Purification and growth of PbI2 crystals -: Dependence of the radiation response on the PbI2 crystal purity

被引:0
作者
Oliveira, IB [1 ]
Costa, FE [1 ]
Armelin, MJ [1 ]
Cardoso, LP [1 ]
Hamada, MM [1 ]
机构
[1] IPEN CNEN SP, Sao Paulo, Brazil
来源
2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4 | 2002年
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This article describes the methodology for the purification of the PbI2 salt by technique of multipass zone refining and the growth by Bridgman method. A significant decrease of the impurities concentration was observed in function of the purification passes number. The results of the dark leakage current, the resistivity and the response of the alpha and gamma radiations were strongly dependent of the purity of the crystal.
引用
收藏
页码:2330 / 2334
页数:5
相关论文
共 19 条
  • [1] Improved performance lead iodide nuclear radiation detectors
    Deich, V
    Roth, M
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 380 (1-2) : 169 - 172
  • [2] Lead iodide film deposition and characterization
    Fornaro, L
    Saucedo, E
    Mussio, L
    Yerman, L
    Ma, X
    Burger, A
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 458 (1-2) : 406 - 412
  • [3] GLASCOCK MD, 2001, OVERVIEW NEUTRON ACT
  • [4] Lead iodide x-ray and gamma-ray spectrometers for room and high temperature operation
    Hermon, H
    James, RB
    Lund, J
    Cross, E
    Antolak, A
    Morse, DH
    Medlin, DL
    Soria, E
    Van Scyoc, J
    Brunett, B
    Schieber, M
    Schlesinger, TE
    Toney, J
    Goorsky, M
    Yoon, H
    Burger, A
    Salary, L
    Chen, KT
    Chang, YC
    Shah, K
    [J]. SEMICONDUCTORS FOR ROOM-TEMPERATURE RADIATION DETECTOR APPLICATIONS II, 1997, 487 : 361 - 368
  • [5] PROPERTIES OF LEAD IODIDE SEMICONDUCTOR RADIATION DETECTORS
    LUND, JC
    SHAH, KS
    SQUILLANTE, MR
    MOY, LP
    SINCLAIR, F
    ENTINE, G
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 283 (02) : 299 - 302
  • [6] RECENT PROGRESS IN LEAD IODIDE X-RAY SPECTROMETER DEVELOPMENT
    LUND, JC
    SHAH, KS
    OLSCHNER, F
    ZHANG, J
    MOY, L
    MEDRICK, S
    SQUILLANTE, MR
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 322 (03) : 464 - 466
  • [7] LUND JC, 1995, SEMICONDUCTORS ROOM, V43
  • [8] PBI2 AS NUCLEAR-PARTICLE DETECTOR
    MANFREDOTTI, C
    MURRI, R
    QUIRINI, A
    VASANELLI, L
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1977, 24 (01) : 126 - 128
  • [9] Room-temperature compound semiconductor radiation detectors
    McGregor, DS
    Hermon, H
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 395 (01) : 101 - 124
  • [10] Characterization of lead iodide for nuclear spectrometers
    Schlesinger, TE
    James, RB
    Schieber, M
    Toney, J
    VanScyoc, JM
    Salary, L
    Hermon, H
    Lund, J
    Burger, A
    Chen, KT
    Cross, E
    Soria, E
    Shah, K
    Squillante, M
    Yoon, H
    Goorsky, M
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 380 (1-2) : 193 - 197