Development and testing of a low-cost condensation detection system

被引:0
作者
Montross, M. D. [1 ]
Duncan, G. A. [1 ]
Gates, R. S. [1 ]
机构
[1] Univ Kentucky, Biosyst & Agr Engn Dept, Lexington, KY 40546 USA
关键词
greenhouse; grain bin; moisture; ventilation; dehumidification; humidity control;
D O I
暂无
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
A condensation sensing and control system was designed to detect condensation using a commercially available leaf wetness sensor (LWS). The leaf wetness sensor was a variable resistance grid-type that responded to moisture on the surface. A circuit was developed to compare the LWS voltage output to a user specified reference voltage, and operate a relay for possible switching of a humidity control device (for example a fan and/or heater). The condensation detection system operation was validated in an environmental chamber in the laboratory using a heat exchanger and water bath. Condensate was immediately detected when the plate was cooled below the dew point temperature of the chamber When the water temperature increased above the dew point temperature, there was a delay as the moisture evaporated from the plate. Soil and other foreign material were added to the leaf wetness sensor with little effect on system performance. The soil acted to further delay the sensor from drying and predicted slightly longer condensation and recovery periods. The condensation detection system was tested in a transplant growing greenhouse and a grain bin, with operation verified by simultaneously measuring the relative humidity and dry bulb temperature. There were frequent periods of condensation in the greenhouse and the system accurately predicted them. Condensation did not occur in the grain bin, as was verified using the relative humidity and dry bulb temperature. The condensation detection system can provide a low-cost, rugged method for determining periods of condensation without the need for routine maintenance and calibration.
引用
收藏
页码:603 / 608
页数:6
相关论文
共 11 条
[1]  
ALDRICH RA, 1994, NE REGIONAL AGR ENG
[2]  
BOTTCHER RW, 1999, 994223 ASAE
[3]  
BURTON W, 1991, POTATO CROP, P608
[4]  
GATES RS, 1996, AEU90 U KENT BIOS AG
[5]  
HELLICKSON M. A., 1983, VENTILATION AGR STRU
[6]  
Montross MD, 2002, T ASAE, V45, P1455
[7]  
MULTON JL, 1980, CEREAL FOOD WORLD, V25, P16
[8]   PREVENTION OF CONDENSATION DAMAGE TO GROUNDNUTS IN CONTAINERS USING CALCIUM-CHLORIDE [J].
NAVARRO, S ;
PASTER, N ;
CARMI, Y .
CROP PROTECTION, 1988, 7 (03) :198-201
[9]  
TANAKA H, 1984, ENG FOOD, V1
[10]  