Quantitative analysis of erythromycylamine in human plasma by liquid chromatography-tandem mass spectrometry and its application in a bioequivalence study of dirithromycin enteric-coated tablets with a special focus on the fragmentation pattern and carryover effect

被引:7
作者
Cai, Hua-Lin [1 ]
Wang, Feng [1 ]
Li, Huan-De [1 ]
Peng, Wen-Xing [1 ]
Zhu, Rong-Hua [1 ]
Deng, Yang [1 ]
Jiang, Pei [1 ]
Yan, Miao [1 ]
Hu, Si-Miao [2 ]
Lei, Su-Yun [2 ]
Chen, Chang [2 ]
机构
[1] Cent S Univ, Xiangya Hosp 2, Clin Pharm & Pharmacol Res Inst, Changsha 410011, Hunan, Peoples R China
[2] Changsha Med Coll, Dept Pharm, Changsha 410219, Hunan, Peoples R China
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2014年 / 947卷
关键词
Dirithromycin; Erythromycylamine; LC-MS/MS; Fragmentation pattern; Carryover effect; Bioequivalence; MACROLIDE ANTIBIOTICS; AZITHROMYCIN; CLARITHROMYCIN; ROXITHROMYCIN;
D O I
10.1016/j.jchromb.2013.12.019
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A liquid chromatography-tandem mass spectrometry method was developed and validated for the quantification of erythromycylamine, which is the predominant active metabolite of dirithromycin in human plasma. After solid-phase extraction, the analyte and internal standard (IS) were separated by using an isocratic mobile phase consisting of 20 mM ammonium acetate (pH 3.9, adjusted with formic acid)acetonitrile (75:25, v/v) on a Phenyl-Hexyl column (150 x 2.1 mm, 3 mu m) and then analyzed in positive ion mode under electrospray ionization. Azithromycin was selected as the IS because it has the most similar mass spectrometric and chromatographic behaviors to the analyte. The respective multiple reaction monitoring (MRM) transitions, m/z 368.5 > 83.2 for erythromycylamine and m/z 375.4 > 115.2 for IS were chosen to achieve high sensitivity and selectivity in determination. A more acidic mobile phase (pH 3.9) than those of previous reports and a special needle wash (ethylene glycol-acetonitrile-water, 50:30:20, v/v/v, adjusted to pH 3.9 using formic acid) were used to eliminate the carryover effects of the two macrolides. The method exhibited a linear dynamic range of 0.5-440.0 ng/mL for erythromycylamine in human plasma (r=0.9999). The lower limit of quantification (LLOQ) and limit of detection (LOD) were 0.5 and 0.05 ng/mL, respectively. The mean extraction recoveries were higher than 94.0% for the analyte and IS. The intra- and inter-day precisions ranged from 1.4 to 5.4% and from 1.6 to 4.0%, respectively. The accuracy varied between 91.2 and 101.2%. The established method was successfully applied to analyze the human plasma samples from 24 healthy subjects in a bioequivalence study of two dirithromycin enteric-coated formulations. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:156 / 163
页数:8
相关论文
共 18 条
  • [1] Linear regression for calibration lines revisited: weighting schemes for bioanalytical methods
    Almeida, AM
    Castel-Branco, MM
    Falcao, AC
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 774 (02): : 215 - 222
  • [2] [Anonymous], 2001, Guidance for industry, bioanalytical method validation
  • [3] Bekele L. K., ISRN ANAL CHEM, DOI [10.5402/2012/859473, DOI 10.5402/2012/859473]
  • [4] A comparison of 5-day courses of dirithromycin and azithromycin in the treatment of acute exacerbations of chronic obstructive pulmonary disease
    Castaldo, RS
    Celli, BR
    Gomez, F
    LaVallee, N
    Souhrada, J
    Hanrahan, JP
    [J]. CLINICAL THERAPEUTICS, 2003, 25 (02) : 542 - 557
  • [5] Characterisation of dirithromycin and spiramycin using high performance liquid chromatography and direct infusion mass spectrometry
    de la Huebra, MJG
    Vincent, U
    Bordin, G
    Rodríguez, AR
    [J]. ANALYTICA CHIMICA ACTA, 2004, 503 (02) : 247 - 256
  • [6] LC-MS2 trace analysis of antimicrobials in water, sediment and soil
    Díaz-Cruz, MS
    Barceló, D
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2005, 24 (07) : 645 - 657
  • [7] Hedgepeth W., APPL NOTE
  • [8] Simultaneous determination of five macrolide antibiotics in meat by high-performance liquid chromatography
    Horie, M
    Saito, K
    Ishii, R
    Yoshida, T
    Haramaki, Y
    Nakazawa, H
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1998, 812 (1-2) : 295 - 302
  • [9] Determination of carryover and contamination for mass spectrometry-based chromatographic assays
    Hughes, Nicola C.
    Wong, Ernest Y. K.
    Fan, Juan
    Bajaj, Navgeet
    [J]. AAPS JOURNAL, 2007, 9 (03) : E353 - E360
  • [10] Determination of macrolides in biological matrices by high-performance liquid chromatography with electrochemical detection
    Kees, F
    Spangler, S
    Wellenhofer, M
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1998, 812 (1-2) : 287 - 293