Reduced iodine load with CT coronary angiography using dual-energy imaging: A prospective randomized trial compared with standard coronary CT angiography

被引:61
作者
Raju, Rekha [1 ,2 ]
Thompson, Angus G. [1 ,2 ]
Lee, Kristy [1 ,2 ]
Precious, Bruce [1 ,2 ]
Yang, Tae-Hyun [1 ,2 ]
Berger, Adam [1 ,2 ]
Taylor, Carolyn [1 ,2 ]
Heilbron, Brett [1 ,2 ]
Nguyen, Giang [1 ,2 ]
Earls, James [3 ]
Min, James [4 ]
Carrascosa, Patricia [5 ]
Murphy, Darra [1 ,2 ]
Hague, Cameron [1 ,2 ]
Leipsic, Jonathon A. [1 ,2 ]
机构
[1] St Pauls Hosp, Dept Radiol, Vancouver, BC V6Z 1Y6, Canada
[2] St Pauls Hosp, Div Cardiol, Vancouver, BC V6Z 1Y6, Canada
[3] Fairfax Radiol, Fairfax, VA USA
[4] New York Presbyterian, Weil Cornell Med Coll, New York, NY USA
[5] Univ Buenos Aires, Sch Med, Dept Radiol, Buenos Aires, DF, Argentina
基金
美国国家卫生研究院;
关键词
Coronary CT angiography; Dual energy CT; Reduced iodinated contrast; Image quality; Diagnostic Efficacy; COMPUTED TOMOGRAPHIC ANGIOGRAPHY; ARTERY STENOSIS; ACCURACY;
D O I
10.1016/j.jcct.2014.06.003
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: There is concern regarding the administration of iodinated contrast to patients with impaired renal function because of the increased risk of contrast-induced nephropathy. Objective: Evaluate image quality and feasibility of a protocol with a reduced volume of iodinated contrast and utilization of dual-energy coronary CT angiography (DECT) vs a standard iodinated contrast volume coronary CT angiography protocol (SCCTA). Methods: A total of 102 consecutive patients were randomized to SCCTA (n = 53) or DECT with rapid kVp switching (n = 49). Eighty milliliters and 35 mL of iodinated contrast were administered in the SCCTA and DECT cohorts, respectively. Two readers measured signal and noise in the coronary arteries; signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. A 5-point signal/noise Likert scale was used to evaluate image quality; scores of <3 were nondiagnostic. Agreement was assessed through kappa analyses. Results: Demographics and radiation dose were not significantly different; there was no difference in CNR between both cohorts (P = .95). A significant difference in SNR between the groups (P = .02) lost significance (P = .13) when adjusted for body mass index. The median Likert score was inferior for DECT for reader 1 (3.6 +/- 0.6 vs 4.3 +/- 0.6; P < .001) but not reader 2 (4.1 +/- 0.6 vs 4.3 +/- 0.5; P = .06). Agreement in diagnostic interpretability in the DECT and SCCTA groups was 91% (95% confidence interval, 86%-100%) and 96% (95% confidence interval, 90%-100%), respectively. Conclusion: DECT resulted in inferior image quality scores but demonstrated comparable SNR, CNR, and rate of diagnostic interpretability without a radiation dose penalty while allowing for >50% reduction in contrast volume compared with SCCTA. (C) 2014 Society of Cardiovascular Computed Tomography. All rights reserved.
引用
收藏
页码:282 / 288
页数:7
相关论文
共 13 条
[1]   Impact of a Reduced Tube Voltage on CT Angiography and Radiation Dose Results of the PROTECTION I Study [J].
Bischoff, Bernhard ;
Hein, Franziska ;
Meyer, Tanja ;
Hadamitzky, Martin ;
Martinoff, Stefan ;
Schoemig, Albert ;
Hausleiter, Joerg .
JACC-CARDIOVASCULAR IMAGING, 2009, 2 (08) :940-946
[2]  
Bongartz G, 2004, EUROPEAN GUIDELINES
[3]   Diagnostic Performance of 64-Multidetector Row Coronary Computed Tomographic Angiography for Evaluation of Coronary Artery Stenosis in Individuals Without Known Coronary Artery Disease [J].
Budoff, Matthew J. ;
Dowe, David ;
Jollis, James G. ;
Gitter, Michael ;
Sutherland, John ;
Halamert, Edward ;
Scherer, Markus ;
Bellinger, Raye ;
Martin, Arthur ;
Benton, Robert ;
Delago, Augustin ;
Min, James K. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 52 (21) :1724-1732
[4]   Dual-Energy Multidetector CT: How Does It Work, What Can It Tell Us, and When Can We Use It in Abdominopelvic Imaging? [J].
Coursey, Courtney A. ;
Nelson, Rendon C. ;
Boll, Daniel T. ;
Paulson, Erik K. ;
Ho, Lisa M. ;
Neville, Amy M. ;
Marin, Daniele ;
Gupta, Rajan T. ;
Schindera, Sebastian T. .
RADIOGRAPHICS, 2010, 30 (04) :1037-1055
[5]   1977 RIETZ LECTURE - BOOTSTRAP METHODS - ANOTHER LOOK AT THE JACKKNIFE [J].
EFRON, B .
ANNALS OF STATISTICS, 1979, 7 (01) :1-26
[6]   Dual-Energy CT: Clinical Applications in Various Pulmonary Diseases [J].
Kang, Mi-Jin ;
Park, Chang Min ;
Lee, Chang-Hyun ;
Goo, Jin Mo ;
Lee, Hyun Ju .
RADIOGRAPHICS, 2010, 30 (03) :685-698
[7]   Effect of a Standardized Radiation Dose Reduction Protocol on Diagnostic Accuracy of Coronary Computed Tomographic Angiography [J].
LaBounty, Troy M. ;
Leipsic, Jonathon ;
Mancini, G. B. John ;
Heilbron, Brett ;
Patel, Smita ;
Kazerooni, Ella A. ;
Sundaram, Baskaran ;
Lin, Fay Y. ;
Dunning, Allison ;
Saltzman, Adam J. ;
Weisz, Giora ;
Weinsaft, Jonathan W. ;
Choi, Jin-Ho ;
Koduru, Sunaina ;
Min, James K. .
AMERICAN JOURNAL OF CARDIOLOGY, 2010, 106 (02) :287-292
[8]   Estimated Radiation Dose Reduction Using Adaptive Statistical Iterative Reconstruction in Coronary CT Angiography: The ERASIR Study [J].
Leipsic, Jonathon ;
LaBounty, Troy M. ;
Heilbron, Brett ;
Min, James K. ;
Mancini, G. B. John ;
Lin, Fay Y. ;
Taylor, Carolyn ;
Dunning, Allison ;
Earls, James P. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (03) :655-660
[9]   Relationship of coronary artery plaque composition to coronary artery stenosis severity: Results from the prospective multicenter ACCURACY trial [J].
Min, James K. ;
Edwardes, Michael ;
Lin, Fay Y. ;
Labounty, Troy ;
Weinsaft, Jonathan W. ;
Choi, Jin-Ho ;
Delago, Augustin ;
Shaw, Leslee J. ;
Berman, Daniel S. ;
Budoff, Matthew J. .
ATHEROSCLEROSIS, 2011, 219 (02) :573-578
[10]   Contrast medium dose-to-GFR ratio:: A measure of systemic exposure to predict contrast-induced nephropathy after percutaneous coronary intervention [J].
Nyman, U. ;
Bjork, J. ;
Aspelin, P. ;
Marenzi, G. .
ACTA RADIOLOGICA, 2008, 49 (06) :658-667