Reproducibility of kinematic motion coupling parameters during manual upper cervical axial rotation mobilization: A 3-dimensional in vitro study of the atlanto-axial joint

被引:16
作者
Cattrysse, E. [1 ]
Provyn, S. [1 ]
Kool, P. [2 ]
Gagey, O. [3 ]
Clarys, J. P. [1 ]
Van Roy, P. [1 ]
机构
[1] Vrije Univ Brussels, Fac Phys Educ & Physiotherapy, Dept Expt Anat, B-1090 Brussels, Belgium
[2] Vrije Univ Brussels, Fac Engn Sci, Dept Appl Mech, B-1090 Brussels, Belgium
[3] Univ Paris 05, Dept Anat, Paris 5, France
关键词
FASTRAK MEASUREMENT SYSTEM; LUMBAR SPINE; INTERTESTER RELIABILITY; HEALTHY-SUBJECTS; MEASURING RANGE; NECK PAIN; PALPATION; HEAD; MOVEMENTS; FLEXION;
D O I
10.1016/j.jelekin.2007.06.019
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Introduction: The reproducibility or the 3-dimensional (3D) kinematic aspects of motion coupling patterns of segmental manual mobilizing techniques is not yet known. This study analyzes the segmental 3D aspects of manual mobilization of the atlanto-axial joint in vitro. Methods and materials: Twenty fresh human cervical specimens were studied in a test retest situation with two examiners. The specimens were manually mobilized using three different techniques: a regional mobilization technique, it segmental mobilization technique on the atlas with manual fixation of the axis and a segmental mobilization applying a locking technique. Segmental kinematics were registered with a Zebris CMS20 ultrasound-based tracking system. The 3D aspects of motion coupling between main axial rotation and coupled lateral bending were analyzed by six parameters: the range of motion the three motion components, the cross-correlation, the ratio and the shift. Results: The results indicate stronger intra- than inter-examiner reproducibility. The range or motion of the axial rotation component shows a substantial level of intra- and inter-examiner reproducibility (ICC's 0.67 0.76). The parameters describing the coupling patterns show only moderate to substantial intra-examiner reproducibility for the more experienced of the two examiners (ICC's 0.55 0.68). All other correlations were not significant and no differences could be observed between regional versus segmental techniques. Conclusion: Reproducibility of segmental 3D-aspects of manual mobilization of the atlanto-axial joint in ail in vitro situation can differ between examiners. The results of the present study may indicate a possible tendency to higher reproducibility if mobilizations are performed by in examiner with high expertise and experience in applying the specific techniques. Continued investigation including more examiners with different levels of experience and different techniques is necessary to confirm these observations. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:93 / 104
页数:12
相关论文
共 63 条
  • [1] Measuring range of active cervical rotation in a position of full head flexion using the 3D Fastrak measurement system: an intra-tester reliability study
    Amiri, M
    Jull, G
    Bullock-Saxton, J
    [J]. MANUAL THERAPY, 2003, 8 (03) : 176 - 179
  • [2] Amiri M., 2003, J MAN MANIP THER, V11, P198, DOI DOI 10.1179/106698103790825528
  • [3] 3D kinematic analysis and clinical evaluation of neck movements in patients with whiplash injury
    Antonaci, F
    Bulgheroni, M
    Ghirmai, S
    Lanfranchi, S
    Dalla Toffola, E
    Sandrini, G
    Nappi, G
    [J]. CEPHALALGIA, 2002, 22 (07) : 533 - 542
  • [4] Measurement of three-dimensional intra-articular kinematics: methodological and interpretation problems
    Baeyens, JP
    Cattrysse, E
    Van Roy, P
    Clarys, JP
    [J]. ERGONOMICS, 2005, 48 (11-14) : 1638 - 1644
  • [5] Reproducibility and repeatability: errors of three groups of physiotherapists in locating spinal levels by palpation
    Billis, EV
    Foster, NE
    Wright, CC
    [J]. MANUAL THERAPY, 2003, 8 (04) : 223 - 232
  • [6] Posteroanterior motion test of a lumbar vertebra:: accuracy of perception
    Björnsdóttirt, SV
    Kumar, S
    [J]. DISABILITY AND REHABILITATION, 2003, 25 (4-5): : 170 - 178
  • [7] BREEN AC, 2006, BMC MUSCULOSKELET DI, V7
  • [8] CAPUANOPUCCI D, 1991, ARCH PHYS MED REHAB, V72, P338
  • [9] A protocol for the assessment of 3D movements of the head in persons with cervical dystonia
    Carpaneto, J
    Micera, S
    Galardi, G
    Micheli, A
    Carboncini, MC
    Rossi, B
    Dario, P
    [J]. CLINICAL BIOMECHANICS, 2004, 19 (07) : 659 - 663
  • [10] CATTRYSSE E, 1997, MANUAL THERAPY, V2, P91