Nitric acid effect in inductively coupled plasma mass spectrometry: new insights on possible causes and correction

被引:12
作者
Grotti, Marco [1 ]
Todoli, Jose-Luis [2 ]
机构
[1] Univ Genoa, Dept Chem & Ind Chem, Via Dodecaneso 31, I-16146 Genoa, Italy
[2] Dept Analyt Chem Nutr & Food Sci, POB 99, Alicante 03080, Spain
关键词
ATOMIC EMISSION-SPECTROMETRY; INTERNAL STANDARDS; INTERFERENCES; SELECTION;
D O I
10.1039/d0ja00130a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Fundamental aspects related to the analysis of nitric acid solutions by inductively coupled plasma mass spectrometry have been critically revisited in order to provide new insights into the possible sources of non-spectroscopic matrix effects and their correction by internal standardization. For elements having first ionization potential (IP) lower than 7.5 eV, the increase in the signal due to nitric acid was ascribed to a delay in the ionization process, which resulted in a reduction of the ion lateral diffusion in the plasma. In contrast, for non-easily ionisable elements, signal depression was correlated with their IP value and attributed to the cooling effect due to the energy required for nitric acid dissociation. Moreover, the atomic mass did not show any significant effect, thus precluding the application of the widely accepted criterion of choice of internal standards based on matching of masses. The extent and sign of the acid effect also depended on the applied operating conditions. For elements with low IP (e.g.Co, Cs, In, Li, Pb, Y), nitric acid caused signal enhancement at high RF power and nebulizer gas flow rate values (i.e., plasma robust conditions) and signal depression under non-robust conditions. For elements with high IP (e.g.As, Be, Cd and Sb), the decreasing acid effect became stronger with increasing the nebulizer gas flow rate and decreasing the RF power. The acid effect was also influenced by the ion lens voltage, that significantly interacted with the RF power effect. Finally, a procedure for the selection of optimal internal standards by principal component analysis has been successfully applied for the correction of the nitric acid effect.
引用
收藏
页码:1959 / 1968
页数:10
相关论文
共 25 条
[1]   Matrix effects in inductively coupled plasma mass spectrometry: A review [J].
Agatemor, Christian ;
Beauchemin, Diane .
ANALYTICA CHIMICA ACTA, 2011, 706 (01) :66-83
[2]  
Box George E.P., 1978, Statistics for experimenters, V664
[3]   FUNDAMENTAL-STUDIES ON PNEUMATIC GENERATION AND AEROSOL TRANSPORT IN ATOMIC SPECTROMETRY - EFFECT OF MINERAL ACIDS ON EMISSION INTENSITY IN INDUCTIVELY-COUPLED PLASMA-ATOMIC EMISSION-SPECTROMETRY [J].
CANALS, A ;
HERNANDIS, V ;
TODOLI, JL ;
BROWNER, RF .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1995, 50 (4-7) :305-321
[4]   INTERFERENCES IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY - A REVIEW [J].
EVANS, EH ;
GIGLIO, JJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (01) :1-18
[5]   Choosing internal standards based on a multivariate analysis approach with ICP(TOF)MS [J].
Finley-Jones, Haley J. ;
Molloy, John L. ;
Holcombe, James A. .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2008, 23 (09) :1214-1222
[6]   NEON AND ARGON BONDING IN 1ST-ROW CATIONS NEX+ AND ARX+ (X=LI-NE) [J].
FRENKING, G ;
KOCH, W ;
CREMER, D ;
GAUSS, J ;
LIEBMAN, JF .
JOURNAL OF PHYSICAL CHEMISTRY, 1989, 93 (09) :3410-3418
[7]   Combined effects of inorganic acids in inductively coupled plasma optical emission spectrometry [J].
Grotti, M ;
Leardi, R ;
Frache, R .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2002, 57 (12) :1915-1924
[8]   Reduction of acid effects in inductively coupled plasma optical emission spectrometry using internal standards selected by principal component analysis [J].
Grotti, M ;
Frache, R .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (10) :1192-1197
[9]   Selection of internal standards in inductively coupled plasma atomic emission spectrometry by principal component analysis [J].
Grotti, M ;
Magi, E ;
Leardi, R .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (03) :274-281
[10]   Building and analyzing models from data by stirred tank experiments for investigation of matrix effects caused by inorganic matrices and selection of internal standards in Inductively Coupled Plasma-Atomic Emission Spectroscopy [J].
Grotti, Marco ;
Paredes, Eduardo ;
Maestre, Salvador ;
Todoli, Jose Luis .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2008, 63 (05) :571-584