Methods: Consecutive patients with end-stage heart failure who underwent ICD implantation and LV reconstruction were evaluated. During admission, two-dimensional (2D) echocardiography (LV volumes and LVEF) was performed before surgery and was repeated at 3 months after surgery. Over a median follow-up of 18 months, the incidence of ICD therapy was evaluated. Results: The study population consisted of 37 patients (59 +/- 11 years). At baseline, mean LVEF was 23 +/- 5%. Mean left ventricular end-systolic volume (LVESV) and left ventricular end-diastolic volume (LVEDV) were 175 +/- 73 mL and 225 +/- 88 mL, respectively. At 3-month follow-up, mean LVEF was 41 +/- 9% (P < 0.0001 vs. baseline), and mean LVESV and LVEDV were 108 +/- 65 mL and 176 +/- 73 mL, respectively (P < 0.0001 vs. baseline). During 18-month follow-up, 12 (32%) patients had ventricular arrhythmias, resulting in appropriate ICD therapy. No significant relations existed between baseline LVEF (P = 0.77), LVEF at 3-month follow-up (P = 0.34), change in LVEF from baseline to 3-month follow-up (P = 0.28), and the occurrence of ICD therapy during 18-month follow-up. Conclusion: LVEF before and after surgical LV reconstruction is of limited use as criterium for ICD implantation in patients with end-stage heart failure. (PACE 2009; 32:913-917).