Reproducibility of performance in three types of training test in swimming

被引:20
作者
Alberty, M. [1 ]
Sidney, M. [1 ]
Huot-Marchand, F. [1 ]
Dekerle, J. [1 ]
Bosquet, L. [1 ]
Gorce, P. [1 ]
Lensel, G. [1 ]
机构
[1] Univ Lille 2, Fac Sci Sport, Lab Etud Motricite Humaine, F-59790 Ronchin, France
关键词
reliability; constant distance test; constant time test; constant velocity test;
D O I
10.1055/s-2005-865814
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
A variety of testing procedures are used to assess the effects of particular treatments on the training status of athletes. The present study aims to investigate the reproducibility of selected tests in swimming. Sixteen trained swimmers performed three kinds of test: 1) Constant Distance Test (CDT), 2) Constant Time Test (CTT), and 3) Constant Velocity Test (CVT). The analysis of the reproducibility was based on a test-retest procedure. The test-retest performances were highly correlated for the three kinds of test (r = 0.98, 0.98, and 0.93 for CDT, CTT and CVT, respectively). The mean Coefficient of Variation (CV) was computed between test-retest for each subject and each procedure. A repeated measures one-way ANOVA showed that CVT was significantly less reliable (CV = 6.46 +/- 6.24 %) than CDT and CTT (CV = 0.56 +/- 0.60% and 0.63 +/- 0.54% respectively) (p < 0.001). Psychological factors and a lack of familiarity with CVT (not extensively used during training session) could explain its greater variability. Thus, CDT and CTT seem to be the most reliable tests to detect the smallest meaningful change in the training status of swimmers. Post-hoc power calculations of the experimental design showed the sample size would have to increase to 80,113, and 228 subjects for CWT, CDT and CPT respectively, to reach a power of 80%. The minimal detectable differences have to be calculated to ensure a real effect of a particular treatment on a group of swimmers, according to the kind of test used.
引用
收藏
页码:623 / 628
页数:6
相关论文
共 34 条
[1]  
BAUSELL RB, 2002, POWER ANAL EXPT RES, P376
[2]   REPRODUCIBILITY OF RUNNING TIME TO EXHAUSTION AT VO2MAX IN SUBELITE RUNNERS [J].
BILLAT, V ;
RENOUX, JC ;
PINOTEAU, J ;
PETIT, B ;
KORALSZTEIN, JP .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1994, 26 (02) :254-257
[3]   Reliability of a 1-h endurance performance test in trained female cyclists [J].
Bishop, D .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1997, 29 (04) :554-559
[4]  
CHOLLET D, 1996, SWIMMING SCI, V7, P172
[5]   Ventilatory thresholds in arm and leg exercises with spontaneously chosen crank and pedal rates [J].
Dekerle, J ;
Dupont, L ;
Caby, I ;
Marais, G ;
Vanvelcenaher, J ;
Lavoie, JM ;
Pelayo, P .
PERCEPTUAL AND MOTOR SKILLS, 2002, 95 (03) :1035-1046
[6]   Validity and reliability of critical speed, critical stroke rate, and anaerobic capacity in relation to front crawl swimming performances [J].
Dekerle, J ;
Sidney, M ;
Hespel, JM ;
Pelayo, P .
INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2002, 23 (02) :93-98
[7]  
Fernandes RJ, 2003, INT J SPORTS MED, V24, P576
[8]   DAY TO DAY VARIATION IN TIME TRIAL CYCLING PERFORMANCE [J].
HICKEY, MS ;
COSTILL, DL ;
MCCONELL, GK ;
WIDRICK, JJ ;
TANAKA, H .
INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 1992, 13 (06) :467-470
[9]   Measures of reliability in sports medicine and science [J].
Hopkins, WG .
SPORTS MEDICINE, 2000, 30 (01) :1-15
[10]   Variability of competitive performance of distance runners [J].
Hopkins, WG ;
Hewson, DJ .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2001, 33 (09) :1588-1592