Selective solid-phase extraction of Ni(II) by an ion-imprinted polymer from water samples

被引:127
作者
Saraji, Mohammad [1 ]
Yousefi, Hamideh [1 ]
机构
[1] Isfahan Univ Technol, Dept Chem, Esfahan 8415483111, Iran
关键词
Ion-imprinted polymer; Solid-phase extraction; Nickel ion; Atomic absorption spectrometry; ATOMIC-ABSORPTION-SPECTROMETRY; SURFACTANT-COATED ALUMINA; ONLINE PRECONCENTRATION; ENVIRONMENTAL-SAMPLES; ACTIVATED CARBON; TRACE AMOUNTS; SEPARATION; DITHIZONE; SORBENT; COPPER;
D O I
10.1016/j.jhazmat.2009.01.111
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A new ion-imprinted polymer (IIP) material was synthesized by copolymerization of 4-vinylpyridine as monomer, ethyleneglycoldimethacrylate as crosslinking agent and 2,2'-azobis-sobutyronitrile as initiator in the presence of Ni-dithizone complex. The IIP was used as sorbent in a solid-phase extraction column. The effects of sampling volume, elution conditions, sample pH and sample flow rate on the extraction of Ni ions form water samples were studied. The maximum adsorption capacity and the relative selectivity coefficients of imprinted polymer for Ni(II)/Co(II), Ni(II)/Cu(II) and Ni(II)/Cd(II) were calculated. Compared with non-imprinted polymer particles, the lip had higher selectivity for Ni(II). The relative selectivity factor (alpha(r)) values of Ni(II)/Co(II), Ni(II)/Cu(II) and Ni(II)/Cd(II) were 21.6, 54.3, and 22.7, respectively. which are greater than 1. The relative standard deviation of the five replicate determinations of Ni(II) was 3.4%. The detection limit for 150 mL. of sample was 1.6 mu g L-1 using flame atomic absorption spectrometry. The developed method was successfully applied to the determination of trace nickel in water samples with satisfactory results. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:1152 / 1157
页数:6
相关论文
共 31 条
[1]   Optimizing the immobilized dithizone on surfactant-coated alumina as a new sorbent for determination of silver [J].
Absalan, G ;
Goudi, AA .
SEPARATION AND PURIFICATION TECHNOLOGY, 2004, 38 (03) :209-214
[2]  
Aktas YK, 2005, REV ROUM CHIM, V50, P277
[3]   Optimization of a new activated carbon based sorbent for on-line preconcentration and trace determination of nickel in aquatic samples using mixed-level orthogonal array design [J].
Bagheri, H ;
Saraji, M ;
Naderi, M .
ANALYST, 2000, 125 (09) :1649-1654
[4]   Preconcentration of copper using double-imprinted polymer via solid phase extraction [J].
Birlik, E ;
Ersöz, A ;
Denizli, A ;
Say, R .
ANALYTICA CHIMICA ACTA, 2006, 565 (02) :145-151
[5]   Solid-phase extraction of iron(III) with an ion-imprinted functionalized silica gel sorbent prepared by a surface imprinting technique [J].
Chang, Xijun ;
Jiang, Na ;
Zheng, Hong ;
He, Qun ;
Hu, Zheng ;
Zhai, Yunhui ;
Cui, Yuemei .
TALANTA, 2007, 71 (01) :38-43
[6]   Solid phase selective separation and preconcentration of Cu(II) by Cu(II)-imprinted polyrnethacrylic microbeads [J].
Dakova, Ivanka ;
Karadjova, Irina ;
Ivanov, No ;
Georgieva, Ventsislava ;
Evtimova, Bisera ;
Georgiev, George .
ANALYTICA CHIMICA ACTA, 2007, 584 (01) :196-203
[7]   Ni(II) ion-imprinted solid-phase extraction and preconcentration in aqueous solutions by packed-bed columns [J].
Ersöz, A ;
Say, R ;
Denizli, A .
ANALYTICA CHIMICA ACTA, 2004, 502 (01) :91-97
[8]   An ion-imprinted functionalized silica gel sorbent prepared by a surface imprinting technique combined with a sol-gel process for selective solid-phase extraction of cadmium(II) [J].
Fang, GZ ;
Tan, J ;
Yan, XP .
ANALYTICAL CHEMISTRY, 2005, 77 (06) :1734-1739
[9]   Separation of matrix by means of biosorption for flow-injection chemiluminescent determination of trace amounts of Pt(IV) in natural waters [J].
Godlewska-Zylkiewicz, Beata ;
Malejko, Julita ;
Halaburda, Piotr ;
Lesniewska, Barbara ;
Kojlo, Anatol .
MICROCHEMICAL JOURNAL, 2007, 85 (02) :314-320
[10]   IMMOBILIZATION OF DITHIZONE ON SURFACTANT-COATED ALUMINA FOR PRECONCENTRATION OF METAL-IONS [J].
HIRAIDE, M ;
SOROURADIN, MH ;
KAWAGUCHI, H .
ANALYTICAL SCIENCES, 1994, 10 (01) :125-127