SAFIR-I: Design and Performance of a High-Rate Preclinical PET Insert for MRI

被引:3
作者
Bebie, Pascal [1 ]
Becker, Robert [1 ]
Commichau, Volker [1 ]
Debus, Jan [1 ]
Dissertori, Gunther [1 ]
Djambazov, Lubomir [1 ]
Eleftheriou, Afroditi [2 ]
Fischer, Jannis [1 ]
Fischer, Peter [3 ]
Ito, Mikiko [1 ,5 ]
Khateri, Parisa [1 ]
Lustermann, Werner [1 ]
Ritzer, Christian [1 ]
Ritzert, Michael [3 ]
Roser, Ulf [1 ]
Tsoumpas, Charalampos [4 ,6 ]
Warnock, Geoffrey [2 ,7 ]
Weber, Bruno [2 ]
Wyss, Matthias T. [2 ]
Zagozdzinska-Bochenek, Agnieszka [1 ]
机构
[1] Swiss Fed Inst Technol, Inst Particle Phys & Astrophys, CH-8093 Zurich, Switzerland
[2] Univ Zurich, Inst Pharmacol & Toxicol, CH-8057 Zurich, Switzerland
[3] Heidelberg Univ, Inst Comp Engn, D-69120 Heidelberg, Germany
[4] Univ Leeds, Leeds Inst Cardiovasc & Metab Med, Leeds LS2 9JT, W Yorkshire, England
[5] LG South Korea, Seoul 07336, South Korea
[6] Univ Groningen, Univ Med Ctr Groningen, Med Imaging Ctr, Dept Nucl Med & Mol Imaging, NL-9700 RB Groningen, Netherlands
[7] Univ Zurich, Ctr Mol Cardiol, CH-8952 Zurich, Switzerland
关键词
PET detector; PET insert; MRI; preclinical PET/MRI; dynamic PET/MR imaging; high frame rates; 5 s time frames; temporal resolution;
D O I
10.3390/s21217037
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
(1) Background: Small Animal Fast Insert for MRI detector I (SAFIR-I) is a preclinical Positron Emission Tomography (PET) insert for the Bruker BioSpec 70/30 Ultra Shield Refrigerated (USR) preclinical 7 T Magnetic Resonance Imaging (MRI) system. It is designed explicitly for high-rate kinetic studies in mice and rats with injected activities reaching 500 MBq, enabling truly simultaneous quantitative PET and Magnetic Resonance (MR) imaging with time frames of a few seconds in length. (2) Methods: SAFIR-I has an axial field of view of 54.2 mm and an inner diameter of 114 mm. It employs Lutetium Yttrium OxyorthoSilicate (LYSO) crystals and Multi Pixel Photon Counter (MPPC) arrays. The Position-Energy-Timing Application Specific Integrated Circuit, version 6, Single Ended (PETA6SE) digitizes the MPPC signals and provides time stamps and energy information. (3) Results: SAFIR-I is MR-compatible. The system's Coincidence Resolving Time (CRT) and energy resolution are between (209.0 +/- 0.3) ps and (12.41 +/- 0.02)% Full Width at Half Maximum (FWHM) at low activity and (326.89 +/- 0.12) ps and (20.630 +/- 0.011)% FWHM at 550 MBq, respectively. The peak sensitivity is similar to 1.6%. The excellent performance facilitated the successful execution of first in vivo rat studies beyond 300 MBq. Based on features visible in the acquired images, we estimate the spatial resolution to be mm similar to 2 in the center of the Field Of View (FOV). (4) Conclusion: The SAFIR-I PET insert provides excellent performance, permitting simultaneous in vivo small animal PET/MR image acquisitions with time frames of a few seconds in length at activities of up to 500 MBq.
引用
收藏
页数:27
相关论文
共 48 条
[1]   Advances in Preclinical PET Instrumentation [J].
Amirrashedi, Mahsa ;
Zaidi, Habib ;
Ay, Mohammad Reza .
PET CLINICS, 2020, 15 (04) :403-426
[2]  
[Anonymous], 2008, Performance measurements of small-animal positron emission tomographs
[3]   First Human Imaging Studies with the EXPLORER Total-Body PET Scanner [J].
Badawi, Ramsey D. ;
Shi, Hongcheng ;
Hu, Pengcheng ;
Chen, Shuguang ;
Xu, Tianyi ;
Price, Patricia M. ;
Ding, Yu ;
Spencer, Benjamin A. ;
Nardo, Lorenzo ;
Liu, Weiping ;
Bao, Jun ;
Jones, Terry ;
Li, Hongdi ;
Cherry, Simon R. .
JOURNAL OF NUCLEAR MEDICINE, 2019, 60 (03) :299-303
[4]   Performance Evaluation of the Inveon Dedicated PET Preclinical Tomograph Based on the NEMA NU-4 Standards [J].
Bao, Qinan ;
Newport, Danny ;
Chen, Mu ;
Stout, David B. ;
Chatziioannou, Arion F. .
JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (03) :401-408
[5]   The SAFIR project: an innovative high rate preclinical PET/MR detector towards dynamic multimodal imaging [J].
Robert Becker ;
Chiara Casella ;
Gunther Dissertori ;
Jannis Fischer ;
Alexander Howard ;
Astrik Jeitler ;
Werner Lustermann ;
Ulf Roeser ;
Qiulin Wang ;
Bruno Weber .
EJNMMI Physics, 2 (Suppl 1)
[6]   Development and Evaluation of mini-EXPLORER: A Long Axial Field-of-View PET Scanner for Nonhuman Primate Imaging [J].
Berg, Eric ;
Zhang, Xuezhu ;
Bec, Julien ;
Judenhofer, Martin S. ;
Patel, Brijesh ;
Peng, Qiyu ;
Kapusta, Maciej ;
Schmand, Matthias ;
Casey, Michael E. ;
Tarantal, Alice F. ;
Qi, Jinyi ;
Badawi, Ramsey D. ;
Cherry, Simon R. .
JOURNAL OF NUCLEAR MEDICINE, 2018, 59 (06) :993-998
[7]  
Bruker, TRUE TRIM PRECL PET
[8]  
Catana C, 2006, J NUCL MED, V47, P1968
[9]  
Conti M, 2005, P IEEE NUCL SCI S C, V3, P6
[10]   The new opportunities for high time resolution clinical TOF PET [J].
Conti, Maurizio ;
Bendriem, Bernard .
CLINICAL AND TRANSLATIONAL IMAGING, 2019, 7 (02) :139-147