Analysis of Crystals Leading to Joint Arthropathies by Raman Spectroscopy: Comparison with Compensated Polarized Imaging

被引:23
作者
Cheng, Xingguo [1 ]
Haggins, Donard G. [2 ]
York, Russel H. [3 ]
Yeni, Yener N. [4 ]
Akkus, Ozan [1 ]
机构
[1] Purdue Univ, Weldon Sch Biomed Engn, W Lafayette, IN 47907 USA
[2] Henry Ford Hosp, Dept Rheumatol, Taylor, MI 48180 USA
[3] Beale Inst, Lansing, MI 48917 USA
[4] Henry Ford Hosp, Dept Orthopaed & Rehabil, Ctr Bone & Joint, Detroit, MI 48202 USA
关键词
Synovial fluid; Gout; Raman spectroscopy; SYNOVIAL-FLUID ANALYSIS; DEPOSITION DISEASE; IDENTIFICATION; MICROSCOPY; LABORATORIES; DIAGNOSIS;
D O I
10.1366/000370209787944280
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The current study, assessed the feasibility of the application of Raman spectroscopy toward the diagnosis of gout and pseudogout. First, the lowest concentrations of monosodium urate monohydrate (MSUM) and calcium pyrophosphate dihydrate (CPPD) crystals detectable by Raman spectroscopy were investigated by Mixing known amounts of synthetic crystals with synovial fluid in the concentration range of 1 to 100 mu g/mL. Second. a digestion protocol was developed for clinical samples to improve crystal extraction. The ensuing centrifugation of the digest congregated crystals at a well-defined point and allowed for point-and-shoot Raman analysis without having to conduct an extensive search for individual crystals. Finally. synovial fluid samples obtained from patients (n = 35) were cross-analyzed by polarized light microscopy (PLM) and the Raman method to compare and contrast the diagnoses of the two methods. It was found that Raman spectroscopy call detect MSUM and CPPD crystals with good sensitivity and specificity at concentrations as low as 5 mu g/mL, and 2.5 mu g/mL, respectively using the current method. This detection limit of Raman analysis is lower than that reported for PLM. Raman and PLM diagnoses of clinical samples agreed in 32 out of 35 samples in the entire sample pool. However, the rate of disagreement between PLM-based and Raman-based diagnoses was noteworthy within the subset of diseased samples (3 out of 10). indicating that PLM has limitations and that the confirmation by a secondary method is essential for a reliable outcome. The proposed protocol of sample preparation in(] Raman analysis ascribes baseline feasibility to the diagnosis of gout and pseudogout by Raman spectroscopy, thus justifying further studies using a larger clinical sample set for obtaining sensitivity and specificity.
引用
收藏
页码:381 / 386
页数:6
相关论文
共 20 条
  • [1] Identification of crystals in synovial fluid
    Dieppe, P
    Swan, A
    [J]. ANNALS OF THE RHEUMATIC DISEASES, 1999, 58 (05) : 261 - 263
  • [2] EISENBERG JM, 1984, ARCH INTERN MED, V144, P715, DOI 10.1001/archinte.144.4.715
  • [3] FAM AG, 1992, J RHEUMATOL, V19, P780
  • [4] DETECTION OF CRYSTALS IN SYNOVIAL-FLUIDS BY LIGHT-MICROSCOPY - SENSITIVITY AND RELIABILITY
    GORDON, C
    SWAN, A
    DIEPPE, P
    [J]. ANNALS OF THE RHEUMATIC DISEASES, 1989, 48 (09) : 737 - 742
  • [5] VARIATION IN SYNOVIAL-FLUID ANALYSIS BY HOSPITAL LABORATORIES
    HASSELBACHER, P
    [J]. ARTHRITIS AND RHEUMATISM, 1987, 30 (06): : 637 - 642
  • [6] Hawi SR, 1997, J LIPID RES, V38, P1591
  • [7] CRYSTAL DEPOSITION DISEASE - DIAGNOSIS BY ELECTRON-MICROSCOPY
    HONIG, S
    GOREVIC, P
    HOFFSTEIN, S
    WEISSMANN, G
    [J]. AMERICAN JOURNAL OF MEDICINE, 1977, 63 (01) : 161 - 164
  • [8] RAMAN-SPECTROSCOPIC IDENTIFICATION OF URIC-ACID-TYPE KIDNEY-STONE
    KODATI, VR
    TU, AT
    TURUMIN, JL
    [J]. APPLIED SPECTROSCOPY, 1990, 44 (07) : 1134 - 1136
  • [9] CLINICAL UTILITY OF THE ALIZARIN RED-S STAIN ON PERMANENT PREPARATIONS TO DETECT CALCIUM-CONTAINING COMPOUNDS IN SYNOVIAL-FLUID
    LAZCANO, O
    LI, CY
    PIERRE, RV
    ODUFFY, JD
    BEISSNER, RS
    ABELLALEFF, PC
    [J]. AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1993, 99 (01) : 90 - 96
  • [10] MAUGARS YM, 1994, J RHEUMATOL, V21, P573