Coronary angiography using a portable super-C-arm imaging system in a district general hospital

被引:0
作者
Chua, TP [1 ]
Sarkar, D [1 ]
Leatham, EW [1 ]
Webb-Peploe, MM [1 ]
机构
[1] Royal Surrey Cty Hosp, Dept Cardiol, Surrey GU2 7XX, England
关键词
coronary angiography; super-C-arm; district general hospital;
D O I
10.1016/j.ijcard.2003.03.011
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: New generation portable super-C-arm imaging systems may offer an alternative means of performing coronary angiography at a lower cost compared with a fixed laboratory. We evaluated the use of one such system (GE-OEC 9800) in a district hospital setting. Methods: The demographics, procedure and screening times, emitted radiation dose and diagnoses of the first 200 consecutive patients were obtained from a prospective database. Comparison between the portable and fixed systems were made by analysing results from similar cohorts of patients who underwent angiography by the same operators. Image quality was assessed in 23 patients, by an independent cardiologist, comparing the GE-OEC 9800 angiograms with repeat images using a fixed laboratory Philips (HM 3000) system within 3 months of the first study. Results: The procedure time (mean (S.D.)) was 18.9 (0.8) min for the 200 cases. The screening time was 255 (15) s with an emitted radiation of 22.8 (1.4) Gy/cm(2). Comparison between the C-arm and fixed systems revealed significantly longer screening time (230.6 (14.6) vs. 157 (12.9) s, p < 0.001), whilst the total radiation doses were not significantly different (21.1 (1.5) vs. 18.6 (1.11) Gy/cm(2)). Independently assessed image quality was satisfactory. The main variance in 57 lesions seen in the 23 patients using the angiograms obtained from the fixed laboratory as reference included overestimated stenosis (two lesions), underestimated stenosis (or subsequent disease progression) (four lesions), lack of appreciation of side-branch ostial involvement (two lesions) and vessel calcification (one lesion). Conclusions: Portable imaging systems can offer a reliable and cost-effective diagnostic coronary angiography service in a district hospital. (C) 2004 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:173 / 176
页数:4
相关论文
共 7 条
[1]  
ALLABADI D, 1997, CATHETER CARDIOVASC, V41, P449
[2]  
CAROSIO G, 1998, ITAL CARDIOL, V28, P979
[3]   On "Experience with a portable digital C-arm system for cardiac catheterization and intervention" [J].
Goldstein, JA .
JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2000, 13 (02) :81-81
[4]   Diagnostic cardiac catheterisation in a hospital without on-site cardiac surgery [J].
Papaconstantinou, HD ;
Marshall, AJ ;
Burrell, CJ .
HEART, 1999, 81 (05) :465-469
[5]   GUIDELINES FOR PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY - A REPORT OF THE AMERICAN-HEART-ASSOCIATION AMERICAN-COLLEGE-OF-CARDIOLOGY TASK-FORCE ON ASSESSMENT OF DIAGNOSTIC AND THERAPEUTIC CARDIOVASCULAR PROCEDURES (COMMITTEE ON PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY) [J].
RYAN, TJ ;
BAUMAN, WB ;
KENNEDY, JW ;
KEREIAKES, DJ ;
KING, SB ;
MCCALLISTER, BD ;
SMITH, SC ;
ULLYOT, DJ .
CIRCULATION, 1993, 88 (06) :2987-3007
[6]   Audit of cardiac catheterisation in a district general hospital: implications for training [J].
Smith, LDR ;
Spyer, G ;
Dean, JW .
HEART, 1999, 81 (05) :461-464
[7]   Experience with a portable digital C-arm system for cardiac catheterization and intervention [J].
Sullebarger, JT ;
Mazion, D ;
Courey, M ;
Sayad, D ;
Siddique, M ;
Fontanet, H ;
Matar, F ;
Cintron, G .
JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2000, 13 (02) :83-86