Multi-wavelength pulse plethysmography for real-time drug delivery monitoring

被引:1
作者
Adhikari, Pratik [1 ]
Magana, Isidro B. [1 ]
O'Neal, D. Patrick [1 ]
机构
[1] Louisiana Tech Univ, Dept Biomed Engn, Ruston, LA 71272 USA
来源
OPTICAL DIAGNOSTICS AND SENSING XIV: TOWARD POINT-OF-CARE DIAGNOSTICS | 2014年 / 8951卷
关键词
D O I
10.1117/12.2040064
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A novel multi-wavelength photoplethysmograph (PPG), previously utilized to quantify optically absorptive circulating gold nanoparticles, has demonstrated the potential to enhance therapeutic treatment predictability as pharmacokinetic metrics are provided throughout the intravenous delivery phase of quinine in real-time. This report demonstrates how the PPG could be used to assess the real-time bioavailability of other types of intravenously delivered optically-absorbing nanoparticles and drugs. The drug currently under investigation is anti-malarial quinine (absorption peak similar to 350 nm). We describe how the algorithm has been adapted to quantify the concentration of quinine in the pulsatile, circulating blood based on its extinction at three wavelengths (340, 660 and 940 nm). We show an example of the system collecting data representing the baseline, injection, and the clearance phases. An examination of the raw signal suggests that the system is well suited to sense the concentration of quinine in the therapeutic range (10mg/kg).
引用
收藏
页数:5
相关论文
共 50 条
[41]   Multi-wavelength fluorometry for anaerobic digestion process monitoring [J].
Morel, E ;
Santamaria, K ;
Perrier, M ;
Guiot, SR ;
Tartakovsky, B .
WATER SCIENCE AND TECHNOLOGY, 2005, 52 (1-2) :465-471
[42]   Multi-wavelength radio monitoring of EGRET sources and candidates [J].
Edwards, PG ;
Lovell, JEJ ;
Hartman, RC ;
Tornikoski, M ;
Lainela, M ;
McCulloch, PM ;
Gaensler, BM ;
Hunstead, RW .
PROCEEDINGS OF THE FOURTH COMPTON SYMPOSIUM, PTS 1 AND 2: PT 1: THE COMPTON OBSERVATORY IN REVIEW; PT 2: PAPERS AND PRESENTATIONS, 1997, (410) :1428-1432
[43]   Multi-wavelength photoplethysmography method for skin arterial pulse extraction [J].
Liu, Jing ;
Yan, Bryan Ping-Yen ;
Dai, Wen-Xuan ;
Ding, Xiao-Rong ;
Zhang, Yuan-Ting ;
Zhao, Ni .
BIOMEDICAL OPTICS EXPRESS, 2016, 7 (10) :4313-4326
[44]   Constructing a Real-Time Prescription Drug Monitoring System [J].
Park, Young-Taek ;
Lee, Youn Tae ;
Jo, Emmanuel C. .
HEALTHCARE INFORMATICS RESEARCH, 2016, 22 (03) :178-185
[45]   Real-time access to prescription drug monitoring databases [J].
Wilsey, Barth ;
Prasad, Hannah .
CANADIAN MEDICAL ASSOCIATION JOURNAL, 2012, 184 (16) :1767-1768
[46]   Multi-Wavelength Pulse Oximeter Is Not Suitable for Adjusting DLCO Measurements [J].
Ruppel, Gregg L. ;
Wilson, Holly A. ;
Gall, Vanessa K. ;
Hempkens, John A. .
RESPIRATORY CARE, 2011, 56 (08) :1115-1121
[47]   Switchable multi-wavelength pulse fiber laser with mode conversion [J].
Guo, Yinghao ;
Jiang, Youchao ;
Gao, Jiao ;
Liu, Wenqian ;
Shen, Ya ;
Ren, Wenhua ;
Ren, Guobin .
INFRARED PHYSICS & TECHNOLOGY, 2025, 145
[48]   Real-time monitoring of HIFU treatment using pulse inversion [J].
Song, Jae Hee ;
Yoo, Yangmo ;
Song, Tai-Kyong ;
Chang, Jin Ho .
PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (15) :5333-5350
[49]   Real-time Monitoring and Control System for Femtosecond Pulse Lasers [J].
Jang, Heesuk ;
Lee, Keunwoo ;
Han, Seongheum ;
Lee, Joohyung ;
Kim, Young-Jin ;
Kim, Seung-Woo .
2013 CONFERENCE ON LASERS AND ELECTRO-OPTICS PACIFIC RIM (CLEO-PR), 2013,
[50]   Wide dynamic range and real-time reagent identification and imaging using multi-wavelength terahertz parametric generation and machine learning [J].
Kosuke Murate ;
Sota Mine ;
Yuki Torii ;
Hyuga Inoue ;
Kodo Kawase .
Scientific Reports, 13