Tomographic three-dimensional position measurement of particles using a light field camera

被引:0
作者
Zhao Jun [1 ]
Gu Gaofei [1 ]
Kong Ming [1 ]
Guo Tiantai [1 ]
Wang Daodang [1 ]
机构
[1] China Jiliang Univ, Coll Metrol & Measurement Engn, Hangzhou 310018, Peoples R China
来源
PROCEEDINGS OF 2019 14TH IEEE INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS (ICEMI) | 2019年
基金
中国国家自然科学基金;
关键词
Light field camera; Ray tracing; Tomography; Particle localization;
D O I
10.1109/icemi46757.2019.9101453
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The tracing particle plays a key role in measuring velocity of flow field. The accuracy of tracing particle's spatial localization determines the accuracy of flow field velocity measurement. The traditional multi-camera technology for photographing tracing particles is costly and time consuming. A light field camera is used to collect particle images, and improves tomographic inversion algorithm to obtain the three-dimensional spatial position of particles faster and more accurately. Based on imaging principle of the light field camera system, a forward tracking model of light emitted by particles is established to realize the imaging simulation of particles. On the basis of this model, a tomographic inversion model is constructed to reversely trace the ray and realize the mapping between non-zero pixels and spatial voxels. A descending dimension method is proposed to calculate the weighting matrix. Multiplicative algebraic reconstruction technology is improved by combined with the similar triangle principle. The Gaussian Blob model is used to determine center position of the voxel with largest intensity value to obtain the three-dimensional position of particles. Experiments indicate that the improved MART algorithm which is used to perform three-dimensional inversion of particles can significantly increase calculation efficiency under the same accuracy level. It is more suitable for applications requiring high calculation speed. The x-axis coordinate error is +/- 0.06mm. The y-axis coordinate error is +/- 0.07mm. The z-axis coordinate error is +/- 0.58mm.
引用
收藏
页码:559 / 566
页数:8
相关论文
共 16 条
[1]   SINGLE LENS STEREO WITH A PLENOPTIC CAMERA [J].
ADELSON, EH ;
WANG, JYA .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1992, 14 (02) :99-106
[2]  
[Anonymous], 2012, THESIS
[3]  
Cao Lixia, 2017, Journal of Beijing University of Aeronautics and Astronautics, V43, P2322, DOI 10.13700/j.bh.1001-5965.2017.0068
[4]  
Duval G, 2005, Light field photography with a hand-held plenoptic cameraD, DOI DOI 10.1145/3097571
[5]   Tomographic particle image velocimetry [J].
Elsinga, G. E. ;
Scarano, F. ;
Wieneke, B. ;
van Oudheusden, B. W. .
EXPERIMENTS IN FLUIDS, 2006, 41 (06) :933-947
[6]  
Fahringer T., 2012, Fluid Dynamics and Co-located Conferences, DOI [DOI 10.2514/6.2012-2826, 10.2514/6.2012-2826]
[7]  
Fahringer T.W., 2014, AIAA, P1
[8]  
GAO Q, 2013, SCI B, V58, P4541, DOI DOI 10.1007/S11434-013-6081-Y
[9]  
Georgiev T., 2013, P SPIE INT SOC OPTIC, P8667
[10]  
Gershun A., 1939, J. Math. Phys., V18, P51, DOI [10.1002/sapm193918151, DOI 10.1002/SAPM193918151]