The Use of Ultrasound-Measured Optic Nerve Sheath Diameter to Predict Ventriculoperitoneal Shunt Failure in Children

被引:18
|
作者
Lin, Sophia D. [1 ,2 ]
Kahne, Kimberly R. [3 ]
El Sherif, Amira [3 ]
Mennitt, Kevin [4 ]
Kessler, David [5 ]
Ward, Mary J. [3 ]
Platt, Shari L. [2 ]
机构
[1] Weill Cornell Med Coll, Dept Med, Div Emergency Med, New York, NY USA
[2] Weill Cornell Med Coll, Dept Pediat, Div Pediat Emergency Med, New York, NY USA
[3] Weill Cornell Med Coll, Dept Pediat, New York, NY USA
[4] Weill Cornell Med Coll, Dept Radiol, New York, NY USA
[5] Columbia Coll Phys & Surg, Dept Pediat, Div Pediat Emergency Med, New York, NY USA
关键词
bedside ultrasound; pediatric shunt failure; optic nerve sheath diameter; RAISED INTRACRANIAL-PRESSURE; SONOGRAPHIC MEASUREMENT; COMPUTED-TOMOGRAPHY; SUBARACHNOID SPACE; OCULAR ULTRASOUND; ULTRASONOGRAPHY; HYPERTENSION; ACCURACY; MRI;
D O I
10.1097/PEC.0000000000001034
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective The goal of this study was to assess the accuracy of ultrasound-measured optic nerve sheath diameter (ONSD) as a screen for ventriculoperitoneal shunt failure. Methods We prospectively enrolled a convenience sample of children presenting to the ED with suspected shunt failure. The ONSD was measured by ultrasound and compared with computed tomography/magnetic resonance imaging (CT/MRI) and neurosurgical impression. We defined shunt failure on ultrasound as an ONSD greater than 4.0 mm in infants 12 months and younger or greater than 4.5 mm in children older than 12 months. A single emergency radiologist at our institution read all CTs and MRIs for categorical determination of shunt failure. We defined shunt failure based on neurosurgical impression as a decision to admit and perform shunt revision. We report test characteristics and 95% confidence intervals of ONSD as a predictor for shunt failure. Results We enrolled 32 subjects. The sensitivities of ONSD compared with CT/MRI and neurosurgical impression, 60.0% and 75.0%, respectively, were low. However, the negative predictive values of ONSD compared with CT/MRI and neurosurgical impression were 90.0% and 95.0%, respectively. Conclusions Optic nerve sonography may be a useful tool to identify children presenting with suspected ventriculoperitoneal shunt failure who do not require further imaging. This would reduce the use of CT scan and exposure to ionizing radiation in children with suspected shunt malfunction who do not require neurosurgical intervention. Consideration of additional risk factors and a larger sample size may yield stronger results.
引用
收藏
页码:268 / 272
页数:5
相关论文
共 50 条
  • [1] Ultrasound-measured optic nerve sheath diameter correlates well with cerebrospinal fluid pressure
    Gupta, Salil
    Pachisia, Aditya
    NEUROLOGY INDIA, 2019, 67 (03) : 772 - 776
  • [2] Bedside optic nerve sheath diameter ultrasound for the evaluation of suspected pediatric ventriculoperitoneal shunt failure in the emergency department
    Hall, M. Kennedy
    Spiro, David M.
    Sabbaj, Alfredo
    Moore, Christopher L.
    Hopkins, Katharine L.
    Meckler, Garth D.
    CHILDS NERVOUS SYSTEM, 2013, 29 (12) : 2275 - 2280
  • [3] Point-of-care ultrasound of optic nerve sheath diameter to detect intracranial pressure in neurocritically ill children - A narrative review
    Lin, Jainn-Jim
    Chen, Aaron E.
    Lin, Elaina E.
    Hsia, Shao-Hsuan
    Chiang, Ming-Chou
    Lin, Kuang-Lin
    BIOMEDICAL JOURNAL, 2020, 43 (03) : 231 - 239
  • [4] Ultrasound measurement of optic nerve diameter and optic nerve sheath diameter in healthy Chinese adults
    Chen, Han
    Ding, Gui-Sheng
    Zhao, Yan-Chun
    Yu, Rong-Guo
    Zhou, Jian-Xin
    BMC NEUROLOGY, 2015, 15
  • [5] The relationship between transorbital ultrasound measurement of the optic nerve sheath diameter (ONSD) and invasively measured ICP in children.
    Padayachy, Llewellyn C.
    Padayachy, Vaishali
    Galal, Ushma
    Pollock, Travis
    Fieggen, A. Graham
    CHILDS NERVOUS SYSTEM, 2016, 32 (10) : 1779 - 1785
  • [6] Optic nerve sheath diameter in children with acute liver failure: A prospective observational pilot study
    Das, Mridul C.
    Srivastava, Anshu
    Yadav, Rajanikant K.
    Yachha, Surender K.
    Poddar, Ujjal
    LIVER INTERNATIONAL, 2020, 40 (02) : 428 - 436
  • [7] ACCURACY OF OPTIC NERVE SHEATH DIAMETER MEASUREMENT BY EMERGENCY PHYSICIANS USING BEDSIDE ULTRASOUND
    Hassen, Getaw Worku
    Bruck, Isaac
    Donahue, Joseph
    Mason, Benjamin
    Sweeney, Brett
    Saab, Weafue
    Weedon, Jeremy
    Patel, Neal
    Perry, Kenneth
    Matari, Hussein
    Jaiswal, Rajnish
    Kalantari, Hossein
    JOURNAL OF EMERGENCY MEDICINE, 2015, 48 (04): : 450 - 457
  • [8] Measurement of changes in optic nerve sheath diameter using ultrasound and computed tomography scan before and after the ventriculoperitoneal shunt surgery in patients with hydrocephalus-A prospective observational trial
    Bhandari, Deepak
    Bidkar, Prasanna Udupi
    Adinarayanan, S.
    Narmadhalakshmi, K.
    Srinivasan, S.
    BRITISH JOURNAL OF NEUROSURGERY, 2019, 33 (02) : 125 - 130
  • [9] Ultrasound assessment of optic nerve sheath diameter in healthy volunteers
    Goeres, Patrick
    Zeiler, Frederick A.
    Unger, Bertram
    Karakitsos, Dimitrios
    Gillman, Lawrence M.
    JOURNAL OF CRITICAL CARE, 2016, 31 (01) : 168 - 171
  • [10] Ultrasound Options for Measuring Optic Nerve Sheath Diameter in Children
    Capasso, Luigi
    De Bernardo, Maddalena
    Vitiello, Livio
    Rosa, Nicola
    PEDIATRIC CRITICAL CARE MEDICINE, 2021, 22 (05) : E326 - E327