Angle Stable Nails Provide Improved Healing for a Complex Fracture Model in the Femur

被引:5
|
作者
Kubacki, Meghan R. [2 ]
Verioti, Christopher A. [1 ]
Patel, Savan D. [1 ]
Garlock, Adam N. [2 ]
Fernandez, David [1 ]
Atkinson, Patrick J. [1 ,2 ]
机构
[1] McLaren Flint, Flint, MI USA
[2] Kettering Univ, Dept Mech Engn, Flint, MI 48504 USA
关键词
SEGMENTAL BONE DEFECTS; INTERLOCKING NAIL; FEMORAL FRACTURES; CANINE TIBIAE; FIXATION; LOCKING; STABILITY; SIZE; GAP; SYSTEMS;
D O I
10.1007/s11999-013-3288-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Conventional nails are being used for an expanding range of fractures from simple to more complex. Angle stable designs are a relatively new innovation; however, it is unknown if they will improve healing for complex fractures. When comparing traditional and angle stable nails to treat complex open canine femur fractures, the current study addressed the following questions: do the two constructs differ in (1) radiographic evidence of bone union across the cortices; (2) stability as determined by toggle (torsional motion with little accompanying torque) and angular deformation; (3) biomechanical properties, including stiffness in bending, axial compression, and torsional loading, and construct failure properties in torsion; and (4) degree of bone tissue mineralization? Ten hounds with a 1-cm femoral defect and periosteal stripping were treated with a reamed titanium angle stable or nonangle stable nail after the creation of a long soft tissue wound. Before the study, the animals were randomly assigned to receive one of the nails and to be evaluated with biomechanical testing or histology. After euthanasia at 16 weeks, all operative femora were assessed radiographically. Histological or biomechanical evaluation was conducted of the operative bones with nails left in situ compared with the nonoperative contralateral femora. Radiographic and gross inspection demonstrated hypertrophic nonunion in all 10 animals treated with the nonangle stable nail, whereas six of 10 animals treated with the angle stable nail bridged at least one cortex (p = 0.023). The angle stable nail construct demonstrated no toggle in nine of 10 animals, whereas all control femora exhibited toggle. The angle stable nail demonstrated less angular deformation and toggle (p a parts per thousand currency sign 0.005) and increased compressive stiffness (p = 0.001) compared with the conventional nonangle stable nail. Histology demonstrated more nonmineralized tissue in the limbs treated with the conventional nail (p = 0.005). Angle stable nails that eliminate toggle lead to enhanced yet incomplete fracture healing in a complex canine fracture model. Care should be taken in tailoring the nail design features to the characteristics of the fracture and the patient.
引用
收藏
页码:1300 / 1309
页数:10
相关论文
共 16 条
  • [1] Local pamidronate influences fracture healing in a rodent femur fracture model: an experimental study
    Menzdorf, Leif
    Weuster, Matthias
    Klueter, Tim
    Brueggemann, Stefan
    Behrendt, Peter
    Fitchen-Oestern, Stefanie
    Varoga, Deike
    Seekamp, Andreas
    Purcz, Nicolai
    Glueer, Claus C.
    Pufe, Thomas
    Lippross, Sebastian
    BMC MUSCULOSKELETAL DISORDERS, 2016, 17
  • [2] Low cost polymer intramedullary nails for fracture fixation: a biomechanical study in a porcine femur model
    Lewis, D.
    Lutton, C.
    Wilson, L. J.
    Crawford, R. W.
    Goss, B.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2009, 129 (06) : 817 - 822
  • [3] A Biomechanical Comparison of Locked and Unlocked Long Cephalomedullary Nails in a Stable Intertrochanteric Fracture Model
    Kane, Patrick
    Vopat, Bryan
    Paller, David
    Koruprolu, Sarath
    Daniels, Alan H.
    Born, Christopher
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2014, 28 (12) : 715 - 720
  • [4] In Vivo Biomechanical Evaluation of a Novel Angle-Stable Interlocking Nail Design in a Canine Tibial Fracture Model
    Dejardin, Loic M.
    Cabassu, Julien B.
    Guillou, Reunan P.
    Villwock, Mark
    Guiot, Laurent P.
    Haut, Roger C.
    VETERINARY SURGERY, 2014, 43 (03) : 271 - 281
  • [5] Mechanical evaluation of a novel angle-stable interlocking nail in a gap fracture model
    Deprey, Julie
    Blondel, Margaux
    Saban, Charles
    Massenzio, Michel
    Gauthier, Olivier
    Moissonnier, Pierre
    Viguier, Eric
    Cachon, Thibaut
    VETERINARY SURGERY, 2022, 51 (08) : 1247 - 1256
  • [6] Effect of Pentoxifylline Administration on an Experimental Rat Model of Femur Fracture Healing With Intramedullary Fixation
    Farahani, Mohammad Mahdi Vashghani
    Farahani, Reza Masteri
    Mostafavinia, Ataroalsadat
    Abbasian, Mohammad Reza
    Pouriran, Ramin
    Noruzian, Mohammad
    Ghoreishi, Seyed Kamran
    Aryan, Arefe
    Bayat, Mohammad
    IRANIAN RED CRESCENT MEDICAL JOURNAL, 2015, 17 (12)
  • [7] Improved weight bearing during gait at 6 weeks post-surgery with an angle stable locking system after distal tibial fracture
    Agres, Alison N.
    Alves, Sonia A.
    Hoentzsch, Dankward
    El Attal, Rene
    Pohlemann, Tim
    Schaser, Klaus-Dieter
    Joeris, Alexander
    Hess, Denise
    Duda, Georg N.
    GAIT & POSTURE, 2024, 107 : 169 - 176
  • [8] A modified intramedullary nail interlocking design yields improved stability for fatigue cycling in a canine femur fracture model
    Garlock, Adam N.
    Donovan, Jim
    LeCronier, David J.
    Houghtaling, John
    Burton, Stephen
    Atkinson, Patrick J.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2012, 226 (H6) : 469 - 476
  • [9] Additional Tension Screws Improve Stability in Elastic Stable Intramedullary Nailing: Biomechanical Analysis of a Femur Spiral Fracture Model
    Zachert, Gregor
    Rapp, Marion
    Eggert, Rebecca
    Schulze-Hessing, Maaike
    Gros, Nina
    Stratmann, Christina
    Wendlandt, Robert
    Kaiser, Martin M.
    EUROPEAN JOURNAL OF PEDIATRIC SURGERY, 2015, 25 (04) : 365 - 372
  • [10] Comparison of healing intra-articular fracture of distal femur using a Kirschner wire and autologous fibrin glue in an animal model
    Azarpira, Mohammad R.
    Vazani, Kasra
    Ayatollahi, Maryam
    Azarpira, Negar
    Kaviani, Maryam
    JOURNAL OF PEDIATRIC ORTHOPAEDICS-PART B, 2017, 26 (05): : 454 - 457