Intrinsic dependencies of CT radiomic features on voxel size and number of gray levels

被引:446
作者
Shafiq-ul-Hassan, Muhammad [1 ,2 ]
Zhang, Geoffrey G. [1 ,2 ]
Latifi, Kujtim [1 ,2 ]
Ullah, Ghanim [1 ]
Hunt, Dylan C. [2 ]
Balagurunathan, Yoganand [2 ]
Abdalah, Mahmoud Abrahem [2 ]
Schabath, Matthew B. [2 ]
Goldgof, Dmitry G. [3 ]
Mackin, Dennis [4 ]
Court, Laurence Edward [4 ]
Gillies, Robert James [2 ]
Moros, Eduardo Gerardo [1 ,2 ]
机构
[1] Univ S Florida, Dept Phys, Tampa, FL 33620 USA
[2] H Lee Moffitt Canc Ctr & Res Inst, Tampa, FL 33612 USA
[3] Univ S Florida, Dept Comp Sci & Engn, Tampa, FL 33620 USA
[4] Univ Texas Houston, MD Anderson Canc Ctr, Dept Radiat Phys, 1515 Holcombe Blvd, Houston, TX 77030 USA
关键词
computed tomography; features; gray levels; phantom; radiomics; texture; voxel size; CELL LUNG-CANCER; TEXTURAL FEATURES; HETEROGENEITY QUANTIFICATION; TUMOR HETEROGENEITY; FRACTAL DIMENSION; PET IMAGES; VARIABILITY; CARCINOMA; DISCRETIZATION; ROBUSTNESS;
D O I
10.1002/mp.12123
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Many radiomics features were originally developed for non-medical imaging applications and therefore original assumptions may need to be reexamined. In this study, we investigated the impact of slice thickness and pixel spacing (or pixel size) on radiomics features extracted from Computed Tomography (CT) phantom images acquired with different scanners as well as different acquisition and reconstruction parameters. The dependence of CT texture features on gray-level discretization was also evaluated. Methods and materials: A texture phantom composed of 10 different cartridges of different materials was scanned on eight different CT scanners from three different manufacturers. The images were reconstructed for various slice thicknesses. For each slice thickness, the reconstruction Field Of View (FOV) was varied to render pixel sizes ranging from 0.39 to 0.98 mm. A fixed spherical region of interest (ROI) was contoured on the images of the shredded rubber cartridge and the 3D printed, 20% fill, acrylonitrile butadiene styrene plastic cartridge (ABS20) for all phantom imaging sets. Radiomic features were extracted from the ROIs using an in-house program. Features categories were: shape (10), intensity (16), GLCM (24), GLZSM (11), GLRLM (11), and NGTDM (5), fractal dimensions (8) and first-order wavelets (128), for a total of 213 features. Voxel-size resampling was performed to investigate the usefulness of extracting features using a suitably chosen voxel size. Acquired phantom image sets were resampled to a voxel size of 1 x 1 x 2 mm(3) using linear interpolation. Image features were therefore extracted from resampled and original datasets and the absolute value of the percent coefficient of variation (% COV) for each feature was calculated. Based on the % COV values, features were classified in 3 groups: (1) features with large variations before and after resampling (% COV >50); (2) features with diminished variation (% COV <30) after resampling; and (3) features that had originally moderate variation (% COV <50%) and were negligibly affected by resampling. Group 2 features were further studied by modifying feature definitions to include voxel size. Original and voxel-size normalized features were used for interscanner comparisons. A subsequent analysis investigated feature dependency on gray-level discretization by extracting 51 texture features from ROIs from each of the 10 different phantom cartridges using 16, 32, 64, 128, and 256 gray levels. Results: Out of the 213 features extracted, 150 were reproducible across voxel sizes, 42 improved significantly (% COV <30, Group 2) after resampling, and 21 had large variations before and after resampling (Group 1). Ten features improved significantly after definition modification effectively removed their voxel-size dependency. Interscanner comparison indicated that feature variability among scanners nearly vanished for 8 of these 10 features. Furthermore, 17 out of 51 texture features were found to be dependent on the number of gray levels. These features were redefined to include the number of gray levels which greatly reduced this dependency. Conclusion: Voxel-size resampling is an appropriate pre-processing step for image datasets acquired with variable voxel sizes to obtain more reproducible CT features. We found that some of the radiomics features were voxel size and gray-level discretization-dependent. The introduction of normalizing factors in their definitions greatly reduced or removed these dependencies. (C) 2017 American Association of Physicists in Medicine
引用
收藏
页码:1050 / 1062
页数:13
相关论文
共 41 条
  • [1] Aborisade D., 2014, Int. J. Comp. Trends Technol., V11, DOI [DOI 10.14445/22312803/IJCTT-V11P151, 10.14445/22312803/IJCTT-V11P151]
  • [2] Decoding tumour phenotype by noninvasive imaging using a quantitative radiomics approach
    Aerts, Hugo J. W. L.
