The water fouling development in plate heat exchangers with plates of different corrugations geometry

被引:13
作者
Arsenyeva, Olga [1 ]
Matsegora, Olexander [2 ]
Kapustenko, Petro [2 ]
Yuzbashyan, Anna [3 ]
Klemes, Jiri Jaromir [1 ]
机构
[1] Brno Univ Technol VUT Brno, Fac Mech Engn, NETME Ctr, Sustainable Proc Integrat Lab, Tech 2896-2, Brno 61669, Czech Republic
[2] Natl Tech Univ Kharkiv Polytech Inst, 2 Kyrpychova St, UA-61002 Kharkiv, Ukraine
[3] OM Beketov Natl Univ Urban Econ Kharkiv, Dept Automatic Control & Comp Integrated Engn, 17 Marshal Bazhanov St, UA-61002 Kharkiv, Ukraine
关键词
Plate heat exchangers; Fouling; Corrugation geometry; Optimal design;
D O I
10.1016/j.tsep.2022.101310
中图分类号
O414.1 [热力学];
学科分类号
摘要
The occurrence of fouling conditions in heat transfer equipment of industrial enterprises causes the change of process regimes and can lead to full blockage of heat transfer channels. The investigation of fouling dynamics in plate heat exchangers (PHEs) is observed. The transport and reaction type of fouling model is used for accounting for the fouling on the heat transfer surface. The mathematical model of PHEs with commercially produced plates is presented. The model accounts for the difference in pressure drop and heat transfer coefficients along with the heat carrier movement through the channel distinguishing the major corrugated field, the zones of flow distribution, ports and collector part, introducing the local hydraulic resistances for each zone. The PHE performance in fouling conditions for different plate corrugations geometry is analysed. The impact of the corrugations' inclination angle to the vertical plate's axis on fouling dynamics is analysed for the case when PHE is assembled with plates of non-uniform corrugations angles. The results of the case study, represented by modelling of PHE installed in a sugar factory for heating a thin juice coming to an evaporation station, are presented. The approach for fouling mitigation at PHE design through the optimisation of plate corrugation geometry is discussed. The economic analysis showed, that the purchase of additional plates for operating PHE allows for saving 220 kW of heat energy and ensures reliable operation during 120 d of the sugar campaign.
引用
收藏
页数:9
相关论文
共 32 条
[1]   Geochemical characterization of fouling on mine water driven plate heat exchangers in Saxon mining region, Germany [J].
Abeywickrama, Janith ;
Grimmer, Marlies ;
Hoth, Nils ;
Grab, Thomas ;
Drebenstedt, Carsten .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2021, 176
[2]   Investigation of scale deposits on Finchaa sugar factory ethanol plant heat transfer units [J].
Abo, Lata Deso ;
Hailegiorgis, Sintayehu Mekuria .
THERMAL SCIENCE AND ENGINEERING PROGRESS, 2021, 25
[3]   Fouling Detection in Industrial Heat Exchanger Using Number of Transfer Units Method, Neural Network, and Nonlinear Finite Impulse Response Models [J].
Andrijic, Zeljka Ujevic ;
Bolf, Nenad ;
Rimac, Nikola ;
Brzovic, Adriana .
HEAT TRANSFER ENGINEERING, 2022, 43 (21) :1852-1866
[4]   The Generalized Correlation for Friction Factor in Criss-cross Flow Channels of Plate Heat Exchangers [J].
Arsenyeva, Olga ;
Tovazhnyansky, Leonid ;
Kapustenko, Petro ;
Khavin, Gennady .
PRES 2011: 14TH INTERNATIONAL CONFERENCE ON PROCESS INTEGRATION, MODELLING AND OPTIMISATION FOR ENERGY SAVING AND POLLUTION REDUCTION, PTS 1 AND 2, 2011, 25 :399-+
[5]   Two types of welded plate heat exchangers for efficient heat recovery in industry [J].
Arsenyeva, Olga P. ;
Tovazhnyanskyy, Leonid L. ;
Kapustenko, Petro O. ;
Khavin, Genadii L. ;
Yuzbashyan, Anna P. ;
Arsenyev, Pavlo Yu. .
APPLIED THERMAL ENGINEERING, 2016, 105 :763-773
[6]   Accounting for the thermal resistance of cooling water fouling in plate heat exchangers [J].
Arsenyeva, Olga P. ;
Crittenden, Barry ;
Yang, Mangyan ;
Kapustenko, Petro O. .
APPLIED THERMAL ENGINEERING, 2013, 61 (01) :53-59
[7]   Molecular Understanding of Fouling Induction and Removal: Effect of the Interface Temperature on Milk Deposits [J].
Avila-Sierra, Alejandro ;
Huellemeier, Holly A. ;
Zhang, Zhenyu J. ;
Heldman, Dennis R. ;
Fryer, Peter J. .
ACS APPLIED MATERIALS & INTERFACES, 2021, 13 (30) :35506-35517
[8]   Analysis of 'classical' deposition rate law for crystallisation fouling [J].
Bansal, Bipan ;
Chen, Xiao Dong ;
Mueller-Steinhagen, Hans .
CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2008, 47 (08) :1201-1210
[9]   Application of artificial neural network (ANN-MLP) for the prediction of fouling resistance in heat exchanger to MgO-water and CuO-water nanofluids [J].
Benyekhlef, Ahmed ;
Mohammedi, Brahim ;
Hassani, Djamel ;
Hanini, Salah .
WATER SCIENCE AND TECHNOLOGY, 2021, 84 (03) :538-551
[10]   A Review of Crystallization Fouling in Heat Exchangers [J].
Berce, Jure ;
Zupancic, Matevz ;
Moze, Matic ;
Golobic, Iztok .
PROCESSES, 2021, 9 (08)