Radiation exposure from chest CT: Issues and strategies

被引:45
作者
Kalra, MK
Maher, MM
Rizzo, S
Kanarek, D
Shephard, JAO
机构
[1] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
[2] Massachusetts Gen Hosp, Dept Pulm & Crit Care Med, Boston, MA 02114 USA
[3] Harvard Univ, Sch Med, Boston, MA USA
关键词
tomography x-ray computed; CT chest; radiation dosage;
D O I
10.3346/jkms.2004.19.2.159
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Concerns have been raised over alleged overuse of CT scanning and inappropriate selection of scanning methods, all of which expose patients to unnecessary radiation. Thus, it is important to identify clinical situations in which techniques with lower radiation dose such as plain radiography or no radiation such as MRI and occasionally ultrasonography can be chosen over CT scanning. This article proposes the arguments for radiation dose reduction in CT scanning of the chest and discusses recommended practices and studies that address means of reducing radiation exposure associated with CT scanning of the chest.
引用
收藏
页码:159 / 166
页数:8
相关论文
共 72 条
[1]   FEASIBILITY OF HIGH-RESOLUTION, LOW-DOSE CHEST CT IN EVALUATING THE PEDIATRIC CHEST [J].
AMBROSINO, MM ;
GENIESER, NB ;
ROCHE, KJ ;
KAUL, A ;
LAWRENCE, RM .
PEDIATRIC RADIOLOGY, 1994, 24 (01) :6-10
[2]  
[Anonymous], 2000, Health Phys, V79, P314
[3]  
Catalano MF, 2002, AM J GASTROENTEROL, V97, P2559
[4]  
Commission of the European Community, 1999, 16262 EUR EN COMM EU
[5]   Pulmonary nodules: Experimental and clinical studies at low-dose CT [J].
Diederich, S ;
Lenzen, H ;
Windmann, R ;
Puskas, Z ;
Yelbuz, TM ;
Henneken, S ;
Klaiber, T ;
Eameri, M ;
Roos, N ;
Peters, PE .
RADIOLOGY, 1999, 213 (01) :289-298
[6]   Low-dose computed tomography of the thorax. Experimental and clinical investigations [J].
Diederich, S ;
Lenzen, H ;
Puskas, Z ;
Koch, AT ;
Yelbuz, TM ;
Eameri, M ;
Roos, N ;
Peters, PE .
RADIOLOGE, 1996, 36 (06) :475-482
[7]   Low-dose CT: new tool for screening lung cancer? [J].
Diederich, S ;
Wormanns, D ;
Heindel, W .
EUROPEAN RADIOLOGY, 2001, 11 (10) :1916-1924
[8]  
Diederich S, 2000, CANCER, V89, P2457, DOI 10.1002/1097-0142(20001201)89:11+<2457::AID-CNCR22>3.3.CO
[9]  
2-Z
[10]   Minimizing radiation dose for pediatric body applications of single-detector helical CT: Strategies at a large children's hospital [J].
Donnelly, LF ;
Emery, KH ;
Brody, AS ;
Laor, T ;
Gylys-Morin, VM ;
Anton, CG ;
Thomas, SR ;
Frush, DP .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) :303-306