Optimizing fixation methods for stable and unstable intertrochanteric hip fractures treated with sliding hip screw or cephalomedullary nailing: A comparative biomechanical and finite element analysis study

被引:9
|
作者
Kyriakopoulos, G. [1 ,7 ]
Panagopoulos, A. [2 ]
Pasiou, E. [3 ]
Kourkoulis, S. K. [3 ]
Diamantakos, I. [4 ]
Anastopoulos, G. [1 ]
Tserpes, K. [5 ]
Tatani, I. [2 ]
Lakoumentas, J. [6 ]
Megas, P. [2 ]
机构
[1] Georgios Gennimatas Gen Hosp, Dept Orthopaed, Athens, Greece
[2] Patras Univ Hosp, Dept Adult Reconstruct, Orthopaed Clin, Patras, Greece
[3] NTUA, Sch Appl Math & Phys Sci, Dept Mech, Lab Biomech & Biomed Phys, Athens, Greece
[4] Univ Peloponnese, Sch Engn, Dept Mech Engn, Patras, Greece
[5] Univ Patras, Dept Mech Engn & Aeronaut, Lab Technol & Strength Mat, Patras, Greece
[6] Univ Patras, Sch Med, Dept Med Phys, Patras, Greece
[7] Peripheral Gen Hosp Athens Giorgos Gennimatas, Orthopaed Dept 1, Athens, Greece
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2022年 / 53卷 / 12期
关键词
Intertrochanteric fractures; Pertrochanteric; Fractures; Hip fractures; Dynamic hip screw; DHS; Cephalomedullary nailing; Gamma3; Biomechanical testing; Finite element analysis; Cut-out; Mechanical failure; Implant angle; TAD; Tip-to-apex distance; Varus reduction; Valgus reduction; TIP-APEX DISTANCE; PROXIMAL FEMORAL NAIL; TROCHANTERIC FRACTURES; LAG SCREW; RISK-FACTORS; GAMMA-NAIL; FAILURE; CUTOUT; INTRAMEDULLARY; FEMUR;
D O I
10.1016/j.injury.2022.10.006
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Despite recent advances in implants and surgical techniques, catastrophic and clinical fail-ures in the treatment of intertrochanteric fractures continue to occur, with dire consequences in an over-all frail population subset. The aim of the current study is to evaluate the effect of the factors under the surgeons' control, namely fracture reduction and implant selection, on the biomechanical behavior of fracture fixation constructs.Material-Methods: An experimental protocol was conducted with the use of instrumented sawbones, in order to validate the finite element models. The implants used were the Gamma3 (R) and DHS systems. Subsequently, a series of scenaria were considered, including various reduction and implant angle combi-nations. Data were retrieved concerning the peak cancellous bone stresses around the hip screw and the volume of cancellous bone in the femoral head stressed at critical levels, as well as implant stresses and stresses on the cortical bone of the distal fragment.Results: All stable fracture models displayed significantly decreased cancellous bone stresses and implant stresses compared to their unstable counterparts, regardless of implant used. The effect of increasing im-plant angle led to a decrease in implant stresses in all models studied, but had a beneficial effect on the stresses in the cancellous bone of the proximal fragment only in the subgroups of stable fractures with both implants and unstable fractures treated with a cephalomedullary nail (CMN). In unstable fractures anatomically reduced, the use of CMN led to significantly lower peak stresses in the cancellous bone and a smaller volume of bone stressed at critical levels. Increasing the reduction angle by 5 degrees led to a signifi-cant decrease in both peak stresses and volume of bone stressed at critical levels, more prominent in the sliding hip screw (SHS) models. Decreasing the reduction angle into varus by 5 or 10 degrees led to a significant increase in bone and implant stresses regardless of implant used.Conclusions: In stable two-part (AO31.A2) fractures the use of the SHS appears to be biomechanically equivalent to CMN. In unstable, anatomically reduced fractures, the use of CMN leads to significantly reduced cancellous bone stresses and decreased rotation of the proximal fragment during loading.A reduction in varus should be avoided at all costs. In unstable fractures treated with SHS a reduction in slight valgus appears to be biomechanically beneficial. The highest implant angle that allows for proper screw position and trajectory in the femoral head should be used for stable fractures with both implants and unstable fractures treated with Gamma3 (R).(c) 2022 Elsevier Ltd. All rights reserved.
