CdZnTe detector arrays for low-dose x-ray fluoroscopy

被引:0
|
作者
Heanue, JA [1 ]
Pearson, DA [1 ]
Melen, RE [1 ]
机构
[1] Cardiac Mariners Inc, Los Gatos, CA 95030 USA
来源
MEDICAL APPLICATIONS OF PENETRATING RADIATION | 1999年 / 3770卷
关键词
CdZnTe; detector; x-ray; cardiac angiography; fluoroscopy;
D O I
10.1117/12.368174
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The Scanning-Beam Digital X-ray (SBDX) system promises low-dose cardiac fluoroscopy and angiography with excellent image quality. The system demands a detector capable of high count rates and excellent detection efficiency. Cadmium zinc telluride (CdZnTe) is well suited to these requirements. The SBDX detector comprises sixteen 3-mm-thick, 13.5 mm x 13.5 mm tiles arranged in a 4 x 4 array. Each tile has 144 imaging elements. Thus, the entire detector measures 54.0 mm x 54.0 mm and includes 2,304 imaging elements on a 1.125 mm pitch. Because the SBDX system has a geometric magnification of 3.3, the imaging-element size is consistent with a system spatial-resolution of 2.2 1p/mn The 3-mm thickness is chosen to guarantee a stopping efficiency of more than 90% at 120 kVp. Each detector tile is flip-chip mounted to a custom-designed integrated circuit (IC) using indium bump bonding techniques. Fabricated in a 1.2-mu m CMOS process, the IC includes high-speed photon-counting circuitry that operates at rates up to 5 x 10(6) counts/s.mm(2). The circuitry is designed both to maximize the achievable count-rate and to minimize false double counts due to charge sharing between elements. Testing confirms that the detector performs with minimum cross talk between elements at count rates in excess of 2 x 10(6) counts/s.mm(2). Measurements of the detective quantum efficiency (DQE) are presented. The relationship between material properties and detector performance is also discussed.
引用
收藏
页码:114 / 121
页数:8
相关论文
共 50 条
  • [1] CdZnTe and CdTe detector arrays for hard X-ray and gamma-ray astronomy
    Stahle, CM
    Parker, BH
    Parsons, AM
    Barbier, LM
    Barthelmy, SD
    Gehrels, NA
    Palmer, DM
    Snodgrass, SJ
    Tueller, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 436 (1-2) : 138 - 145
  • [2] Experimental evaluation of a novel CdZnTe flat-panel X-ray detector for digital radiography and fluoroscopy
    Tokuda, S
    Adachi, S
    Sato, T
    Yoshimuta, T
    Nagata, H
    Uehara, K
    Izumi, Y
    Teranuma, O
    Yamada, S
    MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 140 - 147
  • [3] THE X-RAY FOVEA, A DEVICE FOR REDUCING X-RAY DOSE IN FLUOROSCOPY
    LABBE, MS
    CHIU, MY
    RZESZOTARSKI, MS
    BANIHASHEMI, AR
    WILSON, DL
    MEDICAL PHYSICS, 1994, 21 (03) : 471 - 481
  • [4] Fast CdTe and CdZnTe Semiconductor Detector Arrays for Spectroscopic X-Ray Imaging
    Brambilla, Andrea
    Ouvrier-Buffet, P.
    Gonon, G.
    Rinkel, J.
    Moulin, V.
    Boudou, C.
    Verger, L.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (01) : 408 - 415
  • [5] Progress in development on CdZnTe x-ray detector
    Zhou, Yongdong
    Zhou, Ning
    Zhang, Linhu
    Wang, Jin
    Wan, Aihua
    SEMICONDUCTOR PHOTODETECTORS III, 2006, 6119
  • [6] Temporal pulsed x-ray response of CdZnTe: In detector
    Guo, Rong-Rong
    Xu, Ya-Dong
    Zha, Gang-Qiang
    Wang, Tao
    Jie, Wan-Qi
    CHINESE PHYSICS B, 2018, 27 (12)
  • [7] Temporal pulsed x-ray response of CdZnTe:In detector
    郭榕榕
    徐亚东
    查钢强
    王涛
    介万奇
    Chinese Physics B, 2018, 27 (12) : 454 - 458
  • [8] CdZnTe x-ray detector for 30 similar to 100 keV energy
    Yoo, SS
    Rodricks, B
    Shastri, SD
    Montano, PA
    HARD X-RAY/GAMMA-RAY AND NEUTRON OPTICS, SENSORS, AND APPLICATIONS, 1996, 2859 : 50 - 56
  • [9] The X-ray Radiation Response of CdZnTe Crystal Nuclear Detector
    Dai, X. Y.
    Meng, H.
    Zhang, Y. L.
    Tao, J.
    Xu, R.
    Zhang, J. J.
    Huang, J.
    Wang, L.
    Tang, K.
    Min, J. H.
    Wang, L. J.
    PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY AND MANAGEMENT SCIENCE (ITMS 2015), 2015, 34 : 1296 - 1299
  • [10] CdZnTe detector array for a Scanning-Beam Digital-X-ray system
    Heanue, JA
    Pearson, DA
    Melen, RE
    MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 : 718 - 725