Stability and intra-tester reliability of an in vivo measurement of thoracic axial rotation using an innovative methodology

被引:23
作者
Heneghan, Nicola R. [1 ]
Hall, Alison
Hollands, Mark [1 ]
Balanos, George M. [1 ]
机构
[1] Univ Birmingham, Sch Sport & Exercise Sci, Birmingham B15 2TT, W Midlands, England
关键词
Thoracic spine; Axial rotation; Reliability; Motion analysis; SPINE;
D O I
10.1016/j.math.2008.10.004
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
The aim of this study was to evaluate the stability and intra-tester reliability of an innovative approach to measure active thoracic spine axial rotation. Ultrasound imaging of a thoracic vertebra in conjunction with Polhemus motion analysis of the transducer was used to measure axial thoracic spine rotation in a functional position. The range of motion in a convenience sample of asymptomatic subjects (n = 24) was calculated across ten repetitions of a single trial to evaluate stability. The protocol was repeated the same day and 7-10 days later to provide data for within and between day intra-tester reliability. Mean total range of axial rotation was 85.15 degrees across a single trial with SD = 14.8. CV = 17.4, SEM = 3.04. SEM ranged 0.63-3.37 for individual subjects and 2.60-3.64 across repetitions. Stability of performance occurred at repetitions 2-4. Intra-tester reliability (ICC(2,1)) was excellent within day (0.89-0.98) and good/excellent between days (0.72 0.94). Bland-Altman plots however suggest that agreement may range from 0 to 10% for within day measures and from 0 to 15% for between day measures. Whether this combined approach has sufficient precision and accuracy as a clinical research toot has yet to be fully evaluated. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:452 / 455
页数:4
相关论文
共 12 条
  • [1] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [2] Burwell RG, 1999, RES SPINAL DEFORMITI, V2
  • [3] EDMONSTON S, 2006, J MANIP PHYSIOL THER, V30, P193
  • [4] Kirby A, 1999, RES SPINAL DEFORMITI, V59
  • [5] Neck mobility measurement by means of the 'Flock of Birds' electromagnetic tracking system
    Koerhuis, CL
    Winters, JC
    van der Helm, FCT
    Hof, AL
    [J]. CLINICAL BIOMECHANICS, 2003, 18 (01) : 14 - 18
  • [6] Shrout P E, 1998, Stat Methods Med Res, V7, P301, DOI 10.1191/096228098672090967
  • [7] Sim J., 2000, Research in Health Care
  • [8] ULTRASOUND MEASUREMENT OF VERTEBRAL ROTATION IN IDIOPATHIC SCOLIOSIS
    SUZUKI, S
    YAMAMURO, T
    SHIKATA, J
    SHIMIZU, K
    IIDA, H
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1989, 71 (02): : 252 - 255
  • [9] The effect of shoulder movements on thoracic spine 3D motion
    Theodoridis, D
    Ruston, S
    [J]. CLINICAL BIOMECHANICS, 2002, 17 (05) : 418 - 421
  • [10] Walter SD, 1998, STAT MED, V17, P101, DOI 10.1002/(SICI)1097-0258(19980115)17:1<101::AID-SIM727>3.0.CO