Dry contact electrodes performance in canine ECG

被引:2
作者
Virtanen, Juhani [1 ,2 ]
Leivo, Joni [1 ,2 ]
Vehkaoja, Antti [1 ,2 ]
Somppi, Sanni [3 ]
Tornqvist, Heini [3 ]
Fiedler, Patrique [4 ]
Vaataja, Heli [5 ]
Surakka, Veikko [5 ]
机构
[1] Univ Tampere, BioMediTech Inst, Tampere, Finland
[2] Univ Tampere, Fac Biomed Sci & Engn, Tampere, Finland
[3] Univ Helsinki, Dept Equine & Small Anim Med, Helsinki, Finland
[4] Tech Univ Ilmenau, Inst Biomed Engn & Informat, Ilmenau, Germany
[5] Univ Tampere UTA, Res Grp Emot Social & Comp, Fac Commun Sci, Tampere, Finland
来源
FIFTH INTERNATIONAL CONFERENCE ON ANIMAL-COMPUTER INTERACTION (ACI 2018) | 2018年
关键词
Canine; Electrocardiogram; Dry Electrode; HEART-RATE-VARIABILITY;
D O I
10.1145/3295598.3295609
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Measuring the heart rate of animals is an important area of research which can be applied to numerous analyses. In this work we evaluate the performance of two dry contact electrocardiogram (ECG) electrode structures for monitoring the heart rate of domestic pets. The aim was to improve the operation of previously evaluated electrodes with some modifications. First, the thirty-pins of a previously studied polymer electrode with a silver/silver chloride (Ag/AgCl) coating were reduced to 12. Second, a 12-pin gold-plated metal electrode was coated with poly (3,4 ethylenedioxythiophene) polystyrene sulfonate (PEDOT: PSS). These electrodes were attached to a specifically designed measurement harness and the performance of the electrodes was evaluated in terms of heartbeat detection coverage. The heart rate coverage was measured during four different behaviors: standing, sitting, lying, and walking (N=27/activity). The results were, in general, comparable to the previously reported performance but having fewer pins on a polymer electrode seemed to cause more variation in the coverage values. However, when measures such as the median value of the coverages are considered, there was no obvious difference, especially when the coverage values were observed altogether. Thus, new electrode solutions are worthy of further research.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] PEDOT:PSS Hydrogel based Flexible Electrodes for Wearable ECG Monitoring
    Xu, Shiyi
    Li, Tianyu
    Ren, Hangxu
    Mao, Xiyu
    Ye, Xuesong
    Liang, Bo
    2020 IEEE SENSORS, 2020,
  • [42] ECG-Based Real-Time Drivers' Fatigue Detection Using a Novel Elastic Dry Electrode
    Wang, Fuwang
    Yao, Wanchao
    Lu, Bin
    Fu, Rongrong
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73 : 1 - 16
  • [43] Characterization and Validation of Flexible Dry Electrodes for Wearable Integration
    Nunes, Tiago
    da Silva, Hugo Placido
    SENSORS, 2023, 23 (03)
  • [44] Efficacy of Various Dry Electrode-Based ECG Sensors: A Review
    Kumar, Ghanshyam
    Duggal, Bhanu
    Singh, J. P.
    Shrivastava, Yash
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2025, 113 (01)
  • [45] A Wearable ECG Monitoring System Using Microneedle Electrodes for Small Animals
    Kim, Chaehyun
    Jang, Ahram
    Kim, Sebin
    Cho, Sungbo
    Lee, Donghun
    Kim, Young-Joon
    IEEE SENSORS JOURNAL, 2023, 23 (18) : 21873 - 21881
  • [46] Stretchable Ag/AgCl Nanowire Dry Electrodes for High-Quality Multimodal Bioelectronic Sensing
    Wang, Tianyu
    Yao, Shanshan
    Shao, Li-Hua
    Zhu, Yong
    SENSORS, 2024, 24 (20)
  • [47] A Low-power Dry Electrode-based ECG Signal Acquisition with De-noising and Feature Extraction
    Deepa Kota
    Nishat Tasneem
    Karthik Kakaraparty
    Ifana Mahbub
    Gayatri Mehta
    Kamesh Namuduri
    Journal of Signal Processing Systems, 2022, 94 : 579 - 593
  • [48] A Low-power Dry Electrode-based ECG Signal Acquisition with De-noising and Feature Extraction
    Kota, Deepa
    Tasneem, Nishat
    Kakaraparty, Karthik
    Mahbub, Ifana
    Mehta, Gayatri
    Namuduri, Kamesh
    JOURNAL OF SIGNAL PROCESSING SYSTEMS FOR SIGNAL IMAGE AND VIDEO TECHNOLOGY, 2022, 94 (06): : 579 - 593
  • [49] Analysis of Consistency of Transthoracic Bioimpedance Measurements Acquired with Dry Carbon Black PDMS Electrodes, Adhesive Electrodes, and Wet Textile Electrodes
    Posada-Quintero, Hugo F.
    Reljin, Natasa
    Eaton-Robb, Caitlin
    Noh, Yeonsik
    Riistama, Jarno
    Chon, Ki H.
    SENSORS, 2018, 18 (06)
  • [50] Non-contact capacitive sensing for ECG recording in small animals
    Wang, Ting-Wei
    Lin, Shien-Fong
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2020, 31 (12)