    Velazquez, Emmanuel Rios
    Leijenaar, Ralph T. H.
    Parmar, Chintan
    Grossmann, Patrick
    Cavalho, Sara
    Bussink, Johan
    Monshouwer, Rene
    Haibe-Kains, Benjamin
    Rietveld, Derek
    Hoebers, Frank
    Rietbergen, Michelle M.
    Leemans, C. Rene
    Dekker, Andre
    Quackenbush, John
    Gillies, Robert J.
    Lambin, Philippe
    [J]. NATURE COMMUNICATIONS, 2014, 5
  • [3] TEXTURAL FEATURES CORRESPONDING TO TEXTURAL PROPERTIES
    AMADASUN, M
    KING, R
    [J]. IEEE TRANSACTIONS ON SYSTEMS MAN AND CYBERNETICS, 1989, 19 (05): : 1264 - 1274
  • [4] Basu S, 2011, IEEE SYS MAN CYBERN, P1306, DOI 10.1109/ICSMC.2011.6083840
  • [5] On some misconceptions about tumor heterogeneity quantification
    Brooks, Frank J.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 (08) : 1292 - 1294
  • [6] USE OF GRAY VALUE DISTRIBUTION OF RUN LENGTHS FOR TEXTURE ANALYSIS
    CHU, A
    SEHGAL, CM
    GREENLEAF, JF
    [J]. PATTERN RECOGNITION LETTERS, 1990, 11 (06) : 415 - 419
  • [7] Are Pretreatment 18F-FDG PET Tumor Textural Features in Non-Small Cell Lung Cancer Associated with Response and Survival After Chemoradiotherapy?
    Cook, Gary J. R.
    Yip, Connie
    Siddique, Muhammad
    Goh, Vicky
    Chicklore, Sugama
    Roy, Arunabha
    Marsden, Paul
    Ahmad, Shahreen
    Landau, David
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2013, 54 (01) : 19 - 26
  • [8] CT-based radiomic signature predicts distant metastasis in lung adenocarcinoma
    Coroller, Thibaud P.
    Grossmann, Patrick
    Hou, Ying
    Velazquez, Emmanuel Rios
    Leijenaar, Ralph T. H.
    Hermann, Gretchen
    Lambin, Philippe
    Haibe-Kains, Benjamin
    Mak, Raymond H.
    Aerts, Hugo J. W. L.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2015, 114 (03) : 345 - 350
  • [9] IMAGE CHARACTERIZATIONS BASED ON JOINT GRAY LEVEL RUN LENGTH DISTRIBUTIONS
    DASARATHY, BV
    HOLDER, EB
    [J]. PATTERN RECOGNITION LETTERS, 1991, 12 (08) : 497 - 502
  • [10] Exploring feature-based approaches in PET images for predicting cancer treatment outcomes
    El Naqa, I.
    Grigsby, P. W.
    Apte, A.
    Kidd, E.
    Donnelly, E.
    Khullar, D.
    Chaudhari, S.
    Yang, D.
    Schmitt, M.
    Laforest, Richard
    Thorstad, W. L.
    Deasy, J. O.
    [J]. PATTERN RECOGNITION, 2009, 42 (06) : 1162 - 1171