Determination of copper in traditional coffee pot water samples by flame atomic absorption spectrometry and matrix matching calibration strategy after switchable solvent based liquid-phase microextraction

被引:6
作者
Ercan, Maral Selin Findikoglu [1 ]
Ayyildiz, Merve Firat [1 ]
Chormey, Dotse Selali [1 ]
Bakirdere, Sezgin [1 ,2 ]
机构
[1] Yildiz Tech Univ, Chem Dept, TR-34210 Istanbul, Turkey
[2] Turkish Acad Sci TUBA, Piyade St 27, TR-06690 Ankara, Turkey
关键词
Copper; FAAS; SS-LPME; SQT; Experimental design; SPECTROPHOTOMETRIC DETERMINATION; FAAS DETERMINATION; IONIC LIQUID; PRECONCENTRATION; EXTRACTION; FOOD; CHROMIUM; ALUMINUM; VANADIUM; NICKEL;
D O I
10.1007/s10661-020-08729-w
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Traditional copper coffee pots are widely used in these modern times and daily consumption of coffee brewed in overused/old pots increases the risk of copper ingestion. This study employed a green switchable solvent-based liquid-phase microextraction (SS-LPME) method to isolate and preconcentrate copper from water boiled in coffee pots. Copper was determined by a flame atomic absorption spectrometry (FAAS) system coupled with a slotted quartz tube (SQT). 1,5-Diphenylcarbazone was added to aqueous samples to form a complex with copper before the extraction step. Box-Behnken experimental design was applied to select optimum conditions of the extraction method that were used to validate the analytical method. The limits of quantification and detection of the optimized SS-LPME-SQT-FAAS method were determined as 9.1 and 2.7 mu g/L, respectively. Water samples boiled in traditional coffee pots were spiked at different concentrations and analyzed to ascertain the method's accuracy and applicability to real samples. Satisfactory recovery results obtained in the range of 92-107% established good accuracy, and percent relative standard deviations lower than 8.0% also proved high precision.
引用
收藏
页数:7
相关论文
共 24 条
[1]   Determination of ultra trace levels of copper in food samples by a highly sensitive adsorptive stripping voltammetric method [J].
Abbasi, Shahryar ;
Khani, Hossein ;
Tabaraki, Reza .
FOOD CHEMISTRY, 2010, 123 (02) :507-512
[2]   Dispersive liquid-liquid microextraction of Fe(II) and Cu(II) with diethyldithiocarbamate and their simultaneous spectrophotometric determination using mean centering of ratio spectra [J].
Arvand, M. ;
Bozorgzadeh, E. ;
Zanjanchi, M. A. ;
Shariati, Sh. .
JOURNAL OF ANALYTICAL CHEMISTRY, 2014, 69 (03) :243-247
[3]   Ionic liquids versus ionic liquid-based surfactants in dispersive liquid-liquid microextraction for determining copper in water by flame atomic absorption spectrometry [J].
Ayala-Cabrera, Juan F. ;
Trujillo-Rodriguez, Maria J. ;
Pino, Veronica ;
Hernandez-Torres, Oscar M. ;
Afonso, Ana M. ;
Sirieix-Plenet, Juliette .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2016, 96 (02) :101-118
[4]  
Biparva P., 2012, MICROEXTRACTION TECH, P61
[5]   Ultrasound-assisted emulsification solidified floating organic drop microextraction for the determination of trace amounts of copper in water samples [J].
Chang, Qingyun ;
Zhang, Jingwen ;
Du, Xin ;
Ma, Jingjun ;
Li, Jingci .
FRONTIERS OF ENVIRONMENTAL SCIENCE & ENGINEERING IN CHINA, 2010, 4 (02) :187-195
[6]   The use of diluted formic acid in sample preparation for macro- and microelements determination in foodstuff samples using ICP OES [J].
de Oliveira, Aline Fernandes ;
da Silva, Caroline Santos ;
Bianchi, Silmara Rossana ;
Araujo Nogueira, Ana Rita .
JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2018, 66 :7-12
[7]  
Ellingsen DG, 2015, HANDBOOK ON THE TOXICOLOGY OF METALS, VOL I & II, 4TH EDITION, P765, DOI 10.1016/B978-0-444-59453-2.00035-4
[8]   Ionic Liquid as a Ferrofluid Carrier for Dispersive Solid Phase Extraction of Copper from Food Samples [J].
Farahani, Malihe Davudabadi ;
Shemirani, Farzaneh ;
Ramandi, Negin Fasih ;
Gharehbaghi, Maysam .
FOOD ANALYTICAL METHODS, 2015, 8 (08) :1979-1989
[9]   Optimization and application of homogeneous liquid-liquid extraction in preconcentration of copper (II) in a ternary solvent system [J].
Farajzadeh, Mir Ali ;
Bahram, Morteza ;
Zorita, Saioa ;
Mehr, Behzad Ghorbani .
JOURNAL OF HAZARDOUS MATERIALS, 2009, 161 (2-3) :1535-1543
[10]   Vortex-assisted switchable liquid-liquid microextraction for the preconcentration of cadmium in environmental samples prior to its determination with flame atomic absorption spectrometry [J].
Firat, Merve ;
Bodur, Suleyman ;
Tisli, Busra ;
Ozlu, Cansu ;
Chormey, Dotse Selali ;
Turak, Fatma ;
Bakirdere, Sezgin .
ENVIRONMENTAL MONITORING AND ASSESSMENT, 2018, 190 (07)