Limited-data image registration for radiotherapy positioning and verification

被引:54
作者
Ruchala, KJ
Olivera, GH
Kapatoes, JM
机构
[1] TomoTherapy Inc, Middleton, WI 53562 USA
[2] Univ Wisconsin, Dept Med Phys, Madison, WI 53706 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2002年 / 54卷 / 02期
关键词
image fusion; image registration; adaptive radiotherapy; on-line CT; IMRT;
D O I
10.1016/S0360-3016(02)02895-X
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: One benefit to having on-line CT imaging integrated into a radiotherapy system is that images can be collected with the patient in the treatment position. These images can then be automatically registered to planning images for improved positioning and verification. However, many such on-line imaging systems have a limited field of view (LFOV) that could potentially impair registration. Thus, the viability of automatic registration was investigated in the context of collecting on-line LFOV and also limited-slice CT images for radiotherapy. Methods and Materials: Mutual information and two new voxel-based registration algorithms were tested to align LFOV and limited-slice prostate and breast images given known displacements. Success rates were tallied for different field-of-view sizes, slice distributions, and initial displacements. Results: Most of the automatic registration algorithms tested were useful for solving these LFOV and limited-slice problems. Registration of LFOV images was generally successful, especially for fields of view of at least half the patient's size. For limited-slice images, success was more closely correlated to the slice spacing than to the number of slices used, with sparse slice spacing being preferable. Conclusions: Mutual information and other automatic registration algorithms have been identified as useful methods for registering LFOV and limited-slice radiotherapy images with planning CT images. (C) 2002 Elsevier Science Inc.
引用
收藏
页码:592 / 605
页数:14
相关论文
共 33 条
[1]  
[Anonymous], 1987, PRINCIPLES COMPUTERI
[2]  
[Anonymous], 1992, NUMERICAL RECIPES C
[3]   CONE-BEAM CT FOR RADIOTHERAPY APPLICATIONS [J].
CHO, PS ;
JOHNSON, RH ;
GRIFFIN, TW .
PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (11) :1863-1883
[4]  
FORD E, 2001, MED PHYS, V28, P1232
[5]   Feasibility of megavoltage portal CT using an electronic portal imaging device (EPID) and a multi-level scheme algebraic reconstruction technique (MLS-ART) [J].
Guan, HQ ;
Zhu, YP .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (10) :2925-2937
[6]   Clinical use of electronic portal imaging: Report of AAPM radiation therapy committee Task Group 58 [J].
Herman, MG ;
Balter, JM ;
Jaffray, DA ;
McGee, KP ;
Munro, P ;
Shalev, S ;
Van Herk, M ;
Wong, JW .
MEDICAL PHYSICS, 2001, 28 (05) :712-737
[7]   Tomotherapeutic portal imaging for radiation treatment verification [J].
Hesse, BM ;
Spies, L ;
Groh, BA .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (12) :3607-3616
[8]   Medical image registration [J].
Hill, DLG ;
Batchelor, PG ;
Holden, M ;
Hawkes, DJ .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (03) :R1-R45
[9]  
HUA C, 2001, MED PHYS, V28, P1258
[10]   A radiographic and tomographic imaging system integrated into a medical linear accelerator for localization of bone and soft-tissue targets [J].
Jaffray, DA ;
Drake, DG ;
Moreau, M ;
Martinez, AA ;
Wong, JW .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (03) :773-789