The value of highest quality ultrasound as a reference for ultrasound diagnosis

被引:77
作者
Heese, F. [1 ]
Goerg, C. [1 ]
机构
[1] Klinikum Philipps Univ, Innere Med Klin, Marburg, Germany
来源
ULTRASCHALL IN DER MEDIZIN | 2006年 / 27卷 / 03期
关键词
ultrasound; quality assurance; reference ultrasound;
D O I
10.1055/s-2006-926665
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Aim: The aim of this study is to determine whether an additional ultrasound examination of DEGUM grade 3 (DEGUM 3) requested by examiners of DEGUM grade 1, 2 (DEGUM 1, 2) results in a diagnostic improvement. Methods: From October 2000 till June 2003 our university internal medicine sonography unit examined 34980 patients. In 211 cases DEGUM grade 1, 2 examiners requested a second opinion by DEGUM grade 3 examiners. 28 subjects were excluded because of unconfirmed diagnosis. Data of 183 patients with assured diagnoses were retrospectively analysed. We compared DEGUM 1, 2 findings with DEGUM 3 results regarding the accuracy of the firmed diagnosis. Results: In 38.8% (71 out of 183 subjects) the correct diagnosis was ascertained by DEGUM 1, 2. DEGUM 3 confirmed the correct diagnosis in 94.5% (173 out of 183 subjects). DEGUM 3 changed 106 (57.9%) findings of DEGUM 1, 2 and approved 77 findings (42.1%). In total DEGUM 3 diagnosed incorrectly twice compared to DEGUM 1, 2. In comparison to the assured diagnosis DEGUM 3 diagnosed 10 subjects incorrectly. Conclusion: The reference ultrasound examination done by an examiner with DEGUM grade 3 significantly increases the diagnostic accuracy compared to the ultrasonic measurement done by DEGUM grade 1, 2 investigators.
引用
收藏
页码:220 / 224
页数:5
相关论文
共 11 条
[1]   An evaluation of the inter-observer and intra-observer variability of the ultrasound diagnosis of polycystic ovaries [J].
Amer, SAKS ;
Li, TC ;
Bygrave, C ;
Sprigg, A ;
Saravelos, H ;
Cooke, ID .
HUMAN REPRODUCTION, 2002, 17 (06) :1616-1622
[2]   Sonography of solid breast lesions: Observer variability of lesion description and assessment [J].
Baker, JA ;
Kornguth, PJ ;
Soo, MS ;
Walsh, R ;
Mengoni, P .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (06) :1621-1625
[3]   Quality control of sonography courses in advanced training of physicians:: Analysis of present status and potential for improvement [J].
Hofer, M ;
Mey, N ;
Metten, J ;
Hartwig, HG ;
Mödder, U .
ULTRASCHALL IN DER MEDIZIN, 2002, 23 (03) :189-197
[4]   Research in abdominal ultrasound in university hospital departments of gastroenterology: The situation in Germany [J].
Kratzer, W ;
Pfeiffer, M ;
Gebel, M ;
Dietrich, C ;
Adler, G .
ZEITSCHRIFT FUR GASTROENTEROLOGIE, 2000, 38 (10) :833-+
[5]  
KRUG B, 2003, ROFO FORTSCHR RONTG, V1, P175
[6]  
KRUG B, 2003, ROFO FORTSCHR RONTG, V3, P346
[7]   QUALIFICATION AND QUALITY-CONTROL IN SONOGRAPHY [J].
LOCH, EG ;
BONHOF, J ;
BOTTCHER, D ;
HAUSEN, W ;
HAMMES, P ;
LINHART, P ;
NAUTH, P ;
PFANNENSTIEL, P ;
SCHMARSOW, R ;
UTECH, C .
ULTRASCHALL IN DER MEDIZIN, 1985, 6 (05) :250-254
[8]   Transrectal ultrasonography in male subfertility patients: an intra- and interobserver study [J].
Schipper, RA ;
Trum, JW ;
Messelink, EJ ;
van der Veen, F ;
Kurth, KH .
UROLOGICAL RESEARCH, 2001, 29 (01) :57-59
[9]   Interobserver variability of magnetic resonance angiography in the diagnosis of carotid stenosis - effect of observer experience [J].
Wardlaw, JM ;
Lewis, SC ;
Collie, DA ;
Sellar, R .
NEURORADIOLOGY, 2002, 44 (02) :126-132
[10]  
2002, 3 STUFENKONZEPT SONO