Evaluation of four airway training manikins as simulators for inserting the LMA Classic™

被引:35
作者
Silsby, J. [1 ]
Jordan, G. [1 ]
Bayley, G. [1 ]
Cook, T. M. [1 ]
机构
[1] Royal United Hosp, Dept Anaesthesia, Bath BA1 3NG, Avon, England
关键词
D O I
10.1111/j.1365-2044.2006.04643.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Airway manikins have traditionally been used for teaching mask ventilation and tracheal intubation. There is an increasing need to use manikins for training in procedures such as insertion of the laryngeal mask airway. We have assessed four new airway training manikins (latest versions of the Airway Trainer (TM) (Laerdal, Norway), Air-way Management Trainer (TM) (Ambu, UK), 'Bill 1'(TM) (VBM, Germany) and Airsim (TM) (Trucorp, Ireland)) as simulators for insertion of the LMA Classic (TM) laryngeal mask airway. Twenty volunteer anaesthetists inserted a size-4 laryngeal mask airway five times into each of the four manikins, in random order. Each insertion was assessed using objective and subjective tests. Subjective assessment varied widely but overall assessment indicated that the Airway Management Trainer was the poorest simulator for insertion of the laryngeal mask airway. The 'Bill 1' and Airsim manikins performed best as simulators for insertion of the laryngeal mask airway, although realistic ventilation with 'Bill 1' was not possible.
引用
收藏
页码:576 / 579
页数:4
相关论文
共 6 条
  • [1] [Anonymous], 2000, RESUSCITATION, V46, P115
  • [2] Pressure in laryngeal mask airway cuffs
    Brain, AIJ
    [J]. ANAESTHESIA, 1996, 51 (06) : 603 - 603
  • [3] Novel airway devices: Spoilt for choice?
    Cook, TM
    [J]. ANAESTHESIA, 2003, 58 (02) : 107 - 110
  • [4] Comparison of different laryngeal mask airways in a resuscitation model
    Genzwürker, H
    Hundt, A
    Finteis, T
    Ellinger, K
    [J]. ANASTHESIOLOGIE INTENSIVMEDIZIN NOTFALLMEDIZIN SCHMERZTHERAPIE, 2003, 38 (02): : 94 - 101
  • [5] STONE BJ, 1994, ANAESTHESIA, V49, P3
  • [6] Clinical assessment of the single use laryngeal mask airway - the LMA-Unique
    Verghese, C
    Berlet, J
    Kapila, A
    Pollard, R
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 1998, 80 (05) : 677 - 679