IRIS-HSVD algorithm for automatic quantitation of in vivo 31P MRS

被引:5
|
作者
Wang, Xin [1 ]
Lee, Jing-Huei [1 ,2 ]
机构
[1] Univ Cincinnati, Dept Biomed Engn, Cincinnati, OH 45267 USA
[2] Univ Cincinnati, Ctr Imaging Res, Cincinnati, OH 45267 USA
关键词
Magnetic resonance spectroscopy; Quantification; Hankel singular value decomposition; Iteration; Automation; P-31; MAGNETIC-RESONANCE-SPECTROSCOPY; SINGULAR-VALUE DECOMPOSITION; GRAPHICAL USER-INTERFACE; TIME-DOMAIN; PRIOR KNOWLEDGE; PARAMETER-ESTIMATION; NMR-SPECTROSCOPY; LEAST-SQUARES; QUANTIFICATION; SIGNALS;
D O I
10.1016/j.jmr.2008.09.024
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The rapid development of P-31 magnetic resonance spectroscopy (MRS) has enhanced non-invasive measurement of brain metabolites, which is important for biomedical research. The accuracy and efficiency of data post processing and quantification is paramount for MRS applications. One of the difficulties with in vivo P-31 MRS data quantification is the separation of broad line-width resonances from chemical compounds' resonances under a low signal-to-noise ratio condition. Furthermore, the chemical shift of some compounds caused by pH and Mg2+ concentration can be troublesome. This work aims to develop an automatic algorithm Using a state-space based quantification approach to solve the above mentioned problems. To achieve this aim, we utilized an HSVD based adaptive optimizing prior knowledge algorithm, which uses so called "interference" signals to optimize prior knowledge iteratively for parameter optimization. We termed this algorithm IRIS-HSVD, which stands for Iterative Reduction of Interference Signal HSVD. The Monte Carlo evaluations of the algorithm were conducted with simulated data using in vivo parameters commonly obtained from a 4 T scanner. The performance of this algorithm using simulated data was compared to those of other automatic methods including HSVD and HTLS-PK. Examples of in vivo P-31 data obtained from brains of healthy subjects on a 4T MRI scanner were also presented, which demonstrated the superiority of the new method. The results were compared with those using AMARES. (C) 2008 Elsevier Inc. All rights reserved.
引用
收藏
页码:23 / 32
页数:10
相关论文
共 50 条
  • [31] On neglecting chemical exchange effects when correcting in vivo 31P MRS data for partial saturation
    Ouwerkerk, R
    Bottomley, PA
    JOURNAL OF MAGNETIC RESONANCE, 2001, 148 (02) : 425 - 435
  • [32] Absolute quantification of phosphorus metabolite concentrations in human muscle in vivo by 31P MRS:: a quantitative review
    Kemp, Graham J.
    Meyerspeer, Martin
    Moser, Ewald
    NMR IN BIOMEDICINE, 2007, 20 (06) : 555 - 565
  • [33] The magnitude of signal errors introduced by ISIS in quantitative 31P MRS
    Ljungberg, M
    Starck, G
    Vikhoff-Baaz, B
    Alpsten, M
    Ekholm, S
    Forssell-Aronsson, E
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2002, 14 (01): : 30 - 38
  • [34] Cardiac transplant patients response to the 31P MRS stress test
    Evanochko, WT
    Buchthal, SD
    den Hollander, JA
    Katholi, CR
    Bourge, RC
    Benza, RL
    Kirklin, JK
    Pohost, GM
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2002, 21 (05): : 522 - 529
  • [35] Intracellular Redox State Revealed by In Vivo 31P MRS Measurement of NAD+ and NADH Contents in Brains
    Lu, Ming
    Zhu, Xiao-Hong
    Zhang, Yi
    Chen, Wei
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (06) : 1959 - 1972
  • [36] Potential of MRI and 31P MRS in the evaluation of experimental testicular trauma
    Srinivas, M
    Degaonkar, M
    Chandrasekharam, VVSS
    Gupta, DK
    Hemal, AK
    Shariff, A
    Jagannathan, NR
    UROLOGY, 2002, 59 (06) : 969 - 972
  • [37] 31P MRS STUDIES OF BIOENERGETICS IN SCHIZOPHRENIA: IMPLICATIONS FOR SYNAPTIC FUNCTION
    Ongur, Dost
    SCHIZOPHRENIA BULLETIN, 2017, 43 : S91 - S91
  • [38] Investigating the effect of trigger delay on cardiac 31P MRS signals
    Stefan Wampl
    Tito Körner
    Ladislav Valkovič
    Siegfried Trattnig
    Michael Wolzt
    Martin Meyerspeer
    Albrecht Ingo Schmid
    Scientific Reports, 11
  • [39] Investigating the effect of trigger delay on cardiac 31P MRS signals
    Wampl, Stefan
    Koerner, Tito
    Valkovic, Ladislav
    Trattnig, Siegfried
    Wolzt, Michael
    Meyerspeer, Martin
    Schmid, Albrecht Ingo
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [40] Evidence of Altered Neuropil Development in ADHD Children: A Longitudinal In Vivo 31P MRS Study at 3 Tesla
    Stanley, Jeffrey A.
    Wu, Helen
    Goradia, Dhruman D.
    Khatib, Dalal
    Rajan, Usha
    Burgess, Ashley
    Robin, Arthor L.
    Rosenberg, David R.
    BIOLOGICAL PSYCHIATRY, 2015, 77 (09) : 108S - 108S