IRIS-HSVD algorithm for automatic quantitation of in vivo 31P MRS

被引:5
|
作者
Wang, Xin [1 ]
Lee, Jing-Huei [1 ,2 ]
机构
[1] Univ Cincinnati, Dept Biomed Engn, Cincinnati, OH 45267 USA
[2] Univ Cincinnati, Ctr Imaging Res, Cincinnati, OH 45267 USA
关键词
Magnetic resonance spectroscopy; Quantification; Hankel singular value decomposition; Iteration; Automation; P-31; MAGNETIC-RESONANCE-SPECTROSCOPY; SINGULAR-VALUE DECOMPOSITION; GRAPHICAL USER-INTERFACE; TIME-DOMAIN; PRIOR KNOWLEDGE; PARAMETER-ESTIMATION; NMR-SPECTROSCOPY; LEAST-SQUARES; QUANTIFICATION; SIGNALS;
D O I
10.1016/j.jmr.2008.09.024
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The rapid development of P-31 magnetic resonance spectroscopy (MRS) has enhanced non-invasive measurement of brain metabolites, which is important for biomedical research. The accuracy and efficiency of data post processing and quantification is paramount for MRS applications. One of the difficulties with in vivo P-31 MRS data quantification is the separation of broad line-width resonances from chemical compounds' resonances under a low signal-to-noise ratio condition. Furthermore, the chemical shift of some compounds caused by pH and Mg2+ concentration can be troublesome. This work aims to develop an automatic algorithm Using a state-space based quantification approach to solve the above mentioned problems. To achieve this aim, we utilized an HSVD based adaptive optimizing prior knowledge algorithm, which uses so called "interference" signals to optimize prior knowledge iteratively for parameter optimization. We termed this algorithm IRIS-HSVD, which stands for Iterative Reduction of Interference Signal HSVD. The Monte Carlo evaluations of the algorithm were conducted with simulated data using in vivo parameters commonly obtained from a 4 T scanner. The performance of this algorithm using simulated data was compared to those of other automatic methods including HSVD and HTLS-PK. Examples of in vivo P-31 data obtained from brains of healthy subjects on a 4T MRI scanner were also presented, which demonstrated the superiority of the new method. The results were compared with those using AMARES. (C) 2008 Elsevier Inc. All rights reserved.
引用
收藏
页码:23 / 32
页数:10
相关论文
共 50 条
  • [1] IRIS-HSVD for automatic MRS data quantification
    Wang, Xin
    Lee, Jing-Huei
    2008 CANADIAN CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING, VOLS 1-4, 2008, : 1749 - 1752
  • [2] In vivo 31p MRS of experimental tumours
    de, Certaines, J.D.
    Larsen, V.A.
    Podo, F.
    Carpinelli, G.
    Briot, O.
    Henriksen, O.
    NMR in Biomedicine, 1993, 6 (06)
  • [3] Classification of 31P MRS for Liver Cancer in vivo
    Sang, Jun
    Liu, Yihui
    Liu, Qiang
    Li, Baopeng
    Cheng, Jinyong
    2009 FOURTH INTERNATIONAL CONFERENCE ON BIO-INSPIRED COMPUTING: THEORIES AND APPLICATIONS, PROCEEDINGS, 2009, : 108 - +
  • [4] Use of computer simulations for quantitation of 31P ISIS MRS results
    Matson, G.B.
    Meyerhoff, D.J.
    Lawry, T.J.
    Lara, R.S.
    Duijn, J.
    Deicken, R.F.
    Weiner, M.W.
    NMR in Biomedicine, 1993, 6 (03)
  • [5] In vivo cardiac 31P MRS in a mouse model of heart failure
    Prompers, Jeanine J.
    Bakermans, Adrianus J.
    van Nierop, Bastiaan J.
    Abdurrachim, Desiree
    Nicolay, Klaas
    FASEB JOURNAL, 2012, 26
  • [6] Pattern recognition of 31P MRS tumour spectra obtained in vivo
    Howells, S.L.
    Maxwell, R.J.
    Howe, F.A.
    Peet, A.C.
    Stubbs, M.
    Rodrigues, L.M.
    Robinson, S.P.
    Baluch, S.
    Griffiths, J.R.
    NMR in Biomedicine, 1993, 6 (04)
  • [7] Phosphatidylcholine contributes to in vivo 31P MRS signal from the human liver
    Marek Chmelík
    Ladislav Valkovič
    Peter Wolf
    Wolfgang Bogner
    Martin Gajdošík
    Emina Halilbasic
    Stephan Gruber
    Michael Trauner
    Michael Krebs
    Siegfried Trattnig
    Martin Krššák
    European Radiology, 2015, 25 : 2059 - 2066
  • [8] In vivo assessment of mitochondrial functionality in human gastrocnemius muscle by 31P MRS
    Iotti, S.
    Lodi, R.
    Frassineti, C.
    Zaniol, P.
    Barbiroli, B.
    NMR in Biomedicine, 1993, 6 (04)
  • [9] Quantitative proton-decoupled 31P MRS of the schizophrenic brain in vivo
    Blüml, S
    Tan, J
    Harris, K
    Adatia, N
    Karme, A
    Sproull, T
    Ross, B
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1999, 23 (02) : 272 - 275
  • [10] Phosphatidylcholine contributes to in vivo 31P MRS signal from the human liver
    Chmelik, Marek
    Valkovic, Ladislav
    Wolf, Peter
    Bogner, Wolfgang
    Gajdosik, Martin
    Halilbasic, Emina
    Gruber, Stephan
    Trauner, Michael
    Krebs, Michael
    Trattnig, Siegfried
    Krssak, Martin
    EUROPEAN RADIOLOGY, 2015, 25 (07) : 2059 - 2066