FEA and microstructure characterization of a one-piece Y-TZP abutment

被引:7
作者
da Silva, Lucas Hian [1 ]
Ribeiro, Sebastiao [2 ]
Souto Borges, Alexandre Luis [3 ]
Cesar, Paulo Francisco [1 ]
Tango, Rubens Nisie [3 ]
机构
[1] Univ Sao Paulo, Fac Dent, Dept Biomat & Oral Biol, Sao Paulo, Brazil
[2] Univ Sao Paulo, Lorenas Engn Sch, Dept Mat Engn, Lorena, Sao Paulo, Brazil
[3] Sao Paulo State Univ UNESP, Fac Dent, Dept Ddent Mat & Prosthodont, Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
Y-TZP; Implant abutment; Slip-cast; Ceramics; Dental implant; Prosthodontics; Biomaterials; Esthetic dentistry; Oral rehabilitation; YTTRIA-STABILIZED ZIRCONIA; IN-VITRO; MECHANICAL-PROPERTIES; FRACTURE-RESISTANCE; IMPLANT ABUTMENTS; FLEXURAL STRENGTH; CONNECTIONS; TEMPERATURE; HEX;
D O I
10.1016/j.dental.2014.05.016
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives. The most important drawback of dental implant/abutment assemblies is the need for a fixing screw. This study aimed to develop an esthetic one-piece Y-TZP abutment to suppress the use of the screw. Methods. Material characterization was performed using a bar-shaped specimen obtained by slip-casting to validate the method prior to prototype abutment fabrication by the same process. The mechanical behavior of the prototype abutment was verified and compared with a conventional abutment by finite element analysis (FEA). The abutment was evaluated by micro-CT analysis and its density was measured. Results. FEA showed stress concentration at the first thread pitch during installation and in the cervical region during oblique loading for both abutments. However, stress concentration was observed at the base of the screw head and stem in the conventional abutment. The relative density for the fabricated abutment was 95.68%. Micro-CT analysis revealed the presence of elongated cracks with sharp edges over the surface and porosity in the central region. Significance. In the light of these findings, the behavior of a one-piece abutment is expected to be better than that of the conventional model. New studies should be conducted to clarify the performance and longevity of this one-piece Y-TZP abutment. (C) 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:E283 / E288
页数:6
相关论文
共 28 条
  • [1] Fracture Resistance of Yttria-Stabilized Zirconia Dental Implant Abutments
    Adatia, Nimet D.
    Bayne, Stephen C.
    Cooper, Lyndon F.
    Thompson, Jeffery Y.
    [J]. JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2009, 18 (01): : 17 - 22
  • [2] [Anonymous], 2007, E18762007 ASTM
  • [3] [Anonymous], 2002, E13821997 ASTM
  • [4] Survival rate, fracture strength and failure mode of ceramic implant abutments after chewing simulation
    Butz, F
    Heydecke, G
    Okutan, M
    Strub, JR
    [J]. JOURNAL OF ORAL REHABILITATION, 2005, 32 (11) : 838 - 843
  • [5] Low temperature degradation of a Y-TZP dental ceramic
    Cattani-Lorente, Maria
    Scherrer, Susanne S.
    Ammann, Patrick
    Jobin, Marc
    Wiskott, H. W. Anselm
    [J]. ACTA BIOMATERIALIA, 2011, 7 (02) : 858 - 865
  • [6] Cho Sang-Choon, 2004, Implant Dent, V13, P245, DOI 10.1097/01.id.0000140459.87333.f8
  • [7] Analyzing the Effects of the Platform-Switching Procedure on Stresses in the Bone and Implant-Abutment Complex by 3-Dimensional Fem Analysis
    Cimen, Haydar
    Yengin, Esengun
    [J]. JOURNAL OF ORAL IMPLANTOLOGY, 2012, 38 (01) : 21 - 26
  • [8] Effect of repeated torque/mechanical loading cycles on two different abutment types in implants with internal tapered connections: an in vitro study
    Coppede, Abilio Ricciardi
    Chiarello de Mattos, Maria da Gloria
    Silveira Rodrigues, Renata Cristina
    Ribeiro, Ricardo Faria
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (06) : 624 - 632
  • [9] Coppedê AR, 2009, INT J PROSTHODONT, V22, P283
  • [10] Sintering of zirconia composites obtained by slip casting
    dos Santos, IMG
    Moreira, RCM
    Leite, ER
    Longo, E
    Varela, JA
    [J]. CERAMICS INTERNATIONAL, 2001, 27 (03) : 283 - 289