Assay of anti-coagulant drug warfarin sodium in pharmaceutical formulation and human biological fluids by square-wave adsorptive cathodic stripping voltammetry

被引:32
作者
Ghoneim, MM [1 ]
Tawfik, A [1 ]
机构
[1] Tanta Univ, Fac Sci, Dept Chem, Tanta 31527, Egypt
关键词
warfarin sodium; determination; hemofarin tablets; human serum and urine; stripping voltammetry; cyclic voltammetry;
D O I
10.1016/j.aca.2004.01.037
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The cyclic voltammogram of the anti-coagulant drug warfarin sodium at the hanging mercury drop electrode exhibited a well-defined single two-electron irreversible peak over the pH range 4-7, which may be attributed to the reduction of the C=O double bond of the drug molecule. Based on the interfacial adsorptive character of the drug onto the mercury electrode surface, a square-wave cathodic stripping procedure was optimized for its trace determination. The calibration plot was linear over the concentration range of 5 x 10(-9) to 4 x 10(-7) M warfarin sodium in Britton-Robinson (B-R) buffer of pH 5, with limits of detection and quantitation of 6.5 x 10(-10) and 2.1 x 10(-9) M warfarin sodium, respectively. The proposed procedure was successfully applied for assay of warfarin sodium in its pharmaceutical formulation "hemofarin tablets", human serum and urine without the necessity for sample pretreatment or time-consuming extraction or evaporation steps, prior to assay of the drug. Limits of detection of 1.1 x 10(-9) and 1.3 x 10(-8) M warfarin sodium were achieved, while limits of quanitation of 3.7 x 10(-9) and 4.3 x 10(-s) M warfarin sodium were estimated in human serum and urine, respectively. The pharmacokinetic profiles of the drug were studied and the estimated pharmacokinetic parameters were favorably compared with those reported in literature. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:63 / 69
页数:7
相关论文
共 26 条
[1]   DETERMINATION OF (R) AND (S) WARFARIN IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING PRECOLUMN DERIVATIZATION [J].
AYCARD, M ;
LETELLIER, S ;
MAUPAS, B ;
GUYON, F .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1992, 15 (12) :2175-2182
[2]   High-performance liquid-chromatographic determination of warfarin enantiomers in plasma with automated on-line sample enrichment [J].
Boppana, VK ;
Schaefer, WH ;
Cyronak, MJ .
JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 2002, 54 (1-3) :315-326
[3]   A SIMPLIFIED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR DIRECT DETERMINATION OF WARFARIN ENANTIOMERS AND THEIR PROTEIN-BINDING IN STROKE PATIENTS [J].
CAI, WM ;
HATTON, J ;
PETTIGREW, LC ;
DEMPSEY, RJ ;
CHANDLER, MHH .
THERAPEUTIC DRUG MONITORING, 1994, 16 (05) :509-512
[4]   Determination of warfarin in waters and human plasma hy solid-phase room-temperature transmitted phosphorescence [J].
Capitán-Vallvey, LF ;
Deheidel, MKA ;
Avidad, R .
ARCHIVES OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 1999, 37 (01) :1-6
[5]  
CHAN K, 1988, METHOD FIND EXP CLIN, V10, P699
[6]   HPLC determination of warfarin and acenocoumarol in raw materials and pharmaceuticals [J].
De Orsi, D ;
Gagliardi, L ;
Turchetto, L ;
Tonelli, D .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 17 (4-5) :891-895
[7]   Direct determination of praziquantel in pharmaceutical formulations and human plasma by cathodic adsorptive stripping differential-pulse voltammetry [J].
Ghoneim, MM ;
Mabrouk, MM ;
Tawfik, A .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 30 (04) :1311-1318
[8]   Direct potentiometry and potentiotitrimetry of warfarin and ibuprofen in pharmaceutical preparations using PVC ferroin-based membrane sensors [J].
Hassan, SSM ;
Mahmoud, WH ;
Abdel-Samad, MS .
MIKROCHIMICA ACTA, 1998, 129 (3-4) :251-257
[10]  
KLAASSEN CD, 1986, CASARETT DOULLS TOXI