Preliminary Study of a Low-Cost Point-of-Care Testing System Using Screen-Printed Biosensors for Early Biomarkers Detection Related to Alzheimer Disease

被引:0
作者
Tonello, Sarah [1 ]
Serpelloni, Mauro [1 ]
Lopomo, Nicola Francesco [1 ]
Abate, Giulia [2 ]
Uberti, Daniela Letizia [2 ]
Sardini, Emilio [1 ]
机构
[1] Univ Brescia, Dept Informat Engn, Via Branze 38, I-25123 Brescia, Italy
[2] Univ Brescia, Dept Mol & Translat Med, Via Branze 38, I-25123 Brescia, Italy
来源
SENSORS | 2018年 / 431卷
关键词
Screen printing; Electrochemical biosensors; Voltammetry; Point-of-care testing; GOLD NANOPARTICLES; PROTEIN-DETECTION; SENSOR; IMMUNOSENSOR; MARKER; P53;
D O I
10.1007/978-3-319-55077-0_32
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Among neurodegenerative diseases, Alzheimer Disease (AD) represents one of the most widespread pathologies, for which an early diagnosis is still missing. A peculiar expression of an altered conformational isoform of p53 protein was reported to be a potential biomarker able to distinguish AD subjects from healthy population, quantifiable using a blood-based enzyme-linked immunosorbent assay (ELISA). In order to overcome ELISA limitations, related to reliability and to improve sensitivity, this study aimed to realize a low cost highly sensitive portable point-of-care (PoC) testing system based on screen printed electrochemical sensors (SPES). The development of the platform specifically included both the design of the sensing probe and of the electronic circuit devoted to the conditioning and acquisition of the transduced electric signal. Preliminary testing of the circuit were performed recording changes in the conductivity of NaCl solution and quantifying electrodes coating with antibodies using Electrochemical Impedance Spectroscopy (EIS) principle. Results obtained with saline solution, showed the ability of the circuit to give the best response corresponding to low changes in NaCl concentration (sensitivity 0.2 mA/(mg/ml)), suggesting a good sensitivity of the platform. Findings obtained from EIS showed the ability of the circuit to discriminate between different concentrations of antibodies coatings (sensitivity 80 mu A/mu g). Preliminary calibration of the sensor using interleukin IL-8 showed an increase in the maximum peak of current proportional to the increase of protein concentration, achieving a sensitivity of 35 mu A/ng and reporting also a good value of reproducibility, really promising in the perspective of lower values of proteins concentrations.
引用
收藏
页码:238 / 246
页数:9
相关论文
共 18 条
  • [1] Conformational Altered p53 as an Early Marker of Oxidative Stress in Alzheimer's Disease
    Buizza, Laura
    Cenini, Giovanna
    Lanni, Cristina
    Ferrari-Toninelli, Giulia
    Prandelli, Chiara
    Govoni, Stefano
    Buoso, Erica
    Racchi, Marco
    Barcikowska, Maria
    Styczynska, Maria
    Szybinska, Aleksandra
    Butterfield, David Allan
    Memo, Maurizio
    Uberti, Daniela
    [J]. PLOS ONE, 2012, 7 (01):
  • [2] Recent developments, characteristics and potential applications of screen-printed electrodes in pharmaceutical and biological analysis
    Couto, R. A. S.
    Lima, J. L. F. C.
    Quinaz, M. B.
    [J]. TALANTA, 2016, 146 : 801 - 814
  • [3] Current and Future Challenges in Point-of-Care Technologies: A Paradigm-Shift in Affordable Global Healthcare With Personalized and Preventive Medicine
    Dhawan, Atam P.
    Heetderks, William J.
    Pavel, Misha
    Acharya, Soumyadipta
    Akay, Metin
    Mairal, Anurag
    Wheeler, Bruce
    Dacso, Clifford C.
    Sunder, T.
    Lovell, Nigel
    Gerber, Martin
    Shah, Milind
    Senthilvel, S. G.
    Wang, May D.
    Bhargava, Balram
    [J]. IEEE JOURNAL OF TRANSLATIONAL ENGINEERING IN HEALTH AND MEDICINE, 2015, 3
  • [4] Electrochemical impedance immunosensor based on gold nanoparticles-protein G for the detection of cancer marker epidermal growth factor receptor in human plasma and brain tissue
    Elshafey, Reda
    Tavares, Ana C.
    Siaj, Mohamed
    Zourob, Mohammed
    [J]. BIOSENSORS & BIOELECTRONICS, 2013, 50 : 143 - 149
  • [5] Simultaneous detection of free and total prostate specific antigen on a screen-printed electrochemical dual sensor
    Escamilla-Gomez, Vanessa
    Hernandez-Santos, David
    Begona Gonzalez-Garcia, Maria
    Manuel Pingarron-Carrazon, Jose
    Costa-Garcia, Agustin
    [J]. BIOSENSORS & BIOELECTRONICS, 2009, 24 (08) : 2678 - 2683
  • [6] Feng SL, 2015, IEEE INT SYM MED MEA, P586, DOI 10.1109/MeMeA.2015.7145271
  • [7] Identifying and validating biomarkers for Alzheimer's disease
    Humpel, Christian
    [J]. TRENDS IN BIOTECHNOLOGY, 2011, 29 (01) : 26 - 32
  • [8] Increased Electrocatalyzed Performance through Dendrimer-Encapsulated Gold Nanoparticles and Carbon Nanotube-Assisted Multiple Bienzymatic Labels: Highly Sensitive Electrochemical Immunosensor for Protein Detection
    Jeong, Bongjin
    Akter, Rashida
    Han, Oc Hee
    Rhee, Choong Kyun
    Rahman, Md Aminur
    [J]. ANALYTICAL CHEMISTRY, 2013, 85 (03) : 1784 - 1791
  • [9] Aptamers based electrochemical biosensor for protein detection using carbon nanotubes platforms
    Kara, Pinar
    de la Escosura-Muniz, Alfredo
    Maltez-da Costa, Marisa
    Guix, Maria
    Ozsoz, Mehmet
    Merkoci, Arben
    [J]. BIOSENSORS & BIOELECTRONICS, 2010, 26 (04) : 1715 - 1718
  • [10] Conformationally altered p53: a novel Alzheimer's disease marker?
    Lanni, C.
    Racchi, M.
    Mazzini, G.
    Ranzenigo, A.
    Polotti, R.
    Sinforiani, E.
    Olivari, L.
    Barcikowska, M.
    Styczynska, M.
    Kuznicki, J.
    Szybinska, A.
    Govoni, S.
    Memo, M.
    Uberti, D.
    [J]. MOLECULAR PSYCHIATRY, 2008, 13 (06) : 641 - 647