Laser-Assisted Indocyanine Green Dye Angiography Accurately Predicts the Split-Thickness Graft Timing of Integra Artificial Dermis

被引:17
作者
Fourman, Mitchell S. [1 ]
Phillips, Brett T. [1 ]
Fritz, Jason R. [2 ]
Conkling, Nicole [3 ]
McClain, Steve A. [1 ]
Simon, Marcia [1 ]
Dagum, Alexander B. [1 ]
机构
[1] SUNY Stony Brook, Med Ctr, Stony Brook, NY 11794 USA
[2] Feinstein Inst Med Res, Manhasset, NY USA
[3] Univ Calif San Francisco, San Francisco, CA 94143 USA
关键词
Integra; perfusion; indocyanine green; laser Doppler; skin graft; BLOOD-FLOW; SKIN; TRIAL; BURNS;
D O I
10.1097/SAP.0000000000000206
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: The use of an artificial dermal substitute such as Integra-a bilaminate combination of thin silicone and cross-linked bovine tendon collagen and chondroitin-6-sulfate-has become a popular method to address large surface area wounds or smaller, complex wounds devoid of a vascular bed. The incorporation of Integra depends on a vascular wound bed or periphery and can take 4 weeks or longer to occur. If the Integra has not fully incorporated at the time of placement of the split-thickness graft, complete graft loss may result. The availability of a minimally invasive method to assess the incorporation of Integra would be of great value. Methods: Two 5 x 10-cm paraspinal full-thickness wounds were created on 3 female swine. Wounds were randomly assigned full-thickness skin graft or Integra (Plainsboro, NJ) treatment. Both types of grafts were placed after the application of fibrin glue (Tisseel, Deerfield, Ill) to the wound bed. Laser Doppler imaging (LDI) (Moor), indocyanine green dye (ICG) angiography (LifeCell SPY), and clinical scoring were performed weekly for a period of 8 weeks after grafting. At 4 weeks, the silicone layer of the Integra was removed, and a culture of autologous keratinocytes was applied. A 4-mm punch biopsy sample of each graft was taken 1, 2, 4, 6, 7, and 8 weeks postoperatively for histologic analysis. Results: Both ICG angiography and LDI perfusion measurements noted an increase in perfusion at the Integra graft site that peaked 3 weeks after grafting, corresponding with the start of neovascularization and the optimal time for the application of a split-thickness skin graft. Indocyanine green dye angiography measurements exhibit greater reproducibility between animals at late time points as compared with LDI. This decrease in LDI precision is directly related to increases in scar tissue thickness of greater than 5 mm as determined via histologic analysis and corresponds with the accepted maximum penetration depth of the LDI laser. Conclusions: Indocyanine green dye angiography may provide valuable information as to graft integrity and split-thickness skin graft timing at late time points. Range of LDI seems to be insufficient for split-thickness graft timing or late time point accuracy. Future exploration of ICG angiography potential will involve tracking Integra graft delay in porcine models.
引用
收藏
页码:150 / 155
页数:6
相关论文
共 26 条
[1]  
Brigham Peter A., 1996, Journal of Burn Care and Rehabilitation, V17, P95, DOI 10.1097/00004630-199603000-00003
[2]   SUCCESSFUL USE OF A PHYSIOLOGICALLY ACCEPTABLE ARTIFICIAL SKIN IN THE TREATMENT OF EXTENSIVE BURN INJURY [J].
BURKE, JF ;
YANNAS, IV ;
QUINBY, WC ;
BONDOC, CC ;
JUNG, WK .
ANNALS OF SURGERY, 1981, 194 (04) :413-428
[3]  
Campitiello E, 2005, Acta Biomed, V76 Suppl 1, P69
[4]   Histologic localization of indocyanine green dye in aging primate and human ocular tissues with clinical angiographic correlation [J].
Chang, AA ;
Morse, LS ;
Handa, JT ;
Morales, RB ;
Tucker, R ;
Hjelmeland, L ;
Yannuzzi, LA .
OPHTHALMOLOGY, 1998, 105 (06) :1060-1068
[5]  
Dantzer E, 2001, Ann Chir Plast Esthet, V46, P173, DOI 10.1016/S0294-1260(01)00019-X
[6]  
Fourman MP, 2012, PLAST RECONSTR SURG, V130, P101
[7]   Comparison of Native Porcine Skin and a Dermal Substitute Using Tensiometry and Digital Image Speckle Correlation [J].
Fritz, Jason R. ;
Phillips, Brett T. ;
Conkling, Nicole ;
Fourman, Mitchell ;
Melendez, Mark M. ;
Bhatnagar, Divya ;
Simon, Marcia ;
Rafailovich, Miriam ;
Dagum, Alexander B. .
ANNALS OF PLASTIC SURGERY, 2012, 69 (04) :462-467
[8]  
Greenwood John, 2009, Eplasty, V9, pe33
[9]   Photoacoustic monitoring of granulation tissue grown in a grafted artificial dermis on rat skin [J].
Hatanaka, Kousuke ;
Sato, Shunichi ;
Saitoh, Daizoh ;
Ashida, Hiroshi ;
Sakamoto, Toshihisa .
WOUND REPAIR AND REGENERATION, 2010, 18 (03) :284-290
[10]   ARTIFICIAL DERMIS FOR MAJOR BURNS - A MULTI-CENTER RANDOMIZED CLINICAL-TRIAL [J].
HEIMBACH, D ;
LUTERMAN, A ;
BURKE, J ;
CRAM, A ;
HERNDON, D ;
HUNT, J ;
JORDAN, M ;
MCMANUS, W ;
SOLEM, L ;
WARDEN, G ;
ZAWACKI, B .
ANNALS OF SURGERY, 1988, 208 (03) :313-320