Technology developments for ITER in-vessel equilibrium magnetic sensors

被引:16
作者
Chitarin, G. [1 ,2 ]
Delogu, R.
Gallo, A. [2 ]
Peruzzo, S.
机构
[1] Univ Padua, Consorzio RFX, Assoc EURATOM ENEA Fus, Corso Stati Uniti 4, I-35127 Padua, Italy
[2] Univ Padua, Dept Engn & Management, I-36100 Vicenza, Italy
关键词
ITER; Magnetic diagnostics; Equilibrium coils; Magnetic Sensors; LTCC; RADIATION; CABLES;
D O I
10.1016/j.fusengdes.2008.11.022
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The ITER magnetic equilibrium sensors will be installed in a hostile environment characterized by severe neutron radiation and heat loads, which can cause undesired spurious signals and compromise the accuracy of the measurements obtained by time-integration. The paper deals with the construction and tests of prototype in-vessel pick-up coils, which have been developed aiming at the reduction of the adverse effects of neutron radiation by using suitable materials and by minimizing the thermal gradients. A first solution based on a winding made of a flexible ceramic-coated conductor (instead of a Mineral Insulated Cables) and "impregnated" with ceramic filler has been implemented and tested. A second solution based on coils constituted by a stack of circuits printed on a ceramic substrate sintered in one piece has also been developed and tested with positive results. The paper describes the design developments, the rationale for the test and discusses the results and the developments necessary for the production of reliable equilibrium sensors for ITER. (c) 2008 G. Chitarin. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:593 / 598
页数:6
相关论文
共 7 条
[1]   Design developments for the ITER in-vessel equilibrium pick-up coils and halo current sensors [J].
Chitarin, G. ;
Grando, L. ;
Peruzzo, S. ;
Taccon, C. .
FUSION ENGINEERING AND DESIGN, 2007, 82 (5-14) :1341-1347
[2]  
HOW J, 2007, ITERD2234RH IDM
[3]  
PERUZZO S, 2007, P INT WORKSH BURN PL
[4]   Magnetic probe construction using thick-film technology [J].
Takahashi, H ;
Sakakibara, S ;
Kubota, Y ;
Yamada, H .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (08) :3249-3259
[5]   Radiation-induced thermoelectric sensitivity (RITES) in ITER prototype magnetic sensors [J].
Vayakis, G ;
Sugie, T ;
Kondoh, T ;
Nishitani, T ;
Ishitsuka, E ;
Yamauchi, M ;
Kawashima, H ;
Shikama, T .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (10) :4324-4327
[6]   Induced voltages and currents in copper and stainless steel core mineral insulated cables due to radiation and thermal gradients [J].
Vermeeren, L. ;
Wéber, M. .
FUSION ENGINEERING AND DESIGN, 2007, 82 (5-14) :1185-1191
[7]   TIEMF in unirradiated Cu cored MI cables: Microstructure [J].
Vila, R. ;
Hodgson, E. R. .
FUSION ENGINEERING AND DESIGN, 2007, 82 (5-14) :1271-1276