Dry contact electrodes performance in canine ECG

被引:2
作者
Virtanen, Juhani [1 ,2 ]
Leivo, Joni [1 ,2 ]
Vehkaoja, Antti [1 ,2 ]
Somppi, Sanni [3 ]
Tornqvist, Heini [3 ]
Fiedler, Patrique [4 ]
Vaataja, Heli [5 ]
Surakka, Veikko [5 ]
机构
[1] Univ Tampere, BioMediTech Inst, Tampere, Finland
[2] Univ Tampere, Fac Biomed Sci & Engn, Tampere, Finland
[3] Univ Helsinki, Dept Equine & Small Anim Med, Helsinki, Finland
[4] Tech Univ Ilmenau, Inst Biomed Engn & Informat, Ilmenau, Germany
[5] Univ Tampere UTA, Res Grp Emot Social & Comp, Fac Commun Sci, Tampere, Finland
来源
FIFTH INTERNATIONAL CONFERENCE ON ANIMAL-COMPUTER INTERACTION (ACI 2018) | 2018年
关键词
Canine; Electrocardiogram; Dry Electrode; HEART-RATE-VARIABILITY;
D O I
10.1145/3295598.3295609
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Measuring the heart rate of animals is an important area of research which can be applied to numerous analyses. In this work we evaluate the performance of two dry contact electrocardiogram (ECG) electrode structures for monitoring the heart rate of domestic pets. The aim was to improve the operation of previously evaluated electrodes with some modifications. First, the thirty-pins of a previously studied polymer electrode with a silver/silver chloride (Ag/AgCl) coating were reduced to 12. Second, a 12-pin gold-plated metal electrode was coated with poly (3,4 ethylenedioxythiophene) polystyrene sulfonate (PEDOT: PSS). These electrodes were attached to a specifically designed measurement harness and the performance of the electrodes was evaluated in terms of heartbeat detection coverage. The heart rate coverage was measured during four different behaviors: standing, sitting, lying, and walking (N=27/activity). The results were, in general, comparable to the previously reported performance but having fewer pins on a polymer electrode seemed to cause more variation in the coverage values. However, when measures such as the median value of the coverages are considered, there was no obvious difference, especially when the coverage values were observed altogether. Thus, new electrode solutions are worthy of further research.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Continuous control systems for non-contact ECG
    Kodkin, Vladimir L.
    Yakovleva, Galina V.
    Smirnov, Alexey S.
    DESIGN AND QUALITY FOR BIOMEDICAL TECHNOLOGIES X, 2017, 10056
  • [32] DESIGNING OF A SINGLE ARM SINGLE LEAD ECG SYSTEM FOR WET AND DRY ELECTRODE: A COMPARISON WITH TRADITIONAL SYSTEM
    Gautham, A.
    Raj, Karthik, V
    BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2016, 28 (03):
  • [33] Performance Evaluation of Time-Frequency Distributions for ECG Signal Analysis
    Hussein, Ahmed Faeq
    Hashim, Shaiful Jahari
    Aziz, Ahmad Fazli Abdul
    Rokhani, Fakhrul Zaman
    Adnan, Wan Azizun Wan
    JOURNAL OF MEDICAL SYSTEMS, 2018, 42 (01)
  • [34] Multichannel EEG with novel Ti/TiN dry electrodes
    Fiedler, P.
    Griebel, S.
    Pedrosa, P.
    Fonseca, C.
    Vaz, F.
    Zentner, L.
    Zanow, F.
    Haueisen, J.
    SENSORS AND ACTUATORS A-PHYSICAL, 2015, 221 : 139 - 147
  • [35] Materials for Dry Electrodes for the Electroencephalography: Advances, Challenges, Perspectives
    Yang, Liangtao
    Liu, Qing
    Zhang, Zhilin
    Gan, Lu
    Zhang, Yi
    Wu, Jinglong
    ADVANCED MATERIALS TECHNOLOGIES, 2022, 7 (03):
  • [36] Presetting ECG electrodes for earlier heart rate detection in the delivery room
    Gulati, Rashmi
    Zayek, Michael
    Eyal, Fabien
    RESUSCITATION, 2018, 128 : 83 - 87
  • [37] Potato peels-based electrodes for recording ECG and EMG signals
    Stojanovic, Goran M.
    Popovic, Zeljko
    Milic, Lazar
    Simic, Mitar
    SENSING AND BIO-SENSING RESEARCH, 2024, 44
  • [38] Review of semi-dry electrodes for EEG recording
    Li, Guang-Li
    Wu, Jing-Tao
    Xia, Yong-Hui
    He, Quan-Guo
    Jin, Hong-Guang
    JOURNAL OF NEURAL ENGINEERING, 2020, 17 (05)
  • [39] Investigation of fetal ECG signal using textile-based electrodes
    Aghadavod, Roya
    Zarrebini, Mohammad
    Shanbeh, Mohsen
    Shayegh, Farzaneh
    Sabet, Fahimeh
    JOURNAL OF THE TEXTILE INSTITUTE, 2024, 115 (01) : 29 - 40
  • [40] Design and Characterization of Screen-Printed Textile Electrodes for ECG Monitoring
    Achilli, Andrea
    Bonfiglio, Annalisa
    Pani, Danilo
    IEEE SENSORS JOURNAL, 2018, 18 (10) : 4097 - 4107