Improved myoelectric prosthesis control accomplished using multiple nerve transfers

被引:110
作者
Hijjawi, John B.
Kuiken, Todd A.
Lipschutz, Robert D.
Miller, Laura A.
Stubblefield, Kathy A.
Dumanian, Gregory A.
机构
[1] Northwestern Univ, Div Plast Surg, Dept Surg, Chicago, IL 60610 USA
[2] Northwestern Univ, Dept Phys Med & Rehabil, Feinberg Sch Med, Chicago, IL 60610 USA
[3] Rehabil Inst Chicago, Neural Engn Ctr Artif Limbs, Chicago, IL 60611 USA
关键词
D O I
10.1097/01.prs.0000242487.62487.fb
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: The control of shoulder-level disarticulation prostheses is significantly more difficult than that of prostheses for more distal amputations. Amputees have significant difficulties coordinating the separate functions of prosthetic shoulder, elbow, wrist, and hand/hook components. The user must lock one joint at a particular position in space before subsequently moving a different joint. Methods: A patient with bilateral humeral disarticulations after an electrical injury underwent a novel nerve transfer procedure designed to improve the control of a myoelectric prosthesis. The median, radial, ulnar, and musculocutaneous nerves were transferred to the nerves of segments of the pectoralis major and minor muscles. Those muscles then act as bioamplifiers of peripheral nerve signals when the normal upper extremity nerves are activated by the patient's brain. Therefore, when the patient thinks "flex elbow," the transferred musculocutaneous; nerve fires, and a segment of the pectoralis major contracts. An electromyographic signal is then detected transcutaneously and causes the prosthetic elbow to flex. Results: Three of the four nerve transfers were successful. One of the nerve transfers unexpectedly yielded two separate controllable muscle segments. Standardized testing using a "box-and-blocks" apparatus was performed with the patient's previous myoelectric device and the current device after nerve transfers. The patient's performance improved by 246 percent. Conclusions: Nerve transfers to small muscle segments are capable of creating a novel neural inter-face for improved control of a myoelectric prosthesis. This is done using standard techniques of nerve and flap surgery, and without any implantable devices.
引用
收藏
页码:1573 / 1578
页数:6
相关论文
共 10 条
[1]   The anatomy of the pectoral nerves and their significance in brachial plexus reconstruction [J].
Aszmann, OC ;
Rab, M ;
Kamolz, L ;
Frey, M .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2000, 25A (05) :942-947
[2]   The nerve supply to the clavicular part of the pectoralis major muscle: An anatomical study and clinical application of the function-preserving pectoralis major island flap [J].
Corten, EML ;
Schellekens, PPA ;
Bleys, RLAW ;
Kon, M .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2003, 112 (04) :969-975
[3]  
Hoffer JA, 1996, J REHABIL RES DEV, V33, P145
[4]   THE ANATOMY OF THE PECTORAL NERVES AND ITS SIGNIFICANCE TO THE GENERAL AND PLASTIC SURGEON [J].
HOFFMAN, GW ;
ELLIOTT, LF .
ANNALS OF SURGERY, 1987, 205 (05) :504-507
[5]  
Kuiken TA, 2004, PROSTHET ORTHOT INT, V28, P245
[6]  
Kuiken TA, 2003, PROSTHET ORTHOT INT, V27, P48
[7]   THE HYPER-REINNERVATION OF RAT SKELETAL-MUSCLE [J].
KUIKEN, TA ;
CHILDRESS, DS ;
RYMER, WZ .
BRAIN RESEARCH, 1995, 676 (01) :113-123
[8]   Independence of myoelectric control signals examined using a surface EMG model [J].
Lowery, MM ;
Stoykov, NS ;
Kuiken, TA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2003, 50 (06) :789-793
[9]   ADULT NORMS FOR THE BOX AND BLOCK TEST OF MANUAL DEXTERITY [J].
MATHIOWETZ, V ;
VOLLAND, G ;
KASHMAN, N ;
WEBER, K .
AMERICAN JOURNAL OF OCCUPATIONAL THERAPY, 1985, 39 (06) :386-391