emine
    Kavakli, Havva Sahin
    TURKISH JOURNAL OF MEDICAL SCIENCES, 2018, 48 (01) : 93 - 99
  • [26] Ocular ultrasound evaluation of optic nerve sheath diameter in military environments
    De Bernardo, Maddalena
    Vitiello, Livio
    Cornetta, Palmiro
    Rosa, Nicola
    MILITARY MEDICAL RESEARCH, 2019, 6 (1)
  • [27] Ocular Ultrasound Abnormalities and Optic Nerve Sheath Diameter in Dogs and Cats
    Cho, Jane
    VETERINARY CLINICS OF NORTH AMERICA-SMALL ANIMAL PRACTICE, 2021, 51 (06) : 1295 - 1314
  • [28] Measurement of optic nerve sheath diameter by ultrasound in healthy term neonates
    Lan, Shih-Yun
    Tai, Hung-Lin
    Lin, Jainn-Jim
    Lan, Fan-Yun
    Tsai, Hsin-Yu
    Lin, Kuang-Lin
    PEDIATRICS AND NEONATOLOGY, 2021, 62 (06) : 591 - 597
  • [29] Ultrasound measurement of the optic nerve sheath diameter in traumatic brain injury: a narrative review
    Natile, M.
    Simonet, O.
    Vallot, F.
    De Kock, M.
    ACTA ANAESTHESIOLOGICA BELGICA, 2021, 72 (04) : 151 - 168
  • [30] A-scan ultrasonography and optic nerve sheath diameter evaluation in children with acute liver failure
    De Bernardo, Maddalena
    Vitiello, Livio
    Capone, Michela
    Rosa, Nicola
    LIVER INTERNATIONAL, 2020, 40 (06) : 1504 - 1504