Cemented versus Uncemented Hemiarthroplasty for Displaced Femoral Neck Fractures: 5-year Followup of a Randomized Trial

被引:172
作者
Langslet, Ellen [1 ,2 ]
Frihagen, Frede [2 ]
Opland, Vidar [1 ]
Madsen, Jan Erik [2 ,3 ]
Nordsletten, Lars [2 ,3 ]
Figved, Wender [1 ,3 ]
机构
[1] Vestre Viken Hosp Trust, Baerum Hosp, Dept Orthopaed, N-1309 Rud, Norway
[2] Oslo Univ Hosp, Dept Orthopaed, Oslo, Norway
[3] Univ Oslo, Fac Med, Oslo, Norway
关键词
HIP-ARTHROPLASTY; OPERATIVE MANAGEMENT; MORTALITY;
D O I
10.1007/s11999-013-3308-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Displaced femoral neck fractures usually are treated with hemiarthroplasty. However, the degree to which the design of the implant used (cemented or uncemented) affects the outcome is not known and may be therapeutically important. In this randomized controlled trial, we sought to compare cemented with cementless fixation in bipolar hemiarthroplasties at 5 years in terms of (1) Harris hip scores; (2) femoral fractures; (3) overall health outcomes using the Barthel Index and EQ-5D scores; and (4) complications, reoperations, and mortality since our earlier report on this cohort at 1-year followup. We present followup at a median of 5 years after surgery (range, 56-65 months) from a randomized trial comparing a cemented hemiarthroplasty (112 hips) with an uncemented, hydroxyapatite-coated hemiarthroplasty (108 hips), both with a bipolar head. Results were previously reported at 1-year followup. Harris hip scores, Barthel Index, and EQ-5D scores were assessed by one research nurse and one orthopaedic surgeon. Complications and reoperations were determined by chart review and radiographs examined by three orthopaedic surgeons. Sixty patients (56%) had died in the cemented group and 63 (60%) in the uncemented group. Respectively, three and two patients (2.7% and 1.9%) were completely lost to followup. Harris hip scores at 5 years were higher in the uncemented group than in the cemented group (86.2 versus 76.3; mean difference 9.9; 95% confidence interval [CI], 1.9-17.9). The prevalence of postoperative periprosthetic femoral fractures was 7.4% in the uncemented group and 0.9% in the cemented group (hazard ratio [HR], 9.3; 95% CI, 1.16-74.5). Barthel Index and EQ-5D scores were not different between the groups. Between 1 and 5 years, we found no additional infections or dislocations. The mortality rate was not different between the groups (HR, 1.2; 95% CI, 0.82-1.7). Both arthroplasties may be used with good medium-term results after displaced femoral neck fractures. The uncemented hemiarthroplasty may result in higher hip scores but appears to carry an unacceptably high risk of later femoral fractures. Level I, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.
引用
收藏
页码:1291 / 1299
页数:9
相关论文
共 26 条
[1]   Operative management of displaced femoral neck fractures in elderly patients - An international survey [J].
Bhandari, M ;
Devereaux, PJ ;
Tornetta, P ;
Swiontkowski, MF ;
Berry, DJ ;
Haidukewych, G ;
Schemitsch, EH ;
Hanson, BP ;
Koval, K ;
Dirschl, D ;
Leece, P ;
Keel, M ;
Petrisor, B ;
Heetveld, M ;
Guyatt, GH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (09) :2122-2130
[2]  
Dolan P, 1996, HEALTH ECON, V5, P141, DOI 10.1002/(SICI)1099-1050(199603)5:2<141::AID-HEC189>3.0.CO
[3]  
2-N
[4]   18 years of results with cemented primary hip prostheses in the Norwegian Arthroplasty Register Concerns about some newer implants [J].
Espehaug, Birgitte ;
Furnes, Ove ;
Engesaeter, Lars B. ;
Havelin, Leif I. .
ACTA ORTHOPAEDICA, 2009, 80 (04) :402-412
[5]   Cemented versus Uncemented Hemiarthroplasty for Displaced Femoral Neck Fractures [J].
Figved, Wender ;
Opland, Vidar ;
Frihagen, Frede ;
Jervidalo, Tore ;
Madsen, Jan Erik ;
Nordsletten, Lars .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2009, 467 (09) :2426-2435
[6]   Outcome after femoral neck fractures: A comparison of Harris Hip Score, Eq-5d and Barthel Index [J].
Frihagen, Frede ;
Grotle, Margreth ;
Madsen, Jan Erik ;
Wyller, Torgeir Bruun ;
Mowinckel, Petter ;
Nordsletten, Lars .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2008, 39 (10) :1147-1156
[7]   The Charnley versus the Spectron hip prosthesis - Clinical evaluation of a randomized, prospective study of 2 different hip implants [J].
Garellick, G ;
Malchau, H ;
Herberts, P .
JOURNAL OF ARTHROPLASTY, 1999, 14 (04) :407-413
[8]   More re-operations after uncemented than cemented hemiarthroplasty used in the treatment of displaced fractures of the femoral neck An observational study of 11 116 hemiarthroplasties from a national register [J].
Gjertsen, J-E. ;
Lie, S. A. ;
Vinje, T. ;
Engesaeter, L. B. ;
Hallan, G. ;
Matre, K. ;
Furnes, O. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (08) :1113-1119
[9]   Medium- and long-term performance of 11,516 uncemented primary femoral stems from the Norwegian arthroplasty register [J].
Hallan, G. ;
Lie, S. A. ;
Furnes, O. ;
Engesaeter, L. B. ;
Vollset, S. E. ;
Havelin, L. I. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2007, 89B (12) :1574-1580