Analysis of Uncertainties in Clinical High-Energy Photon Beam Calibrations Using Absorbed Dose Standards

被引:2
作者
Elbashir, Fawzia E. M. [1 ]
Ksouri, Wassim [2 ]
Habbani, Farouk [3 ]
El-Khayatt, Ahmed M. [4 ]
Eisa, Mohamed Hassan [4 ]
Suliman, Ibrahim I. [4 ,5 ]
机构
[1] Univ Gezira, Natl Canc Inst, Dept Med Phys, POB 20, Wad Madani, Sudan
[2] Ctr Radiotherapie Hartmann 4, Dept Med Phys, Rue Kleber,CS90004, F-92309 Levallois Perret, France
[3] Univ Khartoum, Fac Sci, Dept Phys, POB 321, Khartoum, Sudan
[4] Imam Mohammad Ibn Saud Islamic Univ IMSIU, Coll Sci, Dept Phys, Riyadh 11642, Saudi Arabia
[5] Sudan Atom Energy Commiss, Radiat & Nucl Safety Inst, POB 3001, Khartoum, Sudan
来源
APPLIED SCIENCES-BASEL | 2022年 / 12卷 / 08期
关键词
radiotherapy; radiation dosimetry; ionization chamber; Linac; absorbed dose to water; dosimetry protocols; DOSIMETRY; WATER; CODE;
D O I
10.3390/app12083857
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
We compared the results of absorbed dose measurements made using the TRS-398, TG-51, and DIN protocols and their associated uncertainties to reduce discrepancies in measurement results made using the three protocols. This experiment was carried out on two Varian Medical linear accelerators with 4, 6, 10, and 20 MV photon energies using FC65-G and CC15 (cylindrical) and NACP-02-type (plane-parallel) ion chambers in water phantoms. The radiation beam quality index (Q) was determined from the measurement of percentage depth dose. It was used to determine the photon beam quality factor required with the ionization chamber calibration factor to convert the ion chamber reading into the absorbed dose to water. For the same beam quality, the TRS-398/TG-51 varied from 0.01% to 1.8%, whereas the ratio for TRS-398/DIN 6800-2 varied from 0.1% to 0.88%. The chamber-to-chamber variation was 0.09% in TRS-398/TG-51, 0.03% in TRS-398/DIN, and 0.02% in TG-51/DIN 6800-2. The expanded uncertainties (k = 1) were 1.24 and 1.25 when using TRS-398 and DIN 6800-2, respectively. Using the aforementioned three protocols, the results showed little chamber-to-chamber variation and uncertainty in absorbed dose measurements. The estimated uncertainties when using cylindrical ion chambers were slightly lower than those measured using plane-parallel chambers. The results are important in facilitating comparisons of absorbed dose measurements when using the three protocols.
引用
收藏
页数:10
相关论文
共 20 条
  • [11] Institute of Physics and Engineering in Medicine (IPEM), 1999, NO81 IPEM
  • [12] International Atomic Energy Agency, 2005, TECDOC1455 IAEA
  • [13] Technical Note: Influence of entrance window deformation on reference dosimetry measurement in various beam modalities
    Kinoshita, Naoki
    Kohno, Ryosuke
    Oguchi, Hiroshi
    [J]. MEDICAL PHYSICS, 2019, 46 (02) : 1037 - 1043
  • [14] Uncertainty in positioning ion chamber at reference depth for various water phantoms
    Kinoshita, Naoki
    Oguchi, Hiroshi
    Adachi, Toshiki
    Shioura, Hiroki
    Kimura, Hirohiko
    [J]. REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2018, 23 (03) : 199 - 206
  • [15] CODE OF PRACTICE FOR HIGH-ENERGY PHOTON THERAPY DOSIMETRY BASED ON THE NPL ABSORBED DOSE CALIBRATION SERVICE
    LILLICRAP, SC
    OWEN, B
    WILLIAMS, JR
    WILLIAMS, PC
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (10) : 1355 - 1360
  • [16] Mayles P, 2007, HDB RADIOTHERAPY PHY, DOI DOI 10.1201/9781420012026
  • [17] Rogers D.W, 2001, ICRU REP, V47, P20, DOI [10.1088/0031-9155/47/20/701, DOI 10.1088/0031-9155/47/20/701]
  • [18] Reference dose determination in 60Co and high-energy radiotherapy photon beams by using Farmer-type cylindrical ionization chambers - an experimental investigation
    Swanpalmer, John
    [J]. BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2020, 6 (04)
  • [19] The Netherlands Commission on Radiation Dosimetry (NCS), 2008, 18 NCS
  • [20] Zakaria A, 2011, Biomed Imaging Interv J, V7, pe15, DOI 10.2349/biij.7.2.e15