Microwave-assisted, grafting polymerization preparation of strong cation exchange nylon 6 capillary-channeled polymer fibers and their chromatographic properties

被引:22
作者
Jiang, Liuwei [1 ,2 ]
Marcus, R. Kenneth [1 ]
机构
[1] Clemson Univ, Dept Chem, Biosyst Res Complex, Clemson, SC 29634 USA
[2] Jordi Labs, 200 Gilbert St, Mansfield, MA 02048 USA
基金
美国国家科学基金会;
关键词
Capillary-channeled polymer; Fiber; Surface modification; Microwave-assisted polymerization; Ion exchange; Chromatography; PERFORMANCE LIQUID-CHROMATOGRAPHY; C-CP FIBERS; LIPID-TETHERED LIGANDS; STATIONARY-PHASE; SURFACE MODIFICATION; PROTEIN SEPARATIONS; HIGH-CAPACITY; MONOLITHS; COLUMNS; CRYOGEL;
D O I
10.1016/j.aca.2017.04.033
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Native nylon 6 C-CP fibers were modified with 2-acrylamido-2-methylpropanesulfonic acid (AMPS) via the microwave-assisted grafting polymerization to affect a strong cation exchange stationary phase. Various concentrations of AMPS and the initiator potassium persulfate (KPS) were used in the modifications. The resultant nylon-SO3H fibers were characterized by Attenuated total reflection-Fourier transform infrared spectroscopy (ATR-FTIR), scanning electron microscopy (SEM) and acid-base titrations. The chromatographic properties, including column permeability, protein separation quality, and protein binding capacity, of the nylon-SO3H fiber columns were also studied. The cation exchange ligand densities on the modified fibers (-SO3H) were determined to be 50-317 mu mol g(-1), in comparison to the cation (-COOH) density of 28 mu mol g(-1) of native nylon 6 fibers. The modified fiber phase showed increased lysozyme dynamic loading capacities (up to similar to 13 mg mL(-1) bed volume) at a linear velocity of similar to 90 cm min(-1), while native nylon 6 showed only similar to 1 mg mL(-1) lysozyme loading capacity. Fast (30 s -3 min) gradient separations of myoglobin, alpha-chymotrypsinogen A, and lysozyme were achieved on nylon-SO3H columns, with the separation resolution and peak capacity characterized. The efficiency of surface re-equilibration was probed with an eye toward using the phase as the second dimension in comprehensive two-dimensional liquid chromatography (2D-LC). The results indicate that this nylon-SO3H fiber phase has a good deal of potential for use in high-throughput analytical and preparative protein separations. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:52 / 64
页数:13
相关论文
共 54 条
[11]   Preliminary assessment of the modification of polystyrene-divinylbenzene resin with lipid-tethered ligands for selective separations [J].
Haupt-Renaud, Paul ;
Jiang, Liuwei ;
Marcus, Richard Kenneth .
JOURNAL OF SEPARATION SCIENCE, 2016, 39 (20) :3868-3879
[12]   Nylon surface modification: 2. Nylon-supported composite films [J].
Herrera-Alonso, M ;
McCarthy, TJ ;
Jia, XQ .
LANGMUIR, 2006, 22 (04) :1646-1651
[13]   MECHANISM AND KINETICS OF THE PERSULFATE-INITIATED POLYMERIZATION OF ACRYLAMIDE [J].
HUNKELER, D .
MACROMOLECULES, 1991, 24 (09) :2160-2171
[14]   Nylon surface modification. Part 1. Targeting the amide groups for selective introduction of reactive functionalities [J].
Jia, Xinqiao ;
Herrera-Alonso, Margarita ;
McCarthy, Thomas J. .
POLYMER, 2006, 47 (14) :4916-4924
[15]  
Jiang L., 2015, ANAL BIOANAL CHEM, P1
[16]   Microwave-assisted grafting polymerization modification of nylon 6 capillary-channeled polymer fibers for enhanced weak cation exchange protein separations [J].
Jiang, Liuwei ;
Marcus, R. Kenneth .
ANALYTICA CHIMICA ACTA, 2017, 954 :129-139
[17]   Polyethylenimine modified poly(ethylene terephthalate) capillary channeled-polymer fibers for anion exchange chromatography of proteins [J].
Jiang, Liuwei ;
Jin, Yi ;
Marcus, R. Kenneth .
JOURNAL OF CHROMATOGRAPHY A, 2015, 1410 :200-209
[18]   Evaluation of synthesized lipid tethered ligands for surface functionalization of polypropylene capillary-channeled polymer fiber stationary phases [J].
Jiang, Liuwei ;
Schadock-Hewitt, Abby J. ;
Zhang, Lynn X. ;
Marcus, R. Kenneth .
ANALYST, 2015, 140 (05) :1523-1534
[19]   Biotin-functionalized poly(ethylene terephthalate) capillary-channeled polymer fibers as HPLC stationary phase for affinity chromatography [J].
Jiang, Liuwei ;
Marcus, R. Kenneth .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (03) :939-951
[20]   Chromatographic media for bioseparation [J].
Jungbauer, A .