引用
收藏
页码:4072 / 4085
页数:14
相关论文
共 45 条
  • [21] Traditional and bionic dynamic hip screw fixation for the treatment of intertrochanteric fracture: a finite element analysis
    Cun, Yunwei
    Dou, Chenhou
    Tian, Siyu
    Li, Ming
    Zhu, Yanbin
    Cheng, Xiaodong
    Chen, Wei
    INTERNATIONAL ORTHOPAEDICS, 2020, 44 (03) : 551 - 559
  • [22] The importance of lag screw position for the stabilization of trochanteric fractures with a sliding hip screw: A subject-specific finite element study
    Goffin, Jerome M.
    Pankaj, Pankaj
    Simpson, A. Hamish
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2013, 31 (04) : 596 - 600
  • [23] A Comparative Study of Functional Outcome Following Dynamic Hip Screw and Proximal Femoral Nailing for Intertrochanteric Fractures of the Femur
    Prakash, Anil Kumar
    Nagakumar, J. S.
    Shanthappa, Arun H.
    Venkataraman, Sagar
    Kamath, Amith
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (04)
  • [24] A Comparative Biomechanical Analysis of Fixation Devices for Unstable Femoral Neck Fractures: The Intertan Versus Cannulated Screws or a Dynamic Hip Screw
    Rupprecht, Martin
    Grossterlinden, Lars
    Ruecker, Andreas H.
    de Oliveira, Alexander Novo
    Sellenschloh, Kay
    Nuechtern, Jakob
    Pueschel, Klaus
    Morlock, Michael
    Rueger, Johannes Maria
    Lehmann, Wolfgang
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2011, 71 (03): : 625 - 634
  • [25] A COMPARATIVE STUDY OF RECONSTRUCTION NAILING VERSUS DYNAMIC HIP SCREW DEVICE IN THE SURGICAL MANAGEMENT OF INTERTROCHANTERIC FRACTURES
    Reddy, Pereddy Somashekhara
    Ponugoti, Nikhil
    Jampana, Venkata S.
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2016, 5 (99): : 7224 - 7230
  • [26] Dual lag screw cephalomedullary nail versus the classic sliding hip screw for the stabilization of intertrochanteric fractures. A prospective randomized study
    Kouvidis, G.
    Sakellariou, V. I.
    Mavrogenis, A. F.
    Stavrakakis, J.
    Kampas, D.
    Galanakis, J.
    Papagelopoulos, P. J.
    Katonis, P.
    STRATEGIES IN TRAUMA AND LIMB RECONSTRUCTION, 2012, 7 (03): : 155 - 162
  • [27] BIOMECHANICAL EFFECT OF DIFFERENT LAG SCREW LENGTHS WITH DIFFERENT BARREL LENGTHS IN DYNAMIC HIP SCREW SYSTEM: A FINITE ELEMENT ANALYSIS STUDY
    Tzeng, Chung-Yuh
    Huang, Kui-Chuo
    Wu, Yun-Che
    Chang, Chu-Ling
    Lee, Kuan-Rong
    Su, Kuo-Chih
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2017, 17 (01)
  • [28] Optimizing Screw Fixation in Total Hip Arthroplasty: A Deep Learning and Finite Element Analysis Approach
    Stroud, Jacob
    Yan, Emily T.
    Anthony, Jacob
    Walker, Kyle
    Goh, Chung-Hyun
    APPLIED SCIENCES-BASEL, 2025, 15 (07):
  • [29] Cephalomedullary nailing versus sliding hip screws for Intertrochanteric and basicervical hip fractures: a propensity-matched study of short-term outcomes in over 17,000 patients
    Warren, Jared A.
    Sundaram, Kavin
    Hampton, Robert
    McLaughlin, John
    Patterson, Brendan
    Higuera, Carlos A.
    Piuzzi, Nicolas S.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2020, 30 (02) : 243 - 250
  • [30] Comparative biomechanical evaluation of fixation methods in posterior pilon fractures: a finite element analysis
    Zhang, Yong-Tao
    Liu, Song
    Fu, Su
    Wu, Jian-Qun
    Yu, Bin
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2020, 13 (01): : 16 - 27