GaitKeeper: A System for Measuring Canine Gait

被引:18
作者
Ladha, Cassim [1 ]
O'Sullivan, Jack [1 ]
Belshaw, Zoe [2 ]
Asher, Lucy [1 ]
机构
[1] Newcastle Univ, Ctr Behav & Evolut, Henry Wellcome Bldg, Newcastle Upon Tyne NE2 4HH, Tyne & Wear, England
[2] Univ Nottingham, Sch Vet Med & Sci, Sutton Bonington Campus, Loughborough LE12 5RD, Leics, England
基金
英国生物技术与生命科学研究理事会;
关键词
gait; locomotion; stride segmentation; accelerometer; dog; exercise; movement science; inertial measurement unit (IMU); gyroscope; FORCE PLATE ANALYSIS; ACTIVITY MONITOR; EVENT DETECTION; PARAMETERS; WALKING; DOGS; OSTEOARTHRITIS; LAMENESS; LOCOMOTION; AGREEMENT;
D O I
10.3390/s17020309
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
It is understood gait has the potential to be used as a window into neurodegenerative disorders, identify markers of subclinical pathology, inform diagnostic algorithms of disease progression and measure the efficacy of interventions. Dogs' gaits are frequently assessed in a veterinary setting to detect signs of lameness. Despite this, a reliable, affordable and objective method to assess lameness in dogs is lacking. Most described canine lameness assessments are subjective, unvalidated and at high risk of bias. This means reliable, early detection of canine gait abnormalities is challenging, which may have detrimental implications for dogs' welfare. In this paper, we draw from approaches and technologies used in human movement science and describe a system for objectively measuring temporal gait characteristics in dogs (step-time, swing-time, stance-time). Asymmetries and variabilities in these characteristics are of known clinical significance when assessing lameness but presently may only be assessed on coarse scales or under highly instrumented environments. The system consists an inertial measurement unit, containing a 3-axis accelerometer and gyroscope coupled with a standardized walking course. The measurement unit is attached to each leg of the dog under assessment before it is walked around the course. The data by the measurement unit is then processed to identify steps and subsequently, micro-gait characteristics. This method has been tested on a cohort of 19 healthy dogs of various breeds ranging in height from 34.2 cm to 84.9 cm. We report the system as capable of making precise step delineations with detections of initial and final contact times of foot-to-floor to a mean precision of 0.011 s and 0.048 s, respectively. Results are based on analysis of 12,678 foot falls and we report a sensitivity, positive predictive value and F-score of 0.81, 0.83 and 0.82 respectively. To investigate the effect of gait on system performance, the approach was tested in both walking and trotting with no significant performance deviation with 7249 steps reported for a walking gait and 4977 for a trotting gait. The number of steps reported for each leg were approximately equal and this consistency was true in both walking and trotting gaits. In the walking gait 1965, 1790, 1726 and 1768 steps were reported for the front left, front right, hind left and hind right legs respectively. 1361, 1250, 1176 and 1190 steps were reported for each of the four legs in the trotting gait. The proposed system is a pragmatic and precise solution for obtaining objective measurements of canine gait. With further development, it promises potential for a wide range of applications in both research and clinical practice.
引用
收藏
页数:17
相关论文
共 54 条
[1]   Reliability of F-Scan in-shoe measurements of plantar pressure [J].
Ahroni, JH ;
Boyko, EJ ;
Forsberg, R .
FOOT & ANKLE INTERNATIONAL, 1998, 19 (10) :668-673
[2]   Temporal feature estimation during walking using miniature accelerometers: an analysis of gait improvement after hip arthroplasty [J].
Aminian, K ;
Rezakhanlou, K ;
De Andres, E ;
Fritsch, C ;
Leyvraz, PF ;
Robert, P .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1999, 37 (06) :686-691
[3]   A framework for the in vivo pathomechanics of osteoarthritis at the knee [J].
Andriacchi, TP ;
Mündermann, A ;
Smith, RL ;
Alexander, EJ ;
Dyrby, CO ;
Koo, S .
ANNALS OF BIOMEDICAL ENGINEERING, 2004, 32 (03) :447-457
[4]   Differences in Walking Pattern during 6-Min Walk Test between Patients with COPD and Healthy Subjects [J].
Annegarn, Janneke ;
Spruit, Martijn A. ;
Savelberg, Hans H. C. M. ;
Willems, Paul J. B. ;
van de Bool, Coby ;
Schols, Annemie M. W. J. ;
Wouters, Emiel F. M. ;
Meijer, Kenneth .
PLOS ONE, 2012, 7 (05)
[5]  
[Anonymous], 2010, MULTIMODAL CORPORA A
[6]   Pre- and postoperative force plate analysis of dogs with experimentally transected cranial cruciate ligaments treated using tibial plateau leveling osteotomy [J].
Ballagas, AJ ;
Montgomery, RD ;
Henderson, RA ;
Gillette, R .
VETERINARY SURGERY, 2004, 33 (02) :187-190
[7]   Fitting Linear Mixed-Effects Models Using lme4 [J].
Bates, Douglas ;
Maechler, Martin ;
Bolker, Benjamin M. ;
Walker, Steven C. .
JOURNAL OF STATISTICAL SOFTWARE, 2015, 67 (01) :1-48
[8]   Systematic Review of Outcome Measures Reported in Clinical Canine Osteoarthritis Research [J].
Belshaw, Zoe ;
Asher, Lucy ;
Dean, Rachel S. .
VETERINARY SURGERY, 2016, 45 (04) :480-487
[9]  
Benoussaad M., 2015, SENSORS, V16, P1
[10]   Is a standalone inertial measurement unit accurate and precise enough for quantification of movement symmetry in the horse? [J].
Brighton, Charlotte ;
Olsen, Emil ;
Pfau, Thilo .
COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2015, 18 (05) :527-532