Dry contact electrodes performance in canine ECG

被引:2
|
作者
Virtanen, Juhani [1 ,2 ]
Leivo, Joni [1 ,2 ]
Vehkaoja, Antti [1 ,2 ]
Somppi, Sanni [3 ]
Tornqvist, Heini [3 ]
Fiedler, Patrique [4 ]
Vaataja, Heli [5 ]
Surakka, Veikko [5 ]
机构
[1] Univ Tampere, BioMediTech Inst, Tampere, Finland
[2] Univ Tampere, Fac Biomed Sci & Engn, Tampere, Finland
[3] Univ Helsinki, Dept Equine & Small Anim Med, Helsinki, Finland
[4] Tech Univ Ilmenau, Inst Biomed Engn & Informat, Ilmenau, Germany
[5] Univ Tampere UTA, Res Grp Emot Social & Comp, Fac Commun Sci, Tampere, Finland
来源
FIFTH INTERNATIONAL CONFERENCE ON ANIMAL-COMPUTER INTERACTION (ACI 2018) | 2018年
关键词
Canine; Electrocardiogram; Dry Electrode; HEART-RATE-VARIABILITY;
D O I
10.1145/3295598.3295609
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Measuring the heart rate of animals is an important area of research which can be applied to numerous analyses. In this work we evaluate the performance of two dry contact electrocardiogram (ECG) electrode structures for monitoring the heart rate of domestic pets. The aim was to improve the operation of previously evaluated electrodes with some modifications. First, the thirty-pins of a previously studied polymer electrode with a silver/silver chloride (Ag/AgCl) coating were reduced to 12. Second, a 12-pin gold-plated metal electrode was coated with poly (3,4 ethylenedioxythiophene) polystyrene sulfonate (PEDOT: PSS). These electrodes were attached to a specifically designed measurement harness and the performance of the electrodes was evaluated in terms of heartbeat detection coverage. The heart rate coverage was measured during four different behaviors: standing, sitting, lying, and walking (N=27/activity). The results were, in general, comparable to the previously reported performance but having fewer pins on a polymer electrode seemed to cause more variation in the coverage values. However, when measures such as the median value of the coverages are considered, there was no obvious difference, especially when the coverage values were observed altogether. Thus, new electrode solutions are worthy of further research.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Novel dry electrodes for ECG monitoring
    Gruetzmann, Anna
    Hansen, Stefan
    Mueller, Joerg
    PHYSIOLOGICAL MEASUREMENT, 2007, 28 (11) : 1375 - 1390
  • [2] A Low-Power Portable ECG Touch Sensor with Two Dry Metal Contact Electrodes
    Yan, Long
    Yoo, Hoi-Jun
    JOURNAL OF SEMICONDUCTOR TECHNOLOGY AND SCIENCE, 2010, 10 (04) : 300 - 308
  • [3] Contact ECG Recording Using Copper and E-Textile Based Flexible Dry Electrodes
    Ren, Kai
    Ma, Ruyu
    Nikkhah, Mohammad R.
    Eggleston, Steve
    Ren, Yu-Jiun
    Behdad, Nader
    PROGRESS IN ELECTROMAGNETICS RESEARCH M, 2021, 101 : 47 - 58
  • [4] MWCNT-COOH/PDMS based dry ECG electrodes for ambulatory ECG recordings
    Gandhi, Bani
    Raghava, N. S.
    MATERIALS LETTERS, 2022, 307
  • [5] Evaluation of Dry Electrodes in Canine Heart Rate Monitoring
    Virtanen, Juhani
    Somppi, Sanni
    Tornqvist, Heini
    Jeyhani, Vala
    Fiedler, Patrique
    Gizatdinova, Yulia
    Majaranta, Paivi
    Vaataja, Heli
    Cardo, Anna Valldeoriola
    Lekkala, Jukka
    Tuukkanen, Sampo
    Surakka, Veikko
    Vainio, Outi
    Vehkaoja, Antti
    SENSORS, 2018, 18 (06)
  • [6] A low-power portable ECG sensor interface with dry electrodes
    浦小飞
    万磊
    张辉
    秦亚杰
    洪志良
    Journal of Semiconductors, 2013, (05) : 104 - 109
  • [7] Skin-Potential Variation Insensitive Dry Electrodes for ECG Recording
    Pei, Weihua
    Zhang, He
    Wang, Yijun
    Guo, Xuhong
    Xing, Xiao
    Huang, Yong
    Xie, Yuxing
    Yang, Xiaowei
    Chen, Hongda
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2017, 64 (02) : 463 - 470
  • [8] A low-power portable ECG sensor interface with dry electrodes
    Pu Xiaofei
    Wan Lei
    Zhang Hui
    Qin Yajie
    Hong Zhiliang
    JOURNAL OF SEMICONDUCTORS, 2013, 34 (05)
  • [9] Performance of graphene ECG electrodes under varying conditions
    Beach, Christopher
    Karim, Nazmul
    Casson, Alexander J.
    2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 3813 - 3816
  • [10] Reusable, Cased and Mechanically Held Graphite-Based Dry ECG Electrodes
    Soto Dominguez, Rodrigo
    Anguiano Pina, Uriel
    Reyes, Bersain A.
    VIII LATIN AMERICAN CONFERENCE ON BIOMEDICAL ENGINEERING AND XLII NATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, 2020, 75 : 1085 - 1092