A new metal artifact reduction algorithm based on a deteriorated CT image

被引:7
作者
Kano, Toru [1 ]
Koseki, Michihiko [2 ]
机构
[1] Tokyo Univ Technol, Sch Media Sci, 1404-1 Katakura, Hachioji, Tokyo 1920982, Japan
[2] Shinshu Univ, Fac Text Sci & Technol, Ueda, Nagano, Japan
关键词
Computer tomography (CT); metal artifact; image reconstruction; image processing; iterative reconstruction; COMPUTED-TOMOGRAPHY;
D O I
10.3233/XST-160600
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
BACKGROUND: Computed tomography (CT) is an established imaging technology primarily used as a non-invasive diagnostic tool that reconstructs axial images. However, significant problems with metal artifacts remain. A metal artifact is a strong radial noise in an image, which makes it difficult to diagnose patients and inspect products containing metal implants. Historically, studies related to metal artifact reduction used projection data, though the data is not typically saved after processing. OBJECTIVE: This study proposes a new metal artifact reduction algorithm that does not require projection data, for new applications and for accurate diagnostic techniques. METHODS: The algorithm utilizes reconstructed images and is based on iterative reconstruction. By reproducing an accurate forward projection on simulation and combining it with an iterative calculation, discrepancies causing metal artifacts are eliminated. RESULTS: Validation was completed with numerical phantom models. Our results indicate that the proposed algorithm effectively reduces metal artifacts, even if numerous complex-shaped metal pieces were embedded in the cross-section. CONCLUSIONS: We developed a novel reconstruction algorithm for metal artifact reduction in CT imaging that only requires reconstructed images and projection conditions. Any historical CT data containing metal artifacts could be improved with this method.
引用
收藏
页码:901 / 912
页数:12
相关论文
共 18 条
[11]   EVALUATION OF A PROTOTYPE DUAL-ENERGY COMPUTED TOMOGRAPHIC APPARATUS .1. PHANTOM STUDIES [J].
KALENDER, WA ;
PERMAN, WH ;
VETTER, JR ;
KLOTZ, E .
MEDICAL PHYSICS, 1986, 13 (03) :334-339
[12]   Normalized metal artifact reduction (NMAR) in computed tomography [J].
Meyer, Esther ;
Raupach, Rainer ;
Lell, Michael ;
Schmidt, Bernhard ;
Kachelriess, Marc .
MEDICAL PHYSICS, 2010, 37 (10) :5482-5493
[13]   Empirical dual energy calibration (EDEC) for cone-beam computed tomography [J].
Stenner, Philip ;
Berkus, Timo ;
Kachelriess, Marc .
MEDICAL PHYSICS, 2007, 34 (09) :3630-3641
[14]   Fast iterative algorithm for metal artifact reduction in X-ray CT [J].
Wang, G ;
Frei, T ;
Vannier, MW .
ACADEMIC RADIOLOGY, 2000, 7 (08) :607-614
[15]   A novel approach for reducing metal artifacts due to metallic dental implants [J].
Yazdi, Mehran ;
Beaulieu, Luc .
2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, :2260-2263
[16]   Dual-Energy CT-Based Monochromatic Imaging [J].
Yu, Lifeng ;
Leng, Shuai ;
McCollough, Cynthia H. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (05) :S9-S15
[17]   Reducing metal artifacts in cone-beam CT images by preprocessing projection data [J].
Zhang, Yongbin ;
Zhang, Lifei ;
Zhu, Ronald ;
Lee, Andrew K. ;
Chambers, Mark ;
Dong, Lei .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 67 (03) :924-932
[18]  
Zhao SY, 2001, J X-RAY SCI TECHNOL, V10, P67