Determination of tetraethyl ammonium by ion-pair chromatography with indirect ultraviolet detection using 4-aminophenol hydrochloride as background ultraviolet absorbing reagent

被引:20
|
作者
Zou, Chun-Miao
Yu, Hong [1 ]
Wang, Miao-Yu
机构
[1] Harbin Normal Univ, Coll Chem & Chem Engn, Harbin 150025, Peoples R China
关键词
Ion-pair chromatography; Indirect ultraviolet detection; Tetraethyl ammonium; 4-Aminophenol hydrochloride; INDIRECT UV DETECTION; CAPILLARY-ELECTROPHORESIS; LIQUID-CHROMATOGRAPHY; IMIDAZOLIUM; CATIONS; PHASE;
D O I
10.1016/j.cclet.2013.11.011
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A method was developed for the determination of tetraethyl ammonium (TEA) by reversed-phase ion-pair chromatography with indirect ultraviolet detection. Chromatographic separation was achieved on a reversed-phase C18 column using background ultraviolet absorbing reagent - ion-pair reagent - organic solvent as mobile phase. The effects of the background ultraviolet absorbing reagents, detection wavelength, ion-pair reagents, organic solvents and column temperature on the determination method were investigated and the retention rules discussed. Results found that TEA could be successfully analyzed by using 0.7 mmol/L 4-aminophenol hydrochloride and 0.15 mmol/L 1-heptanesulfonic acid sodium mixed with 20% (v/v) methanol as mobile phase at a UV detection wavelength of 230 nm. Under these conditions, the retention time of tetraethyl ammonium was 2.85 min. The detection limit (S/N = 3) for TEA was 0.06 mg/L. The relative standard deviations (n = 5) for peak area and retention time were 0.35% and 0.02%, respectively. The method has been successfully applied to the determination of synthesized tetraethyl ammonium bromide. Recovery of tetraethyl ammonium after spiking was 99.1%. (C) 2013 Hong Yu. Published by Elsevier B.V. on behalf of Chinese Chemical Society. All rights reserved.
引用
收藏
页码:201 / 204
页数:4
相关论文
共 23 条
  • [1] Determination of tetraethyl ammonium by ion-pair chromatography with indirect ultraviolet detection using 4-aminophenol hydrochloride as background ultraviolet absorbing reagent
    Chun-Miao Zou
    Hong Yu
    Miao-Yu Wang
    ChineseChemicalLetters, 2014, 25 (02) : 201 - 204
  • [2] Ion-pair chromatography-indirect ultraviolet detection for determination of tetraethyl ammonium using a monolithic column and a packed column
    Zou Chunmiao
    Zhang Xiaodong
    Yu Hong
    Guan Chao
    Wang Miaoyu
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2015, 33 (07) : 759 - 764
  • [3] Effect of ultraviolet absorption reagent for determination of piperidinium ionic liquid cations by ion pair chromatography with indirect ultraviolet detection
    Zhang, Xin-xin
    Yu, Hong
    Wang, Gang
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2017, 40 (13) : 671 - 676
  • [4] Determination of piperidinium ionic liquid cations by ion-pair chromatography-indirect ultraviolet detection
    Wang Miaoyu
    Yu Hong
    Li Ping
    Li Jie
    Gao Yufeng
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2014, 32 (07) : 773 - 778
  • [5] Monolithic Column Ion-Pair Chromatography with Indirect Ultraviolet Detection for the Determination of Three Acid Radical Anions Containing Fluorine in Ionic Liquids
    Liu, Sheng
    Jin, Xinxin
    Ma, Yajie
    Li, Hongxing
    Yu, Hong
    ANALYTICAL LETTERS, 2020, 53 (01) : 21 - 30
  • [6] Indirect ultraviolet detection of alkaline earth metal ions using an imidazolium ionic liquid as an ultraviolet absorption reagent in ion chromatography
    Liu, Yong-qiang
    Yu, Hong
    JOURNAL OF SEPARATION SCIENCE, 2017, 40 (08) : 1660 - 1666
  • [7] Ion chromatography with the indirect ultraviolet detection of alkali metal ions and ammonium using imidazolium ionic liquid as ultraviolet absorption reagent and eluent
    Liu, Yong-qiang
    Yu, Hong
    JOURNAL OF SEPARATION SCIENCE, 2016, 39 (16) : 3156 - 3162
  • [8] Rapid determination of N-methyl, propyl-morpholinium cation by ion-pair chromatography on monolithic column with indirect ultraviolet detection
    Sun Yimeng
    Yu Hong
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2013, 31 (10) : 969 - 973
  • [9] Rapid Determination of Pyrrolidinium Ionic Liquid Cations by Monolithic Column-Ion-pair Chromatography with Indirect Ultraviolet Detection
    An Ying
    Yu Hong
    Zou Chun-Miao
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 41 (07) : 1057 - 1062
  • [10] Imidazolium ionic liquid as the background ultraviolet absorption reagent for determination of morpholinium cations by high performance liquid chromatography-indirect ultraviolet detection
    Hong Yu
    Yi-Meng Sun
    Chun-Miao Zou
    Chinese Chemical Letters, 2014, 25 (10) : 1371 - 1374