Reference optimization for a common-path optical coherence tomography probe using angle polishing

被引:0
|
作者
Liu, Xuan [1 ]
Kang, Jin U. [2 ]
机构
[1] Michigan Technol Univ, Dept Biomed Engn, 1400 Townsend Dr, Houghton, MI 49931 USA
[2] Johns Hopkins Univ, Dept Elect & Comp Engn, Baltimore, MD 21218 USA
关键词
Optical coherence tomography; Fiber optics imaging; Endoscopic imaging;
D O I
10.1117/12.2038188
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In this study, we polished the tip of single mode fiber to an angle that optimizes the reference power of a common-path optical coherence tomography (CP OCT) system. OCT images obtained with optimized reference show significantly improved signal to noise ratio.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Long-range common-path spectral domain optical coherence tomography
    Wang, Chen
    Zhang, Qiankun
    Wang, Yimin
    Zhang, Xiangyang
    Zhang, Linna
    OPTICS EXPRESS, 2019, 27 (09): : 12483 - 12490
  • [22] In-fiber common-path optical coherence tomography using a conical-tip fiber
    Tan, K. M.
    Mazilu, M.
    Chow, T. H.
    Lee, W. M.
    Taguchi, K.
    Ng, B. K.
    Sibbett, W.
    Herrington, C. S.
    Brown, C. T. A.
    Dholakia, K.
    OPTICS EXPRESS, 2009, 17 (04): : 2375 - 2384
  • [23] Common-Path Fourier-Domain Optical Coherence Tomography in Ophthalmology Applications
    Han, Jae-Ho
    Liu, Xuan
    Zhang, Kang
    Kang, Jin U.
    2009 IEEE/NIH LIFE SCIENCE SYSTEMS AND APPLICATIONS WORKSHOP, 2009, : 163 - 166
  • [24] Endoscopic Functional Fourier Domain Common-Path Optical Coherence Tomography for Microsurgery
    Kang, Jin U.
    Han, Jae-Ho
    Liu, Xuan
    Zhang, Kang
    Song, Chul Gyu
    Gehlbach, Peter
    IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2010, 16 (04) : 781 - 792
  • [25] Handheld common-path swept-source optical coherence tomography angiography
    Chang, Yu-Huan
    Chen, Chen-Yi
    Kuo, Wen-Chuan
    OPTICS LETTERS, 2023, 48 (15) : 3913 - 3916
  • [26] Astigmatism Corrected Common Path Probe for Optical Coherence Tomography
    Singh, Kanwarpal
    Yamada, Daisuke
    Tearney, Guillermo
    LASERS IN SURGERY AND MEDICINE, 2017, 49 (03) : 312 - 318
  • [27] Common path optical coherence tomography with fibre bundle probe
    Han, J. -H.
    Liu, X.
    Song, C. G.
    Kang, J. U.
    ELECTRONICS LETTERS, 2009, 45 (22) : 1110 - 1111
  • [28] Common-Path Optical Coherence Tomography Using the Bessel Beam From Negative Axicon Optical Fiber Tip
    Vairagi, Kaushal
    Pandey, Amit
    Gupta, Pooja
    Minz, Rashmi A.
    Tiwari, Umesh K.
    Fick, Jochen
    Mondal, Samir K.
    IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2019, 25 (01)
  • [29] Comparison of different focusing systems for common-path optical coherence tomography with fiber-optic bundle as endoscopic probe
    Wang, Weichao
    Zhang, Kang
    Ren, Qiushi
    Kang, Jin U.
    OPTICAL ENGINEERING, 2009, 48 (10)
  • [30] Handheld optical coherence tomography scanner using a common-path probing arm with long working distance
    Zhou, Song
    Yang, Wen
    Wang, Yimin
    Chen, Zhong
    Yuan, Tianran
    OPTICS COMMUNICATIONS, 2021, 499