Twin machines validation for VMAT treatments using electronic portal-imaging device: a multicenter study

被引:2
|
作者
Fenoglietto, P. [1 ]
Khodri, M. [2 ]
Nguyen, D. [3 ]
Josserand-Pietri, F. [4 ]
Ailleres, N. [1 ]
机构
[1] Inst Reg Canc Montpellier ICM, Dept Oncol Radiotherapie, F-34298 Montpellier 5, France
[2] ICL, Dept Oncol Radiotherapie, St Etienne, France
[3] Grp ORLAM, Serv Radiotherapie, Macon, France
[4] Grp ORLAM, Serv Radiotherapie, Villeurbanne, France
关键词
VOLUMETRIC-MODULATED ARC; QUALITY-ASSURANCE; CLINICAL IMPLEMENTATION; PROSTATE-CANCER; DYNAMIC IMRT; RADIOTHERAPY; DELIVERY; THERAPY; RAPIDARC; VERIFICATION;
D O I
10.1186/s13014-015-0577-3
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To verify the accuracy of volumetric arc therapy (VMAT) using the RapidArc (TM) device when switching patients from one single linear accelerator (linac) to a paired energy and mechanics "twin" linac without reoptimization of the original treatment plan. Patients and Methods: Four centers using 8 linacs were involved in this study. Seventy-four patients previously treated with the 6MV photon RapidArc (TM) technique were selected for analysis, using 242 measurements. In each institution, all patients were planned on linac A, and their plans were verified both on linac A and on the twin linac B. Verifications were done using the amorphous silicium electronic portal imager (EPID) of the linacs and were analyzed with the EpiQa software (Epidos, Bratislavia, Slovakia). The gamma index formalism was used for validation with a double threshold of 3 % and 3 mm with a measurement resolution of 0.39 mm/pixel, and a smoothed resolution of approximately 2.5 mm. Results: The number of points passing the gamma criteria between the measured and computed doses was 94.79 +/- 2.57 % for linac A and 94.61 +/- 2.46 % for linac B. Concerning the smoothed measurement analysis, 98.67 +/- 1.26 % and 98.59 +/- 1.20 % points passing the threshold were obtained for linacs A and B, respectively. The difference between the 2 dose matrices acquired on the EPID was very small, with 99.92 +/- 0.06 % of the points passing the criteria. Conclusion: For linacs sharing the same mechanical and energy parameters, this study tends to indicate that patients may be safely switched from treatment with one linac to treatment with its twin linac using the same VMAT plan.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Accuracy of the dose delivery in prostate cancer patients-using an electronic portal imaging device (EPID)
    Mahdavi, S. R.
    Gharehbagh, E. Jazayeri
    Mofid, B.
    Jafari, A. H.
    Nikoofar, A. R.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2017, 15 (01): : 39 - 47
  • [22] Performance of a linear accelerator couch positioning quality control task using an electronic portal imaging device
    Afzalifar, A.
    Mowlavi, A. A.
    Mohammadi, M.
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2020, 13 (02) : 195 - 200
  • [23] Performance of a linear accelerator couch positioning quality control task using an electronic portal imaging device
    A. Afzalifar
    A. A. Mowlavi
    M. Mohammadi
    Radiological Physics and Technology, 2020, 13 : 195 - 200
  • [24] Verification of MLC based real-time tumor tracking using an electronic portal imaging device
    Han-Oh, Sarah
    Yi, Byong Yong
    Lerma, Fritz
    Berman, Barry L.
    Gui, Minzhi
    Yu, Cedric
    MEDICAL PHYSICS, 2010, 37 (06) : 2435 - 2440
  • [25] Verification of milled two-dimensional photon compensating filters using an electronic portal imaging device
    Low, DA
    Li, ZF
    Klein, EE
    MEDICAL PHYSICS, 1996, 23 (06) : 929 - 938
  • [26] The feasibility of the pretreatment verification of 2D dose distributions in radiation therapy with small fields using the electronic portal imaging device
    Tuncel, Nina
    Mahdavi, Seied Rabi
    Haghparast, Mohammad
    Karakus, Ismail
    Haghparast, Abbas
    Nazari, Vahideh
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2023, 19 : S815 - S820
  • [27] Optimisation of the imaging and dosimetric characteristics of an electronic portal imaging device employing plastic scintillating fibres using Monte Carlo simulations
    Blake, S. J.
    McNamara, A. L.
    Vial, P.
    Holloway, L.
    Kuncic, Z.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (22): : 6827 - 6840
  • [28] Tracking lung tumour motion using a dynamically weighted optical flow algorithm and electronic portal imaging device
    Teo, P. T.
    Crow, R.
    Van Nest, S.
    Sasaki, D.
    Pistorius, S.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2013, 24 (07)
  • [29] SIFT: A method to verify the IMRT fluence delivered during patient treatment using an electronic portal imaging device
    Vieira, SC
    Dirkx, MLP
    Heijmen, BJM
    de Boer, HCJ
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (03): : 981 - 993
  • [30] Deep learning-based 3D in vivo dose reconstruction with an electronic portal imaging device for magnetic resonance-linear accelerators: a proof of concept study
    Li, Yongbao
    Xiao, Fan
    Liu, Biaoshui
    Qi, Mengke
    Lu, Xingyu
    Cai, Jiajun
    Zhou, Linghong
    Song, Ting
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (23):