Dry contact electrodes performance in canine ECG

被引:2
|
作者
Virtanen, Juhani [1 ,2 ]
Leivo, Joni [1 ,2 ]
Vehkaoja, Antti [1 ,2 ]
Somppi, Sanni [3 ]
Tornqvist, Heini [3 ]
Fiedler, Patrique [4 ]
Vaataja, Heli [5 ]
Surakka, Veikko [5 ]
机构
[1] Univ Tampere, BioMediTech Inst, Tampere, Finland
[2] Univ Tampere, Fac Biomed Sci & Engn, Tampere, Finland
[3] Univ Helsinki, Dept Equine & Small Anim Med, Helsinki, Finland
[4] Tech Univ Ilmenau, Inst Biomed Engn & Informat, Ilmenau, Germany
[5] Univ Tampere UTA, Res Grp Emot Social & Comp, Fac Commun Sci, Tampere, Finland
来源
FIFTH INTERNATIONAL CONFERENCE ON ANIMAL-COMPUTER INTERACTION (ACI 2018) | 2018年
关键词
Canine; Electrocardiogram; Dry Electrode; HEART-RATE-VARIABILITY;
D O I
10.1145/3295598.3295609
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Measuring the heart rate of animals is an important area of research which can be applied to numerous analyses. In this work we evaluate the performance of two dry contact electrocardiogram (ECG) electrode structures for monitoring the heart rate of domestic pets. The aim was to improve the operation of previously evaluated electrodes with some modifications. First, the thirty-pins of a previously studied polymer electrode with a silver/silver chloride (Ag/AgCl) coating were reduced to 12. Second, a 12-pin gold-plated metal electrode was coated with poly (3,4 ethylenedioxythiophene) polystyrene sulfonate (PEDOT: PSS). These electrodes were attached to a specifically designed measurement harness and the performance of the electrodes was evaluated in terms of heartbeat detection coverage. The heart rate coverage was measured during four different behaviors: standing, sitting, lying, and walking (N=27/activity). The results were, in general, comparable to the previously reported performance but having fewer pins on a polymer electrode seemed to cause more variation in the coverage values. However, when measures such as the median value of the coverages are considered, there was no obvious difference, especially when the coverage values were observed altogether. Thus, new electrode solutions are worthy of further research.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Conformal Dry Electrode for ECG Monitoring
    Al-Haidari, Riadh
    Falola, Babatunde
    Alhendi, Mohammed
    Schadt, Mark J.
    Poliks, Mark
    Balder, Daniel
    Stemmermann, Andrew
    Foster, Matthew
    Baichand, Veerendra
    Kao, Tzu-Jen
    Stoffel, Nancy
    PROCEEDINGS OF THE IEEE 74TH ELECTRONIC COMPONENTS AND TECHNOLOGY CONFERENCE, ECTC 2024, 2024, : 1662 - 1669
  • [22] A performance evaluation of silver nanorods PDMS flexible dry electrodes for electrocardiogram monitoring
    C. M. Vidhya
    Ghanshyam Kumar
    Yogita Maithani
    Bhanu Duggal
    J. P. Singh
    Scientific Reports, 15 (1)
  • [23] Highly conformable stretchable dry electrodes based on inexpensive flex substrate for long-term biopotential (EMG/ECG) monitoring
    Shahandashti, Peyman Fayyaz
    Pourkheyrollah, Hamed
    Jahanshahi, Amir
    Ghafoorifard, Hassan
    SENSORS AND ACTUATORS A-PHYSICAL, 2019, 295 : 678 - 686
  • [24] Electrical performance of PEDOT: PSS-based textile electrodes for wearable ECG monitoring: a comparative study
    Castrillon, Reinel
    Perez, Jairo J.
    Andrade-Caicedo, Henry
    BIOMEDICAL ENGINEERING ONLINE, 2018, 17
  • [25] ECG Measurement by Use of Passive Capacitively Coupled Electrodes
    Kirchner, Jens
    Roth, Nils
    Meyer, Andreas
    Fischer, Georg
    2016 IEEE SENSORS, 2016,
  • [26] Exploration of AgNW/PU nanoweb as ECG textile electrodes and comparison with Ag/AgCl electrodes
    Lee, Eugene
    Kim, Inhwan
    Liu, Hang
    Cho, Gilsoo
    FIBERS AND POLYMERS, 2017, 18 (09) : 1749 - 1753
  • [27] High-performance, water-resistant and ion-conducting gel used as underwater ECG electrodes
    Shi, Yufei
    Ding, Yuefei
    Wang, Wei
    Yu, Dan
    JOURNAL OF MATERIALS SCIENCE, 2023, 58 (42) : 16415 - 16427
  • [28] An ECG Acquisition System Prototype Design With Flexible PDMS Dry Electrodes and Variable Transform Length DCT-IV Based Compression Algorithm
    Luo, Ching-Hsing
    Ma, Wei-Jhe
    Juang, Wen-Ho
    Kuo, Shin-Hung
    Chen, Chih-Yuan
    Tai, Pei-Chen
    Lai, Shin-Chi
    IEEE SENSORS JOURNAL, 2016, 16 (23) : 8244 - 8254
  • [29] Dry Electrodes for Capturing Brain Electrical Signals
    Ferreira, Luiz G.
    Pimenta, Tales C.
    2024 31ST INTERNATIONAL CONFERENCE ON MIXED DESIGN OF INTEGRATED CIRCUITS AND SYSTEM, MIXDES 2024, 2024, : 290 - 293
  • [30] Dielectrics for Non-Contact ECG Bioelectrodes: A Review
    Umar, Alhassan Haruna
    Othman, Mohd Afzan
    Harun, Fauzan Khairi Che
    Yusof, Yusmeeraz
    IEEE SENSORS JOURNAL, 2021, 21 (17) : 18353 - 18367