Estimation of thyroid gland volume by spiral computed tomography

被引:41
作者
Hermans, R
Bouillon, R
Laga, K
Delaere, PR
DeFoer, B
Marchal, G
Baert, AL
机构
[1] CATHOLIC UNIV LEUVEN,UNIV HOSP,DEPT ENDOCRINOL,B-3000 LOUVAIN,BELGIUM
[2] CATHOLIC UNIV LEUVEN,UNIV HOSP,DEPT OTOLARYNGOL HEAD & NECK SURG,B-3000 LOUVAIN,BELGIUM
关键词
CT; thyroid abnormalities; image processing;
D O I
10.1007/s003300050138
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The objective of this study was to test the accuracy of CT for the estimation of the volume of enlarged thyroid glands. An unenhanced spiral CT scan of neck and upper mediastinum was obtained in 36 patients with an enlarged thyroid gland. By manual segmentation the surface of the thyroid gland on 5-mm-thick slices was calculated; these surfaces were multiplied by the slice interval (10 mm) and summated to obtain the volume of the gland. All patients underwent a total or subtotal thyroidectomy. 1 cm(3) of thyroid gland tissue was considered to weigh 1 g. A good correlation was found between the volume estimated by CT and the weight at pathological examination of the resected gland (r = 0.98, p < 0.001), with a mean difference of + 12 % (range: + 57.3 to -13.9 %). The volume calculation is reproducible among different observers (r = 0.99, p < 0.01). Computed tomography allows an easy, reliable and reproducible volume determination of enlarged thyroid glands.
引用
收藏
页码:214 / 216
页数:3
相关论文
共 17 条
[1]   VOLUME DETERMINATIONS USING COMPUTED-TOMOGRAPHY [J].
BREIMAN, RS ;
BECK, JW ;
KOROBKIN, M ;
GLENNY, R ;
AKWARI, OE ;
HEASTON, DK ;
MOORE, AV ;
RAM, PC .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1982, 138 (02) :329-333
[2]   THYROID-GLAND VOLUME ESTIMATED BY USE OF ULTRASOUND IN ADDITION TO SCINTIGRAPHY [J].
BROWN, MC ;
SPENCER, R .
ACTA RADIOLOGICA ONCOLOGY, 1978, 17 (04) :337-341
[3]  
FRANKLYN JA, 1994, NEW ENGL J MED, V330, P1731
[4]  
HAKMAN ME, 1992, NUCL GENEESKD B, V14, P147
[5]   L-THYROXINE TREATMENT OF DIFFUSE NON-TOXIC GOITER EVALUATED BY ULTRASONIC DETERMINATION OF THYROID VOLUME [J].
HANSEN, JM ;
KAMPMANN, J ;
MADSEN, SN ;
SKOVSTED, L ;
SOLGAARD, S ;
GRYTTER, C ;
GRONTVEDT, T ;
RASMUSSEN, SN .
CLINICAL ENDOCRINOLOGY, 1979, 10 (01) :1-6
[6]  
HEGEDUS L, 1986, LANCET, V2, P339
[7]  
HEGEDUS L, 1990, DAN MED BULL, V37, P249
[8]   THE DETERMINATION OF THYROID VOLUME BY ULTRASOUND AND ITS RELATIONSHIP TO BODY-WEIGHT, AGE, AND SEX IN NORMAL SUBJECTS [J].
HEGEDUS, L ;
PERRILD, H ;
POULSEN, LR ;
ANDERSEN, JR ;
HOLM, B ;
SCHNOHR, P ;
JENSEN, G ;
HANSEN, JM .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 1983, 56 (02) :260-263
[9]  
HUYSMANS DAKC, 1993, EUR J NUCL MED, V20, P1056
[10]   LARGE, COMPRESSIVE GOITERS TREATED WITH RADIOIODINE [J].
HUYSMANS, DAKC ;
HERMUS, ARMM ;
CORSTENS, FHM ;
BARENTSZ, JO ;
KLOPPENBORG, PWC .
ANNALS OF INTERNAL MEDICINE, 1994, 121 (10) :757-762