Transcatheter closure of multi-hole perimembranous VSD with aneurysm: 3-year follow-up study

被引:21
作者
Wu, Hong [1 ]
Qin, Yongwen [1 ]
Zhao, Xianxian [1 ]
Hu, Jianqiang [1 ]
Zheng, Xing [1 ]
Wang, Ersong [1 ]
Li, Weiping [1 ]
Wang, Yanyan [1 ]
Liu, Bo [1 ]
Liu, Jing [1 ]
Wang, Shengqiang [1 ]
机构
[1] Second Mil Med Univ, Dept Cardiol, Changhai Hosp, Shanghai 200433, Peoples R China
关键词
Ventricular septal defect; Aneurysm; Transcatheter; Occluder; VENTRICULAR SEPTAL-DEFECTS; OCCLUDER; EXPERIENCE; REGISTRY; DEVICE;
D O I
10.1007/s00392-009-0044-y
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The majority of ventricular septal defects (VSDs) are perimembranous, accounting for 75-80% of all VSDs. The objective of this study was to investigate occluder selection and transcatheter closure technique for multi-hole perimembranous VSD with aneurysm, and to evaluate clinical efficacy and safety. Patients with multi-hole VSDs and aneurysm (n = 64) were selected for the procedure using transthoracic echocardiography. Double-disc symmetrical, small-waist double-disc asymmetrical and zero eccentricity occluders were selected based on left ventricular angiography. The closure was successful in 63 of 64 patients (98%). The double-disc symmetrical occluder was used in 16 cases, the small-waist double-disc asymmetrical occluder in 42 cases, and the zero eccentricity occluder in 8 cases (2 occluder types were used in 2 cases). Fifteen minutes after the procedure, 52 cases had no residual shunt and 12 had a trace amount of residual shunt. The residual shunt disappeared in five cases 5-7 days post procedure, with a trace amount of shunt remaining in seven cases. Transient conduction abnormalities related to the procedure occurred in six patients; however, none required permanent pacemaker implantation. At the 1-month, 6-month, 1-year, 2-year, and 3-year follow-up visits, echocardiography indicated that the position of the occluders was fixed, and there were no complications including residual shunt, newly developed atrioventricular block, thromboembolism, or bacterial endocarditis. The study results indicate that left ventricular angiography is useful in selecting the most appropriate device for transcatheter closure of multi-hole perimembranous VSD with aneurysm. The transcatheter closure procedure is safe and effective with little residual shunt and no major complications for up to 3 years of follow-up.
引用
收藏
页码:563 / 569
页数:7
相关论文
共 17 条
[1]   Is complete heart block after surgical closure of ventricular septum defects still an issue? [J].
Andersen, Henrik O. ;
de Leval, Marc R. ;
Tsang, Victor T. ;
Elliott, Martin J. ;
Anderson, Robert H. ;
Cook, Andrew C. .
ANNALS OF THORACIC SURGERY, 2006, 82 (03) :948-957
[2]  
Anil S R, 2005, Indian Heart J, V57, P698
[3]   Initial human experience with the Amplatzer perimembranous ventricular septal occluder device [J].
Bass, JL ;
Kalra, GS ;
Arora, R ;
Masura, J ;
Gavora, P ;
Thanopoulos, BD ;
Torres, W ;
Sievert, H ;
Carminati, M ;
Fischer, G ;
Ewert, P .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2003, 58 (02) :238-245
[4]   Transcatheter closure of congenital ventricular septal defects: results of the European Registry [J].
Carminati, Mario ;
Butera, Gianfranco ;
Chessa, Massimo ;
De Giovanni, Joseph ;
Fisher, Gunter ;
Gewillig, Marc ;
Peuster, Mathias ;
Piechaud, Jean Francois ;
Santoro, Giuseppe ;
Sievert, Horst ;
Spadoni, Isabella ;
Walsh, Kevin .
EUROPEAN HEART JOURNAL, 2007, 28 (19) :2361-2368
[5]  
Gu XP, 2000, CATHETER CARDIO INTE, V50, P502, DOI 10.1002/1522-726X(200008)50:4<502::AID-CCD29>3.0.CO
[6]  
2-8
[7]   Catheter closure of perimembranous ventricular septal defects using the new amplatzer membranous VSD occluder: Initial clinical experience [J].
Hijazi, ZM ;
Hakim, F ;
Abu Haweleh, A ;
Madani, A ;
Tarawna, W ;
Hiari, A ;
Cao, OL .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2002, 56 (04) :508-515
[8]  
Hirsch Rafael, 2007, Acute Card Care, V9, P54, DOI 10.1080/17482940600996894
[9]  
Ho Siew Yen, 2004, J Interv Cardiol, V17, P99, DOI 10.1111/j.1540-8183.2004.09873.x
[10]   Transcatheter closure of perimembranous ventricular septal defects using the amplatzer membranous VSD occluder: Immediate and midterm results of an international registry [J].
Holzer, Ralf ;
de Giovanni, Jo ;
Walsh, Kevin P. ;
Tometzki, Andrew ;
Goh, T. H. ;
Hakim, Fakhri ;
Zabal, Carlos ;
de Lezo, Jose Suarez ;
Cao, Qi-Ling ;
Hijazi, Ziyad M. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2006, 68 (04) :620-628